A green and simplified approach for the quantitative and sensitive analysis of heavy metal ions in sea and stream waters
Özet
Elimination of the matrix effect is a major challenge in developing a method for the quantification of heavy metals (HMs) in water samples. In this regard, the current research describes the simultaneous analyses of Cu(II), Cd(II), and Ni(II) ions in water matrices through flame atomic absorption spectrophotometry (FAAS) after preconcentration with carrier element-free co-precipitation (CEFC) technique by the help of an organic co-precipitant, 3-{[5-(4-Chlorobenzyl)-3-(4-chlorophenyl)-1H-1,2,4-triazol-1-yl]-methyl}-4-[2,4-(dichlorobenzylidene)amino]-1H-1,2,4- triazole-5(4H)-thione (CCMBATT). Based on our literature research, CCMBATT was employed for the first time in this study as an organic co-precipitant for the preconcentration of HMs. Factors such as solution pH, concentration of co-precipitant, sample volume, standing time, centrifugation rate, and time were thoroughly examined and optimized to achieve the highest efficiency in terms of HM recovery. The limits of detection (LODs) (with 10 number of tests) of 0.54, 0.34, and 1.95 μg L-1 and the relative standard deviations (RSD %) of 2.1, 3.3, and 3.0 were determined for Cu(II), Cd(II) and Ni(II) ions, respectively. Recovery results of HMs for the spiked samples were in the range of 92.8-101.0%, demonstrating the trueness of the method and its applicability to the water samples matrix.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Duran, Celal | |
| dc.contributor.author | Camoglu, Aslihan Yilmaz | |
| dc.contributor.author | Ozdes, Duygu | |
| dc.contributor.author | Bekircan, Olcay | |
| dc.date.accessioned | 2026-10-22T10:19:31.450856644Z | |
| dc.date.available | 2026-10-22T10:19:31.450856644Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | Elimination of the matrix effect is a major challenge in developing a method for the quantification of heavy metals (HMs) in water samples. In this regard, the current research describes the simultaneous analyses of Cu(II), Cd(II), and Ni(II) ions in water matrices through flame atomic absorption spectrophotometry (FAAS) after preconcentration with carrier element-free co-precipitation (CEFC) technique by the help of an organic co-precipitant, 3-{[5-(4-Chlorobenzyl)-3-(4-chlorophenyl)-1H-1,2,4-triazol-1-yl]-methyl}-4-[2,4-(dichlorobenzylidene)amino]-1H-1,2,4- triazole-5(4H)-thione (CCMBATT). Based on our literature research, CCMBATT was employed for the first time in this study as an organic co-precipitant for the preconcentration of HMs. Factors such as solution pH, concentration of co-precipitant, sample volume, standing time, centrifugation rate, and time were thoroughly examined and optimized to achieve the highest efficiency in terms of HM recovery. The limits of detection (LODs) (with 10 number of tests) of 0.54, 0.34, and 1.95 μg L-1 and the relative standard deviations (RSD %) of 2.1, 3.3, and 3.0 were determined for Cu(II), Cd(II) and Ni(II) ions, respectively. Recovery results of HMs for the spiked samples were in the range of 92.8-101.0%, demonstrating the trueness of the method and its applicability to the water samples matrix. | |
| dc.description.sponsorship | Karadeniz Teknik Üniversitesi, KTU | |
| dc.identifier.doi | 10.2166/wst.2023.371 | |
| dc.identifier.eissn | 1996-9732 | |
| dc.identifier.endpage | 2872 | |
| dc.identifier.issn | 0273-1223 | |
| dc.identifier.issue | 11 | |
| dc.identifier.pmid | 38096074 | |
| dc.identifier.scopus | 2-s2.0-85179771795 | |
| dc.identifier.startpage | 2862 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/11947 | |
| dc.identifier.volume | 88 | |
| dc.identifier.wos | WOS:001105270000001 | |
| dc.language.iso | en | |
| dc.publisher | IWA Publishing | |
| dc.relation.ispartof | Water Science and Technology | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | cadmium | |
| dc.subject | co-precipitation | |
| dc.subject | copper | |
| dc.subject | flame atomic absorption spectrometry | |
| dc.subject | nickel | |
| dc.subject | preconcentration | |
| dc.subject.classification | Engineering, Environmental | |
| dc.subject.classification | Environmental Sciences | |
| dc.subject.classification | Water Resources | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Environmental Sciences & Ecology | |
| dc.subject.other | Cadmium | |
| dc.subject.other | Hydrogen-Ion Concentration | |
| dc.subject.other | Ions | |
| dc.subject.other | Limit of Detection | |
| dc.subject.other | Metals, Heavy | |
| dc.subject.other | Rivers | |
| dc.subject.other | Spectrophotometry, Atomic | |
| dc.subject.other | Water | |
| dc.subject.other | Water Pollutants, Chemical | |
| dc.subject.other | Absorption spectroscopy | |
| dc.subject.other | Atomic absorption spectrometry | |
| dc.subject.other | Cadmium compounds | |
| dc.subject.other | Copper compounds | |
| dc.subject.other | Heavy metals | |
| dc.subject.other | Metal ions | |
| dc.subject.other | Nickel compounds | |
| dc.subject.other | Water absorption | |
| dc.subject.other | cupric ion | |
| dc.subject.other | heavy metal | |
| dc.subject.other | metal ion | |
| dc.subject.other | sea water | |
| dc.subject.other | ion | |
| dc.subject.other | Co precipitants | |
| dc.subject.other | Co-precipitation | |
| dc.subject.other | Flame atomic absorption spectrometry | |
| dc.subject.other | Heavy metal ion | |
| dc.subject.other | Organics | |
| dc.subject.other | Pre-concentration | |
| dc.subject.other | Sensitive analysis | |
| dc.subject.other | Stream water | |
| dc.subject.other | Water samples | |
| dc.subject.other | atomic absorption spectroscopy | |
| dc.subject.other | concentration (composition) | |
| dc.subject.other | copper | |
| dc.subject.other | nickel | |
| dc.subject.other | precipitation (chemistry) | |
| dc.subject.other | seawater | |
| dc.subject.other | streamwater | |
| dc.subject.other | Article | |
| dc.subject.other | centrifugation | |
| dc.subject.other | chemical structure | |
| dc.subject.other | clinical evaluation | |
| dc.subject.other | clinical examination | |
| dc.subject.other | controlled study | |
| dc.subject.other | green chemistry | |
| dc.subject.other | nonhuman | |
| dc.subject.other | pH | |
| dc.subject.other | precipitation | |
| dc.subject.other | process optimization | |
| dc.subject.other | quantitative analysis | |
| dc.subject.other | sensitivity analysis | |
| dc.subject.other | solid phase extraction | |
| dc.subject.other | standard | |
| dc.subject.other | stream (river) | |
| dc.subject.other | time | |
| dc.subject.other | water analysis | |
| dc.subject.other | water sampling | |
| dc.subject.other | atomic spectrometry | |
| dc.subject.other | procedures | |
| dc.subject.other | river | |
| dc.subject.other | water pollutant | |
| dc.subject.other | Coprecipitation | |
| dc.title | A green and simplified approach for the quantitative and sensitive analysis of heavy metal ions in sea and stream waters | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 1 | |
| rdl.citation.scopus | 2 | |
| rdl.citation.wos | 2 | |
| rdl.department | Gumushane Vocational School, Gumushane University, Gumushane, Turkey | |
| rdl.oa.status | gold | |
| rdl.oa.url | https://iwaponline.com/wst/article-pdf/doi/10.2166/wst.2023.371/1324583/wst2023371.pdf | |
| rdl.sdg | SDG06 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |