Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleAçık Erişim2013Separation and preconcentration of copper in environmental samples on amberlite XAD-8 resin after complexation with a carbothioamide derivative
Elvan, Hamide; Ozdes, Duygu; Duran, Celal; Sahin, Deniz; Tufekci, Mehmet; Bahadir, Zekeriyya
A new solid phase extraction (SPE) method has been developed for the selective separation and preconcentration of Cu (II) ions in food and water samples prior to its flame atomic absorption spectrometry determination. The method is based on the adsorption of the Cu(II)-2-{[4-Amino-3-(4-methylphenyl-5- oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl]acetyl}-N-phenyl hydrazinecarbothioamide complex on Amberlite XAD-8 resin. The metal complex retained on the resin was eluted with 7.5 mL of 2.0 mol L-1 HCl in acetone. The optimum conditions for the SPE of Cu(II) ions were investigated, and the method was subsequently applied to sea water, stream water, rice, tea, and tobacco samples for the determination of Cu(II) levels.
- MakaleAçık Erişim2013Development of a new solid phase extraction procedure for selective separation and enrichment of Au(III) ions in environmental samples
Elvan, Hamide; Ozdes, Duygu; Duran, Celal; Bulut, V. Numan; Gümrükçüoglu, Nurhan; Soylak, Mustafa
A highly sensitive, selective and low cost solid phase extraction (SPE) procedure was developed for separation and enrichment of Au(III) ions in environmental samples prior to its flame atomic absorption spectrometric detection. Au(III)-2-pyridin-5-(4-tolyl)-1,3,4-oxadiazole (PYTOX) complex was adsorbed quantitatively on Amberlite XAD-4 resin in 0.5 mol L-1 HNO3 condition and the elution was carried out with 7.5 mL of 1.0 mol L-1 HCl in acetone. Some analytical parameters, affect the recoveries of Au(III) ions, such as HNO3 concentration of sample solution, amount of PYTOX, type, concentration and volume of eluent, sample volume and concomitants were examined. Adopting optimized experimental conditions, the limit of detection for Au(III) ions was 1.03 μg L-1 with preconcentration factor of 50 and a relative standard deviation (RSD) of 3.7%. The determination of Au(III) ions in anodic slime, gold ore, soil and sea and stream waters was performed after checking the accuracy of the method by addition-recovery tests.
- MakaleYalnız künye2013Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate
Tufekci, Mehmet; Bulut, Volkan Numan; Elvan, Hamide; Ozdes, Duygu; Soylak, Mustafa; Duran, Celal
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)-diethyldithiocarbamate- (Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1-2.2 μg L-1 while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.
- MakaleYalnız künye2013Cadmium and nickel determinations in some food and water samples by the combination of carrier element-free coprecipitation and flame atomic absorption spectrometry
Bahadir, Zekeriyya; Ozdes, Duygu; Bulut, Volkan Numan; Duran, Celal; Elvan, Hamide; Bektas, Hakan; Soylak, Mustafa
A procedure for separation and enrichment of Cd(II) and Ni(II) ions based upon carrier element-free coprecipitation by using an organic coprecipitant, 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N-(3-fluoro-phenylmethyliden) acetohydrazide, prior to their flame atomic absorption spectrometric detections has been developed. The effects of varied experimental conditions on the performance of the developed method such as pH, sample volume, amount of coprecipitating agent, etc. were evaluated in detail on the recovery of analyte ions, and the influences of some anions and cations were investigated. The limits of detection for Cd(II) and Ni(II) ions based on three times the standard deviation of the blanks (N: 10) were obtained as 0.70 g L-1 and 1.21 g L-1, respectively. The accuracy of the method was tested by analyzing a certified reference material and by spike tests. The method was applied to determine the levels of cadmium and nickel in stream and sea water, rice, red lentil, and wheat samples.

