Yazarlar
Yayınlar
- MakaleYalnız künye2025Synthesis of New Triazole Compounds: Determination of Antiurease and Antioxidant Activities
Gümrükçüoğlu, T.İ.; Akgün, H.; Sökmen, B. Bilgin; Bektaş, H.
Abstract: Objective: In this study, we synthesized five novel triazole derivatives and biologically evaluated their antiurease and antioxidant properties. Methods: Five novel 1,2,4-triazole derivatives (5a–5e) were synthesized and tested for their urease inhibition and antioxidant activities using spectrophotometric methods. Results and Discussion: All compounds exhibited varying degrees of biological activity, with compound 5c demonstrating the most potent urease inhibition and radical scavenging capacity. Statistical analysis confirmed significant differences among the compounds, particularly highlighting the superior performance of 5c. Conclusions: These results suggest that halogen-substituted triazoles are promising candidates for further pharmacological development aimed at oxidative stress-related conditions and urease-associated pathologies.
- MakaleYalnız künye2016A novel carrier element-free co-precipitation method for separation/preconcentration of lead and cadmium ions from environmental matrices
Bulut, Volkan Numan; Demirci, Hamit; Ozdes, Duygu; Gundogdu, Ali; Bekircan, Olcay; Soylak, Mustafa; Duran, Celal
A new separation and pre-concentration method was presented in this study for two trace heavy metal ions, lead (Pb2+) and cadmium (Cd2+) from aqueous solutions, based on a carrier element free co-precipitation (CEFC) method using a triazole derivate, 3-(4-tert-butylphenyl)−5-phenyl-4-(2-hydroxy-5-methoxybenzylamino)−4H-1,2,4-triazole as an organic co-precipitating agent. The method was optimized with some analytical parameters which affect the quantitative recoveries of study metals. According to the results, optimum pH of solution, quantity of co-precipitating agent, centrifugation and incubation time, and sample volume were determined as 6.0, 1.5 mg, 10 min, and 10 min, and 100 mL, respectively. In addition, no significant matrix interferences were observed over the recovery of the metal ions. For analytical figure of merit, RSD values of the method were found as 5.7 and 4.8 for Pb2+ and Cd2+, respectively. LOD values were also calculated as 2.0 µg L−1 for Pb2+ and 0.2 µg L−1 for Cd2+. The accuracy of method was checked with spiked/recovery tests and analysis of a standard reference material. The developed method was finally applied to the real liquid/solid samples under the optimum conditions.
