Sürdürülebilir Kalkınma Amaçları
Yazarlar
- Duran, Celal(12)
- Ozdes, Duygu(10)
- Bulut, Volkan Numan(6)
- Soylak, Mustafa(6)
- Serencam, Huseyin(5)
- Bektas, Hakan(4)
- Tufekci, Mehmet(4)
- Elvan, Hamide(2)
- Gundogdu, Ali(2)
- Akcay, Hakki Turker(1)
- Altunay, Nail(1)
- Bahadir, Zekeriyya(1)
- Bahadır, Zekeriyya(1)
- Basri Senturk, Hasan(1)
- Bayrak, Hacer(1)
- Bekircan, Olcay(1)
- Bektaş, Hakan(1)
- Camoglu, Aslihan Yilmaz(1)
- Elik, Adil(1)
- Hamza, Sibel(1)
- Kantekin, Halit(1)
- Karakoy, Tolga(1)
- Sahin, Deniz(1)
- Tumay, Sureyya O.(1)
- Tüfekçi, Mehmet(1)
- Çelenk Kaya, Elif(1)
- Çilesiz, Yeter(1)
- Özdeş, Duygu(1)
Yayınlar
- MakaleAçık Erişim2023Scopus SJRQ2A green and simplified approach for the quantitative and sensitive analysis of heavy metal ions in sea and stream waters
Duran, Celal; Camoglu, Aslihan Yilmaz; Ozdes, Duygu; Bekircan, Olcay
Elimination of the matrix effect is a major challenge in developing a method for the quantification of heavy metals (HMs) in water samples. In this regard, the current research describes the simultaneous analyses of Cu(II), Cd(II), and Ni(II) ions in water matrices through flame atomic absorption spectrophotometry (FAAS) after preconcentration with carrier element-free co-precipitation (CEFC) technique by the help of an organic co-precipitant, 3-{[5-(4-Chlorobenzyl)-3-(4-chlorophenyl)-1H-1,2,4-triazol-1-yl]-methyl}-4-[2,4-(dichlorobenzylidene)amino]-1H-1,2,4- triazole-5(4H)-thione (CCMBATT). Based on our literature research, CCMBATT was employed for the first time in this study as an organic co-precipitant for the preconcentration of HMs. Factors such as solution pH, concentration of co-precipitant, sample volume, standing time, centrifugation rate, and time were thoroughly examined and optimized to achieve the highest efficiency in terms of HM recovery. The limits of detection (LODs) (with 10 number of tests) of 0.54, 0.34, and 1.95 μg L-1 and the relative standard deviations (RSD %) of 2.1, 3.3, and 3.0 were determined for Cu(II), Cd(II) and Ni(II) ions, respectively. Recovery results of HMs for the spiked samples were in the range of 92.8-101.0%, demonstrating the trueness of the method and its applicability to the water samples matrix.
AtıfScopus2WoS2OpenAlex1İncele
- MakaleYalnız künye2021Scopus SJRQ3Flame atomic absorption spectrometric determination of total chromium and cadmium in bean samples after ultrasonic-assisted microextraction using ionic liquid Aliquat-336
Elik, Adil; Karakoy, Tolga; Çilesiz, Yeter; Altunay, Nail
A new and rapid microextraction approach termed as ultrasonic-assisted ionic liquid-based microextraction (UA-ILME) was developed using ionic liquid Aliquat-336 as extraction solvent for the extraction of chromium and cadmium in bean samples collected from different regions in Turkey. The total amounts of analytes in the samples were measured by flame atomic absorption spectrophotometry. The basis of the extraction step is based on the complexation of Cr(III) and Cd(II) with diethyldithiocarbamate at pH 4.0. The hydrophobic ternary complexes containing analytes were then rapidly extracted from the sample solution to the ionic phase under the ultrasonic effect using tricaprylylmethylammonium chloride (Aliquat-336). Some experimental variables (pH, ligand amount, extraction solvent volume, ultrasound time, extraction temperature and sample volume) were optimized in detail. Following the optimization steps, the limits of detection (LODs, 3Sblank/m) for Cr(III) and Cd(II) were calculated as 0.45 ng mL−1 with linear range of 1.5–380 ng mL−1 and 0.25 ng mL−1 with linear range of 0.8–220 ng mL−1, respectively. Enrichment factors and average recoveries were ranged from 125.8–96.4 to 92.7–106.5%, respectively. The accuracy and precision of the method were validated by analyzing a certified reference material and spiked recovery tests. The UA-ILME method was successfully applied to the determination of Cd and Cr in the samples, highlighting that the matrix ions under consideration do not affect the extraction and determination steps.
