- MakaleYalnız künye2026Optimizing compton suppression systems: A parametric monte carlo study of NaI scintillator geometry
Kaya, Ali; Çelik, Necati; Kaya, Selim
Compton suppression systems are widely used to enhance gamma-ray spectral quality in applications such as nuclear safeguards and environmental radioactivity measurements. Although optimization of high-purity germanium (HPGe) detectors has been extensively reported, the geometric optimization of secondary sodium iodide [NaI(Tl)] scintillation detectors remains less studied. This work investigates the influence of annular and plug NaI(Tl) detector geometry—length, thickness, and radius—on Compton suppression performance using Monte Carlo simulations. Performance is evaluated in terms of the peak Compton suppression factor (CSFpeak) and total Compton suppression factor (CSFtotal). The results show that CSFpeak and CSFtotal increase with plug length (2–10.2 cm) and annular thickness (1–5.85 cm), with saturation observed beyond approximately 8–10 cm and 4–5 cm, respectively, due to reduced incremental photon absorption. The plug detector radius (3.72–5.1 cm) exhibits a nonlinear effect, with optimal performance achieved at 4.55–4.83 cm, beyond which gains are marginal (<5%). Suboptimal geometries (plug length <6 cm, annular thickness <3 cm, plug radius <4.28 cm) result in 20–60% lower suppression performance, increasing Compton continuum contributions in 662 keV spectra. The optimal configuration—plug length of 8–10 cm, plug radius of 4.55–4.83 cm, and annular thickness of 4–5 cm—achieves more than 90% of maximum CSFpeak and CSFtotal while maintaining a balance between performance and detector volume. These results provide quantitative design guidelines for optimizing NaI(Tl)-based Compton suppression systems for improved gamma-ray spectrometry performance.
- MakaleYalnız künye2012Virtual point detector for HPGe detectors for 26.6-1332 keV photon energies by experiment and Monte Carlo simulation
Çelik, N.; Çevik, U.; Küçükömeroğlu, B.
Variation of virtual point detector (VPD) position inside HPGe detector as a function of source photon energy for the energy range from 26.6 to 1,332 keV was investigated. Although VPD concept was well established for HPGe detectors from 59.5 to 10 MeV, a new attempt was made to obtain VPD positions for photon energies below 59.5 keV. It was found that VPD position shows different functional behavior for the energy ranges 26.6-59.5 keV and 59.5-1,332 keV. The VPD position decreases with increasing energy for 26.6, 31.7, 36.4, and 37.3 keV and increases with the energy until it reaches a plateau. The functional behavior of VPD position for the energy range 26.6-59.5 keV was attributed to the dead layer thickness of the Ge crystal. Monte Carlo simulations were performed to investigate the behavior of VPD position with various dead layer thickness ranging from 100 to 800 μm. It was seen that VPD position increases with increasing energy for 31.7, 59.5, and 80.1 keV more significant at relatively lower energies, but constant for the energies 661-1,332 keV.