Simultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination

MakaleAçık Erişim
  • SDG 6 · Temiz Su ve Sanitasyon

Özet

ABSTRACT: In the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) benzene (BTEB), prior to their flame atomic absorption spectrometric (FAAS) detections. The experimental conditions were optimized in terms of pH of the aqueous solution, BTEB amount, standing time, centrifugation rate and time, and sample volume. Under the optimum experimental conditions, the detection limits for Cd(II), Co(II), and Ni(II) ions were found to be 0.13, 0.67, and 0.46 μg L−1, respectively, and the relative standard deviations for the analyte ions were found to be lower than 4.0%. The accuracy of the method was tested by analyzing certified reference material and spike tests. The method was applied to determine the levels of Cd(II), Co(II), and Ni(II) ions in sea and stream water, macaroni, red lentil, and cracked wheat samples.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12043Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDuran, Celal
dc.contributor.authorOzdes, Duygu
dc.contributor.authorAkcay, Hakki Turker
dc.contributor.authorSerencam, Huseyin
dc.contributor.authorTufekci, Mehmet
dc.date.accessioned2026-10-22T10:19:37.490976681Z
dc.date.available2026-10-22T10:19:37.490976681Z
dc.date.issued2015
dc.description.abstractABSTRACT: In the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) benzene (BTEB), prior to their flame atomic absorption spectrometric (FAAS) detections. The experimental conditions were optimized in terms of pH of the aqueous solution, BTEB amount, standing time, centrifugation rate and time, and sample volume. Under the optimum experimental conditions, the detection limits for Cd(II), Co(II), and Ni(II) ions were found to be 0.13, 0.67, and 0.46 μg L−1, respectively, and the relative standard deviations for the analyte ions were found to be lower than 4.0%. The accuracy of the method was tested by analyzing certified reference material and spike tests. The method was applied to determine the levels of Cd(II), Co(II), and Ni(II) ions in sea and stream water, macaroni, red lentil, and cracked wheat samples.
dc.identifier.doi10.1080/19443994.2013.839401
dc.identifier.eissn1944-3986
dc.identifier.endpage397
dc.identifier.issn1944-3994
dc.identifier.issue2
dc.identifier.scopus2-s2.0-84921026007
dc.identifier.startpage390
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12043
dc.identifier.volume53
dc.identifier.wosWOS:000347687800013
dc.language.isoen
dc.publisherTaylor and Francis Inc.
dc.relation.ispartofDesalination and Water Treatment
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCarrier element free coprecipitation
dc.subjectFlame atomic absorption spectrometry
dc.subjectHeavy metals
dc.subjectPreconcentration
dc.subjectSeparation
dc.subject.classificationEngineering, Chemical
dc.subject.classificationWater Resources
dc.subject.classificationEngineering
dc.subject.otherLens culinaris
dc.subject.otherTriticum aestivum
dc.titleSimultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex16
rdl.citation.scopus17
rdl.citation.wos16
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.1080/19443994.2013.839401
rdl.sdgSDG06
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)