AtıfScopus4OpenAlex6İncele
- MakaleAçık Erişim2015Scopus SJRQ2Simultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination
Duran, Celal; Ozdes, Duygu; Akcay, Hakki Turker; Serencam, Huseyin; Tufekci, Mehmet
ABSTRACT: In the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) benzene (BTEB), prior to their flame atomic absorption spectrometric (FAAS) detections. The experimental conditions were optimized in terms of pH of the aqueous solution, BTEB amount, standing time, centrifugation rate and time, and sample volume. Under the optimum experimental conditions, the detection limits for Cd(II), Co(II), and Ni(II) ions were found to be 0.13, 0.67, and 0.46 μg L−1, respectively, and the relative standard deviations for the analyte ions were found to be lower than 4.0%. The accuracy of the method was tested by analyzing certified reference material and spike tests. The method was applied to determine the levels of Cd(II), Co(II), and Ni(II) ions in sea and stream water, macaroni, red lentil, and cracked wheat samples.
AtıfScopus17WoS16OpenAlex16İncele
- MakaleYalnız künye2014Scopus SJRQ1Separation and preconcentration of lead, chromium and copper by using with the combination coprecipitation-flame atomic absorption spectrometric determination
Bahadır, Zekeriyya; Bulut, Volkan Numan; Ozdes, Duygu; Duran, Celal; Bektas, Hakan; Soylak, Mustafa
A coprecipitation method was developed for the quantitative separation and preconcentration of Pb(II), Cr(III) and Cu(II) ions. Analytes were coprecipitated using a triazole derivative (2-{4-[2-(1H-indol-3-yl)ethyl]-3-(4-chlorobenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}. N-aryl methylidene acetohydrazid). The analytes were analyzed by flame atomic absorption spectrometry. The parameters such as sample pH, amount of reagent, sample volume, matrix effects etc. were investigated. The enrichment factor for the analyzed metal ions was obtained as 50. The relative standard deviations (RSD) were in the range of 2.8-4.1%. The accuracy of the proposed procedure was checked by the analysis of the CRM-C-Sandy Soil C. The method was successfully applied to real samples.
AtıfScopus73WoS66OpenAlex65İncele
- MakaleYalnız künye2014Scopus SJRQ1Simultaneous separation and preconcentration of Ni(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples
Duran, Celal; Tumay, Sureyya O.; Ozdes, Duygu; Serencam, Huseyin; Bektas, Hakan
A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element-free coprecipitation of Ni(II) and Cu(II) ions by using 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-chlorobenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N′-(pyrrol-2-ylmethyliden)acetohydrazide (ICOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry. The detection limits for Ni(II) and Cu(II) ions were found to be 0.27 and 0.58 μg L-1, respectively, and the relative standard deviations for the analyte ions were lower than 4.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Ni(II) and Cu(II) ions levels in sea and stream water as liquid samples and red lentil and rice as solid samples.
