    System identification of arch dam model strengthened with CFRP composite materials

    Altunisik, A.C.; Gunaydin, M.; Sevim, B.; Adanur, S.

    This paper presents the structural identification of an arch dam model for the damaged, repaired and strengthened conditions under different water levels. For this aim, an arch dam-reservoir-foundation model has been constructed. Ambient vibration tests have been performed on the damaged, repaired and strengthened dam models for the empty reservoir (0 cm), 10 cm, 20 cm, 30 cm, 40 cm, 50 cm and full reservoir (60 cm) water levels to illustrate the effects of water levels on the dynamics characteristics. Enhanced Frequency Domain Decomposition Method in the frequency domain has been used to extract the dynamic characteristics. The dynamic characteristics obtained from the damaged, repaired and strengthened dam models show that the natural frequencies and damping ratios are considerably affected from the varying water level. The maximum differences between the frequencies for the empty and full reservoir are obtained as 16%, 33%, and 25% for damaged, repaired and strengthened model respectively. Mode shapes obtained from the all models are not affected by the increasing water level. Also, after the repairing and strengthening implementations, the natural frequencies of the arch dam model increase significantly. After strengthening, between 46-92% and 43-62% recovery in the frequencies are calculated for empty and full reservoir respectively. Apparently, after strengthening implementation, the mode shapes obtained are more acceptable and distinctive compared to those for the damaged model.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus11WoS10OpenAlex4
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2015Scopus SJRQ3
    Time dependent changing of dynamic characteristics of laboratory arch dam model

    Altunişik, Ahmet Can; Sevİm, Barış; Bayraktar, Alemdar; Adanur, Süleyman; Günaydin, Murat

    This paper investigates the time dependent changing of dynamic characteristics of laboratory arch dam models using ambient vibration test. For this aim, a prototype arch dam-reservoir-foundation model is constructed in laboratory conditions. The first experimental measurement tests are performed after the poured concrete aged for 10 months for some damage scenarios such as undamaged, minor-damaged and severely damaged of dam body in November 2009. To extract the experimental dynamic characteristics such as natural frequencies, mode shapes and damping ratios, a small impact effect is used as a source of ambient vibrations. Experimental measurements tests are repeated using same excitations considering severely damaged conditions with and without reservoir water in February 2014, and the dynamic characteristics are obtained, experimentally. Enhanced Frequency Domain Decomposition Method in the frequency domain is used to extract the experimental dynamic characteristics. At the end of the study, experimentally identified dynamic characteristics are compared with each other and time effects are investigated in detail. Maximum differences between the natural frequencies obtained as 15.36% and 14.38% in the third mode for empty and full reservoir conditions, respectively. It is thought that the increase of the natural frequencies is resulted from gaining of rigidity of the concrete, ageing, temperature and different environmental effects.

    AtıfScopus6WoS5OpenAlex7
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2015Scopus SJRQ1
    CFRP composite retrofitting effect on the dynamic characteristics of arch dams

    Altunişik, Ahmet Can; Günaydin, Murat; Sevim, Bariş; Bayraktar, Alemdar; Adanur, Süleyman

    The purpose of this study is to investigate the effect of retrofitting dynamic characteristics of a damaged laboratory arch dam model, subsequently repaired with high-strength structural mortar and strengthened with composite carbon fiber reinforced polymer. This study constructed in laboratory conditions is a prototype arch dam-reservoir-foundation model. Five test cases of ambient vibration on the arch dam model illustrate the changes in dynamic characteristics: natural frequency, mode shape, and damping ratio, before and after retrofitting. The ambient vibration tests collected data from the dam body during vibrations by natural excitations which provided small impacts and response signals from sensitivity accelerometers placed at crest points. Enhanced Frequency Domain Decomposition Method in the frequency domain extracts the experimental dynamic characteristics. At the end of the study, experimentally identified dynamic characteristics obtained from all test cases have been compared with each other. Apparently, after the retrofitting, the natural frequencies of the dam body increased considerably, demonstrating that the retrofitting, including repairing and strengthening is very effective on the flashback of initial dynamic characteristics.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus26WoS23OpenAlex21
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2011Scopus SJRQ1
    Dynamic Characteristics of a Prototype Arch Dam

    Sevim, B.; Bayraktar, A.; Altunışık, A.C.; Adanur, S.; Akköse, M.

    This study determines the dynamic characteristics of a prototype arch dam-reservoir-foundation system using Operational Modal Analysis method. Achievement of this purpose involved construction of a prototype arch dam-reservoir-foundation system under laboratory conditions. Ambient vibration tests on the arch dam model identified its natural frequencies, mode shapes, and damping ratios. Natural excitations such as small impact loads vibrated to arch dam. Sensitivity accelerometers which were placed on the dam's crest collected signals in measurements. Measurements were recorded for empty and full reservoirs. Operational Modal Analysis software processed signals which were collected from the ambient vibration tests. Enhanced Frequency Domain Decomposition technique estimated dynamic characteristics of the dam. Results showed that there was an approximate 20-25% difference between natural frequencies related to empty and full reservoirs.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus9WoS9OpenAlex8
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2011Scopus SJRQ1
    Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

    Sevim, Bariş; Bayraktar, Alemdar; Can Altunişik, Ahmet

    This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir- foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.