    Monte Carlo calculation of geometry-dependent true coincidence summing correction factors for the gamma-rays of 214Bi in HPGe detectors

    Çelik, Necati

    True coincidence summing (TCS) effects in gamma-ray spectrometry introduce significant systematic uncertainties in activity determinations, particularly for radionuclides with complex decay schemes such as 214Bi. This study presents a comprehensive Monte Carlo investigation of TCS correction factors (CFs) for seven major gamma-ray lines of 214Bi. The primary contribution of this study is the systematic decoupling of detector geometry effects: nine distinct HPGe detector configurations were simulated with varying crystal dimensions, dead layers, and hole geometries, followed by an isolated analysis of crystal radius versus crystal length contributions for both point and extended source geometries. The decay scheme of 214Bi was meticulously modeled using Nucleide 2000 data, incorporating all beta branches, gamma transitions, internal conversion coefficients, and cascade probabilities to ensure high-fidelity representation of the decay scheme. Results demonstrate that crystal radius exerts a substantially stronger influence on TCS CFs than crystal length, with point source values at 609.3 keV increasing by 18.2% across the radius range of 2.1–4.5 cm, compared to only 3.7% variation across the length range of 3–11 cm. Extended source geometries reduce TCS CFs by 5%–11% compared to point sources across all configurations, highlighting the mitigating effect of distributed sources. Energy-dependent behavior is also evident: the 609.3 keV line exhibits strong summing-in (CF > 1.3 for large detectors), while the 1377.7 keV line shows dominant summing-out (CF < 0.86). These findings provide gamma-ray spectrometrists with insight into the relative importance of detector dimensions for TCS effects, suggesting that crystal radius is the primary geometric parameter influencing coincidence summing corrections. The observed trends illustrate how TCS corrections vary with detector dimensions, offering spectrometrists a basis for understanding the relative sensitivity of these corrections to different geometric parameters.

  • MakaleYayıncıda açık erişim2025
    A quantitative analysis on the effect of crystal parameters on full energy peak efficiency of a coaxial high purity Germanium detector for the energy range 50 keV-2.5 MeV

    Çelik, Necati

    High Purity Germanium (HPGe) detectors are essential instruments in gamma-ray spectrometry, offering high sensitivity and exceptional energy resolution. The full-energy-peak (FEP) efficiency is a critical parameter that influences the accuracy of activity concentration measurements of radionuclides. This study examines the FEP efficiency of a coaxial HPGe detector, focusing on variations in crystal length, crystal radius, and crystal hole dimensions. For varying crystal lengths, the efficiency values show negligible differences at low energy (50 keV) but significant increases at higher energies, indicating that longer crystal lengths enhance efficiency. Similarly, the efficiency increases with larger crystal radii across all energy levels suggesting substantial efficiency gains even at low energies. However, variations in crystal hole radius and depth, exhibit minimal impact on FEP efficiency across all tested energy levels. These findings highlight that optimizing crystal length and radius is more crucial for changing detector efficiency compared to modifying hole dimensions, providing valuable insights for optimizing Monte Carlo models and detector design.