AtıfScopus26WoS23OpenAlex25İncele
- MakaleAçık Erişim2013Scopus SJRQ3Solid phase extraction of Cd(ii) and pb(ii) ions by a new carbothioamide derivative
Ozdes, Duygu; Duran, Celal; Bayrak, Hacer; Serencam, Huseyin; Basri Senturk, Hasan
An effective, simple, low cost and accurate sorption-spectrophotometric platform for the extractions and subsequent quantifications of Cd(II) and Pb(II) ions in food and environmental samples has been described in this dissertation. The separation and preconcentration of the analyte ions were accomplished by solid phase extraction method based on the adsorption of their N-(4-methylphenyl)-2-{[(4-phenyl-5-pyridin-4-yl-4H-1,2,4-triazol-3-yl)thio] acetyl} hydrazinecarbothioamide (MFPTAHK) complex on Amberlite XAD-8 resin in a mini column. The developed method was systematically investigated in different set of experimental parameters that influence the separation and preconcentration of Cd(II) and Pb(II) ions. The precision of the method was determined by reproducibility studies and expressed as relative standard deviations (RSD %) which were less than 4% for both analyte ions. The limits of detections (LODs) for Cd(II) and Pb(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 0. 31 ?g L-1 and 0. 86 ?g L-1, respectively. The developed SPE procedure was utilized for the simultaneous extraction and determinations of Cd(II) and Pb(II) ions levels in rice, cracked wheat and red lentil as food samples and various water samples.
AtıfScopus5WoS4OpenAlex5İncele
- MakaleYalnız künye2013Scopus SJRQ3Application of carrier element free coprecipitation (CEFC) method for determination of Co(II), Cu(II) and Ni(II) ions in food and water samples
Serencam, Huseyin; Duran, Celal; Ozdes, Duygu; Bektas, Hakan
A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element free coprecipitation (CEFC) of Co(II), Cu(II), and Ni(II) ions by using 2-{4-[2-(1H-indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo- 4,5-dihydro-1H-1,2,4-triazol- 1-yl}-N'-(pyridin-2-yl methylidene)acetohydrazide (IMOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry (FAAS). The detection limits for Co(II), Cu(II) and Ni(II) ions were found to be 0.40, 0.16 and 0.17 μg L-1, respectively, and the relative standard deviations for the analyte ions were lower than 3.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Co(II), Cu(II) and Ni(II) ions levels in sea and stream water as liquid samples and red pepper, black pepper, and peppermint as solid samples.
AtıfScopus10WoS10İncele
- MakaleYalnız künye2013Scopus SJRQ2Separation and pre-concentration of palladium(II) from environmental and industrial samples by formation of a derivative of 1,2,4-triazole complex on Amberlite XAD-2010 resin
Serencam, Huseyin; Bulut, Volkan Numan; Tufekci, Mehmet; Gundogdu, Ali; Duran, Celal; Hamza, Sibel; Soylak, Mustafa
A simple separation/pre-concentration method was developed for extraction of Pd(II) in various environmental samples, based on its adsorption of 4-phenyl-5-{[(4-phenyl-5-pyridin-4-yl-4H-1,2,4-triazole-3-yl)thio]methyl}-4H-1,2,4-triazole-3-thyol (PPTTMET) complex on Amberlite XAD-2010 resin in a mini column. The ligand has high affinity for Pd(II) among many other metals that are taken into consideration. The flame atomic absorption spectrometry is employed to determine the concentration of Pd(II). The optimum working conditions which were determined are as follows: 0.05 mol L-1 HNO3 as working medium, 1.0 mol L-1 HCI in acetone as elution solvent, 0.75 mg of PPTTMET amount and 750 mL of sample volume. The system was independent from the flow rates between 3.1 and 23.1 mL min-1. The Pd(II) adsorption capacity of Amberlite XAD-2010 resin was found to be 12.8 mg g-1 and the enrichment factor was calculated as 375. The method was successfully applied for the determination of Pd(II) in motorway dust samples, anodic sludge, gold ore, industrial electronic waste materials and various water samples.
AtıfScopus17WoS15OpenAlex17İncele
- MakaleYalnız künye2013Scopus SJRQ2Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate
Tufekci, Mehmet; Bulut, Volkan Numan; Elvan, Hamide; Ozdes, Duygu; Soylak, Mustafa; Duran, Celal
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate- (Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1-2.2 μg L-1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.
