Sürdürülebilir Kalkınma Amaçları

  • MakaleAçık Erişim2015
    Selective separation, preconcentration and determination of Pd(II) ions in environmental samples by coprecipitation with a 1,2,4-triazole derivative

    Ozdes, Duygu; Duran, Celal; Serencam, Huseyin; Sahin, Deniz; Gundogdu, Ali; Soylak, Mustafa

    A simple, sensitive, facile and low cost methodology, combined with flame atomic absorption spectrometry (FAAS), was employed to evaluate the selective separation and preconcentration of Pd(II) ions in environmental samples by using a triazole derivative as an organic coprecipitating agent without a carrier element. The developed method was systematically investigated in different set of experimental parameters that influence the quantitative recovery of Pd(II) ions. The accuracy of the method was tested by analyzing certified reference material and spike tests. The developed coprecipitation procedure has been applied to road dust, anodic slime, industrial electronic waste materials and water samples to determine their Pd(II) levels.

  • MakaleAçık Erişim2013
    Separation and preconcentration of copper in environmental samples on amberlite XAD-8 resin after complexation with a carbothioamide derivative

    Elvan, Hamide; Ozdes, Duygu; Duran, Celal; Sahin, Deniz; Tufekci, Mehmet; Bahadir, Zekeriyya

    A new solid phase extraction (SPE) method has been developed for the selective separation and preconcentration of Cu (II) ions in food and water samples prior to its flame atomic absorption spectrometry determination. The method is based on the adsorption of the Cu(II)-2-{[4-Amino-3-(4-methylphenyl-5- oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl]acetyl}-N-phenyl hydrazinecarbothioamide complex on Amberlite XAD-8 resin. The metal complex retained on the resin was eluted with 7.5 mL of 2.0 mol L-1 HCl in acetone. The optimum conditions for the SPE of Cu(II) ions were investigated, and the method was subsequently applied to sea water, stream water, rice, tea, and tobacco samples for the determination of Cu(II) levels.

    • SDG 6 · Temiz Su ve Sanitasyon
  • MakaleYalnız künye2011
    Preconcentration of Cd(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples

    Duran, Celal; Ozdes, Duygu; Sahin, Deniz; Bulut, Volkan Numan; Gundogdu, Ali; Soylak, Mustafa

    A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions, cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45μgL-1, respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples.

    • SDG 6 · Temiz Su ve Sanitasyon