Comparisons of different Maximum Power Point Tracking Strategies with Zeta Converter

MakaleYalnız künye

Özet

Maximum power point tracking (MPPT) strategy is one of the major parameters affecting efficiency in photovoltaic (PV) systems. In this paper, distributed MPPT approaches are compared with central mode MPPT. Advantages and disadvantages of submodule level MPPT technique and module level MPPT approach are shown with simulation studies. Comparisons are made with incremental conductance (IC) algorithm. In this context, non-isolated zeta converter is used as a power-processing unit. Effect of the MPPT strategy on the collected energy performance is observed by simulation studies performed in MATLAB/Simulink. It is clear by these studies that energy capture is bigger in submodule level MPPT strategy and module level MPPT with respect to central mode which is seen by simulations. However, central mode MPPT offers cost effective solution because of the low hardware requirements.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/17484Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBasoglu, Mustafa Engin
dc.date.accessioned2026-10-22T10:38:56.933232431Z
dc.date.available2026-10-22T10:38:56.933232431Z
dc.date.issued2021
dc.description.abstractMaximum power point tracking (MPPT) strategy is one of the major parameters affecting efficiency in photovoltaic (PV) systems. In this paper, distributed MPPT approaches are compared with central mode MPPT. Advantages and disadvantages of submodule level MPPT technique and module level MPPT approach are shown with simulation studies. Comparisons are made with incremental conductance (IC) algorithm. In this context, non-isolated zeta converter is used as a power-processing unit. Effect of the MPPT strategy on the collected energy performance is observed by simulation studies performed in MATLAB/Simulink. It is clear by these studies that energy capture is bigger in submodule level MPPT strategy and module level MPPT with respect to central mode which is seen by simulations. However, central mode MPPT offers cost effective solution because of the low hardware requirements.
dc.identifier.eissn2147-284X
dc.identifier.endpage228
dc.identifier.issue3
dc.identifier.startpage221
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/17484
dc.identifier.volume9
dc.language.isoen
dc.relation.ispartofBalkan Journal of Electrical and Computer Engineering
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectMühendislik, Elektrik ve Elektronik
dc.subjectEnerji ve Yakıtlar
dc.titleComparisons of different Maximum Power Point Tracking Strategies with Zeta Converter