A novel cloud point extraction method using a benzimidazole-based ligand for the preconcentration of toxic heavy metals in water and food samples

MakaleAçık ErişimScopus SJRQ2
  • SDG 6 · Temiz Su ve Sanitasyon

Özet

In the present research, a novel cloud point extraction (CPE) method was developed for the separation and preconcentration of toxic Cu(ii), Ni(ii), Pb(ii), and Cd(ii) ions in environmental water and vegetable samples, prior to their determination by flame atomic absorption spectrometry (FAAS). The ligand 2-(2-(4-fluorobenzyl)-1H-benzo[d]imidazole-1-yl)acetohydrazide (FB-BIAH) was employed for the first time as an analytical complexing agent for the aforementioned metal ions, and Triton X-114 (TX-114) was preferred as the nonionic surfactant. Within the scope of optimizing CPE conditions, experimental parameters, such as pH, FB-BIAH and surfactant amounts, and incubation temperature and time, as well as centrifugation speed and duration, were systematically investigated. The optimal conditions for the simultaneous quantitative recovery of analyte ions were established as pH 7.0, an FB-BIAH amount of 2.5 mg, a TX-114 quantity of 25 mg, an incubation temperature of 60 °C, and an incubation time of 30 min. Under optimal conditions, the proposed method was successfully applied to river water and seawater, as well as different vegetable samples such as lettuce, parsley, and pepper. The results obtained demonstrated that the analyte ions could be reliably determined in complex matrices and that the method exhibited high analytical performance. Due to its simplicity, rapid applicability, environmentally friendly nature, and cost-effectiveness, the proposed CPE-FAAS method represents a promising approach for the routine analysis of toxic heavy metals in environmental water and food samples. This journal is

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13917Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1039/d6ay00036cYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
2
OpenAlex
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzdemir, Olcay
dc.contributor.authorDuran, Celal
dc.contributor.authorMentese, Emre
dc.contributor.authorOzdes, Duygu
dc.date.accessioned2026-10-22T10:21:57.326084117Z
dc.date.available2026-10-22T10:21:57.326084117Z
dc.date.issued2026
dc.description.abstractIn the present research, a novel cloud point extraction (CPE) method was developed for the separation and preconcentration of toxic Cu(ii), Ni(ii), Pb(ii), and Cd(ii) ions in environmental water and vegetable samples, prior to their determination by flame atomic absorption spectrometry (FAAS). The ligand 2-(2-(4-fluorobenzyl)-1H-benzo[d]imidazole-1-yl)acetohydrazide (FB-BIAH) was employed for the first time as an analytical complexing agent for the aforementioned metal ions, and Triton X-114 (TX-114) was preferred as the nonionic surfactant. Within the scope of optimizing CPE conditions, experimental parameters, such as pH, FB-BIAH and surfactant amounts, and incubation temperature and time, as well as centrifugation speed and duration, were systematically investigated. The optimal conditions for the simultaneous quantitative recovery of analyte ions were established as pH 7.0, an FB-BIAH amount of 2.5 mg, a TX-114 quantity of 25 mg, an incubation temperature of 60 °C, and an incubation time of 30 min. Under optimal conditions, the proposed method was successfully applied to river water and seawater, as well as different vegetable samples such as lettuce, parsley, and pepper. The results obtained demonstrated that the analyte ions could be reliably determined in complex matrices and that the method exhibited high analytical performance. Due to its simplicity, rapid applicability, environmentally friendly nature, and cost-effectiveness, the proposed CPE-FAAS method represents a promising approach for the routine analysis of toxic heavy metals in environmental water and food samples. This journal is
dc.identifier.doi10.1039/d6ay00036c
dc.identifier.eissn1759-9679
dc.identifier.endpage1617
dc.identifier.issn1759-9660
dc.identifier.issue8
dc.identifier.pmid41661034
dc.identifier.scopus2-s2.0-105029474559
dc.identifier.startpage1610
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13917
dc.identifier.volume18
dc.identifier.wosWOS:001684345400001
dc.language.isoen
dc.publisherRoyal Society of Chemistry
dc.relation.ispartofAnalytical Methods
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.classificationChemistry, Analytical
dc.subject.classificationFood Science & Technology
dc.subject.classificationSpectroscopy
dc.subject.classificationChemistry
dc.subject.otherBenzimidazoles
dc.subject.otherChemical Fractionation
dc.subject.otherFood Analysis
dc.subject.otherHydrogen-Ion Concentration
dc.subject.otherLigands
dc.subject.otherMetals, Heavy
dc.subject.otherOctoxynol
dc.subject.otherSpectrophotometry, Atomic
dc.subject.otherTemperature
dc.subject.otherVegetables
dc.subject.otherWater Pollutants, Chemical
dc.subject.otherChemical contamination
dc.subject.otherCopper compounds
dc.subject.otherCost benefit analysis
dc.subject.otherCost effectiveness
dc.subject.otherExtraction
dc.subject.otherLead compounds
dc.subject.otherMetal analysis
dc.subject.otherMetal ions
dc.subject.otherNonionic surfactants
dc.subject.otherWater absorption
dc.subject.otherbenzimidazole
dc.subject.otherbenzimidazole derivative
dc.subject.otherheavy metal
dc.subject.otherligand
dc.subject.otherNonidet P-40
dc.subject.otheroctoxinol
dc.subject.otherAcetohydrazide
dc.subject.otherCloud point extractions
dc.subject.otherEnvironmental water samples
dc.subject.otherExtraction method
dc.subject.otherFlame atomic absorption spectrometry
dc.subject.otherFood samples
dc.subject.otherImidazol
dc.subject.otherPre-concentration
dc.subject.otherToxic heavy metals
dc.subject.otherVegetable samples
dc.subject.otheratomic spectrometry
dc.subject.otherchemistry
dc.subject.otherfractionation
dc.subject.otherisolation and purification
dc.subject.otherpH
dc.subject.otherprocedures
dc.subject.othervegetable
dc.subject.otherwater pollutant
dc.subject.otherAtomic absorption spectrometry
dc.titleA novel cloud point extraction method using a benzimidazole-based ligand for the preconcentration of toxic heavy metals in water and food samples
dc.typeArticle
rdl.citation.openalex3
rdl.citation.scopus2
rdl.citation.wos2
rdl.departmentGumushane University, Gumushane Vocational School, 29100, Gumushane, Turkey
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.1039/d6ay00036c
rdl.scopus.quartileQ2
rdl.sdgSDG06
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)