AtıfScopus33WoS28OpenAlex30İncele
- MakaleYalnız künye2013Scopus SJRQ3Cadmium and nickel determinations in some food and water samples by the combination of carrier element-free coprecipitation and flame atomic absorption spectrometry
Bahadir, Zekeriyya; Ozdes, Duygu; Bulut, Volkan Numan; Duran, Celal; Elvan, Hamide; Bektas, Hakan; Soylak, Mustafa
A procedure for separation and enrichment of Cd(II) and Ni(II) ions based upon carrier element-free coprecipitation by using an organic coprecipitant, 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N-(3-fluoro-phenylmethyliden) acetohydrazide, prior to their flame atomic absorption spectrometric detections has been developed. The effects of varied experimental conditions on the performance of the developed method such as pH, sample volume, amount of coprecipitating agent, etc. were evaluated in detail on the recovery of analyte ions, and the influences of some anions and cations were investigated. The limits of detection for Cd(II) and Ni(II) ions based on three times the standard deviation of the blanks (N: 10) were obtained as 0.70 g L-1 and 1.21 g L-1, respectively. The accuracy of the method was tested by analyzing a certified reference material and by spike tests. The method was applied to determine the levels of cadmium and nickel in stream and sea water, rice, red lentil, and wheat samples.
AtıfScopus22WoS20OpenAlex21İncele
- BildiriYalnız künye2012Scopus SJRQ3Acetohydrazide derivative for selective separation and preconcentration of Cu(II) ions by coprecipitation method without using a carrier element
Ozdes, Duygu; Duran, Celal; Bektaş, Hakan; Tufekci, Mehmet; Soylak, Mustafa
A simple and rapid procedure based on the combination of carrier element free coprecipitation (CEFC) and flame atomic absorption spectrometric (FAAS) determinations has been developed for selective separation and preconcentration of Cu(II) ions in some environmental solid (Turkish and import coffee) and liquid (sea and stream waters) samples. In this method, acetohydrazide derivative was used as an organic coprecipitant without adding any carrier element for coprecipitation of Cu(II) ions. The preconcentration factor was found to be 50, the limit of detection (LOD) was 0.31 μgL -1, while the relative standard deviation (RSD) was found to be 1.6% for Cu(II) ions.
AtıfScopus15WoS15OpenAlex11İncele
- MakaleAçık Erişim2012Scopus SJRQ3Optimization of a new cloud point extraction procedure for the selective determination of trace amounts of total iron in some environmental samples
Duran, Celal; Özdeş, Duygu; Çelenk Kaya, Elif; Kantekin, Halit; Bulut, Volkan Numan; Tüfekçi, Mehmet
A new, simple, and rapid cloud point extraction (CPE) procedure system, combined with flame atomic absorption spectrometry (FAAS), was developed for selective separation, preconcentration, and determination of trace amounts of total iron in some environmental samples. The complexing agent, N,N-(2,2 - (ethane-1,2-diylbis(oxy))bis(ethane-2,1-diyl))bis(2-chloroacetamide) (EDBOCA), is selective at pH 5.0 for only Fe(II) and Fe(III) ions in the presence of Cu(II), Pb(II), Cd(II), Mn(II), Co(II), Cr(III), Cr(VI), Ni(II), Zn(II), Al(III), Mo(VI), Pd(II), Pt(IV), Au(III), and V(V) ions. The procedure is based on the complexation of Fe(III) ions with EDBOCA reagent in the presence of Triton X-114 (TX-114) as a non-ionic surfactant. The optimum conditions for the CPE of Fe(III) ions were investigated with respect to several experimental parameters such as pH of the solution, TX-114 and EDBOCA concentrations, incubation time and temperature, and centrifugation rate and time. The detection limit for Fe(III) ions based on the 3 times the standard deviation of the blanks (N:10) was found to be 1.22 μg L ?1 , while the relative standard deviation (RSD) was 4.2%. Environment Canada TM-25.3 and CRM-SA-C Sandy Soil C, as certified reference materials, were used, and spike tests were applied to validate the method. The method was applied to some real environmental samples to evaluate their total iron levels.
AtıfScopus22WoS18OpenAlex13TR Dizin1
İncele - MakaleYalnız künye2011Scopus SJRQ2Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples
Duran, Celal; Ozdes, Duygu; Sahin, Deniz; Bulut, Volkan Numan; Gundogdu, Ali; Soylak, Mustafa
A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions, cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45μgL-1, respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples.
AtıfScopus56WoS54OpenAlex47İncele