Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate
Özet
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate- (Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1-2.2 μg L-1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Tufekci, Mehmet | |
| dc.contributor.author | Bulut, Volkan Numan | |
| dc.contributor.author | Elvan, Hamide | |
| dc.contributor.author | Ozdes, Duygu | |
| dc.contributor.author | Soylak, Mustafa | |
| dc.contributor.author | Duran, Celal | |
| dc.date.accessioned | 2026-10-22T10:20:58.489120762Z | |
| dc.date.available | 2026-10-22T10:20:58.489120762Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate- (Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1-2.2 μg L-1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions. | |
| dc.identifier.doi | 10.1007/s10661-012-2618-9 | |
| dc.identifier.endpage | 1115 | |
| dc.identifier.issn | 1573-2959 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 22527456 | |
| dc.identifier.scopus | 2-s2.0-84874431433 | |
| dc.identifier.startpage | 1107 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/13140 | |
| dc.identifier.volume | 185 | |
| dc.identifier.wos | WOS:000313359000007 | |
| dc.language.iso | en | |
| dc.publisher | SPRINGER | |
| dc.relation.ispartof | Environmental Monitoring and Assessment | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Coprecipitation | |
| dc.subject | Diethyldithiocarbamate | |
| dc.subject | Flame atomic absorption spectrometry | |
| dc.subject | Heavy metal | |
| dc.subject | Preconcentration | |
| dc.subject.classification | Environmental Sciences | |
| dc.subject.classification | Environmental Sciences & Ecology | |
| dc.subject.other | Cadmium | |
| dc.subject.other | Chemical Precipitation | |
| dc.subject.other | Cobalt | |
| dc.subject.other | Ditiocarb | |
| dc.subject.other | Environmental Monitoring | |
| dc.subject.other | Environmental Pollutants | |
| dc.subject.other | Food Analysis | |
| dc.subject.other | Food Contamination | |
| dc.subject.other | Fresh Water | |
| dc.subject.other | Ions | |
| dc.subject.other | Lead | |
| dc.subject.other | Metals | |
| dc.subject.other | Molybdenum | |
| dc.subject.other | Seawater | |
| dc.subject.other | Spectrophotometry, Atomic | |
| dc.subject.other | Zinc | |
| dc.subject.other | Solanum melongena | |
| dc.subject.other | Atomic absorption spectrometry | |
| dc.subject.other | Centrifugation | |
| dc.subject.other | Coprecipitation | |
| dc.subject.other | Heavy metals | |
| dc.subject.other | Zinc compounds | |
| dc.subject.other | diethyldithiocarbamic acid | |
| dc.subject.other | drinking water | |
| dc.subject.other | heavy metal | |
| dc.subject.other | sea water | |
| dc.subject.other | ion | |
| dc.subject.other | metal | |
| dc.subject.other | Certified reference materials | |
| dc.subject.other | Diethyldithiocarbamate | |
| dc.subject.other | Experimental conditions | |
| dc.subject.other | Flame atomic absorption spectrometric determination | |
| dc.subject.other | Flame atomic absorption spectrometry | |
| dc.subject.other | Pre-concentration | |
| dc.subject.other | Pre-concentration procedures | |
| dc.subject.other | Relative standard deviations | |
| dc.subject.other | aqueous solution | |
| dc.subject.other | atomic absorption spectroscopy | |
| dc.subject.other | carbamate (ester) | |
| dc.subject.other | concentration (composition) | |
| dc.subject.other | experimental study | |
| dc.subject.other | ionic composition | |
| dc.subject.other | precipitation (chemistry) | |
| dc.subject.other | streamwater | |
| dc.subject.other | MLCS | |
| dc.subject.other | MLOWN | |
| dc.subject.other | accuracy | |
| dc.subject.other | analytical parameters | |
| dc.subject.other | article | |
| dc.subject.other | aubergine | |
| dc.subject.other | baby food | |
| dc.subject.other | centrifugation rate | |
| dc.subject.other | centrifugation time | |
| dc.subject.other | chemical analysis | |
| dc.subject.other | concentration (parameters) | |
| dc.subject.other | controlled study | |
| dc.subject.other | limit of detection | |
| dc.subject.other | pH | |
| dc.subject.other | preconcentration factor | |
| dc.subject.other | process development | |
| dc.subject.other | quantitative analysis | |
| dc.subject.other | sample volume | |
| dc.subject.other | separation technique | |
| dc.subject.other | standing rate | |
| dc.subject.other | stream (river) | |
| dc.subject.other | water analysis | |
| dc.subject.other | chemistry | |
| dc.subject.other | methodology | |
| dc.subject.other | pollutant | |
| dc.subject.other | precipitation | |
| dc.subject.other | Cadmium compounds | |
| dc.title | Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 30 | |
| rdl.citation.scopus | 33 | |
| rdl.citation.wos | 28 | |
| rdl.oa.status | closed | |
| rdl.sdg | SDG06 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |