Investigation of In-Vitro Properties of NiTi Alloy After Micro Arc Oxidation

BildiriAçık Erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

As material science is integrated into medical science as in other fields, the variety, development and usage areas of biomaterials increase. One of the biomaterials in this variety is NiTi alloys. This study was focused on the coating of TiO2 layer by using the method of Micro Ark Oxidation with the aim of the improvement of surface and mechanical properties of Shapedmemory and bio material NiTi alloy. Structural properties of the coatings were analysed by of SEM and XRD. In vitro ability was investigated by soaking the coated NiTi samples in simulated body fluid (SBF) at temperature 37 degrees C for various time periods. After soaking, Ni+2 release was applied to the media where coated and uncoated shape-memory NiTi samples are available, and its control was made by means of ICP-MS device. The results also show that Toxic and carcinogenic effects of Ni+2 release is significantly reduced by the TiO2 coating. Thus, it is observed that the properties that limit the use of NiTi alloys has been substantially fixed by MAO coating. It was found that the bioactive properties of the TiO2 coated NiTi substrate increased by MAO method and at the end of the 72 hour, there was no statistically any cytotoxicity in cell viability compared to the NiTi substrate.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/16242Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.2339/politeknik.682062Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
3
OpenAlex
2
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSüküroglu, Suleyman
dc.contributor.authorTotik, Yapr
dc.contributor.authorSüküroglu, Ebru Emine
dc.contributor.authorKüçükosman, Ridvan
dc.date.accessioned2026-10-22T10:29:07.466578334Z
dc.date.available2026-10-22T10:29:07.466578334Z
dc.date.issued2021-06
dc.description.abstractAs material science is integrated into medical science as in other fields, the variety, development and usage areas of biomaterials increase. One of the biomaterials in this variety is NiTi alloys. This study was focused on the coating of TiO2 layer by using the method of Micro Ark Oxidation with the aim of the improvement of surface and mechanical properties of Shapedmemory and bio material NiTi alloy. Structural properties of the coatings were analysed by of SEM and XRD. In vitro ability was investigated by soaking the coated NiTi samples in simulated body fluid (SBF) at temperature 37 degrees C for various time periods. After soaking, Ni+2 release was applied to the media where coated and uncoated shape-memory NiTi samples are available, and its control was made by means of ICP-MS device. The results also show that Toxic and carcinogenic effects of Ni+2 release is significantly reduced by the TiO2 coating. Thus, it is observed that the properties that limit the use of NiTi alloys has been substantially fixed by MAO coating. It was found that the bioactive properties of the TiO2 coated NiTi substrate increased by MAO method and at the end of the 72 hour, there was no statistically any cytotoxicity in cell viability compared to the NiTi substrate.
dc.identifier.doi10.2339/politeknik.682062
dc.identifier.eissn2147-9429
dc.identifier.endpage382
dc.identifier.issn1302-0900
dc.identifier.issue2
dc.identifier.startpage373
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/16242
dc.identifier.volume24
dc.identifier.wosWOS:000661468600003
dc.language.isotr
dc.publisherGAZI UNIV
dc.relation.conference3rd International Conference on Advanced Engineering Technologies (ICADET)
dc.relation.ispartofJOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectNiTi
dc.subjectMAO
dc.subjectin-vitro test
dc.subjectMTT test
dc.subjectin-vitro cytotoxicity
dc.subjectNi+2 release
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationEngineering
dc.subject.otherPLASMA ELECTROLYTIC OXIDATION
dc.subject.otherCORROSION-RESISTANCE
dc.subject.otherPOROUS TITANIUM
dc.subject.otherSURFACE
dc.subject.otherMICROSTRUCTURE
dc.subject.otherCOATINGS
dc.subject.otherSCAFFOLDS
dc.subject.otherALUMINUM
dc.subject.otherGROWTH
dc.titleInvestigation of In-Vitro Properties of NiTi Alloy After Micro Arc Oxidation
dc.typeConference Object
rdl.citation.openalex2
rdl.citation.trdizin0
rdl.citation.wos3
rdl.conference.dateSEP 19-21, 2019
rdl.conference.placeBayburt Univ, Bayburt, TURKEY
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/tr/download/article-file/1034708
rdl.sdgSDG03
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.wos.indexEmerging Sources Citation Index (ESCI)