The effect of TiO2 coating on biological NiTi alloys after micro-arc oxidation treatment for corrosion resistance
Özet
NiTi alloys exhibit good properties, such as shape memory behavior, high corrosion resistant, having the closest elasticity modulus of a human bone and superior biocompatibility properties. However, the surface problems that arise during the use of this alloy limit the usage in the industry and health sector. In recent years, micro-arc oxidation method is used to improve the surface properties and increase the usage of these alloys. In this study, the TiO2 coatings were deposited on the NiTi substrates. The surface topography, morphology, crystallographic structure, and thickness of the coatings were determined using scanning electron microscopy and X-ray diffraction. The corrosion properties were investigated using potentiostat test unit in two different media such as NaCl solution and simulated body fluid. The results show that the coated samples have higher corrosion resistance than uncoated samples in the two different media.
Anahtar Kelimeler
- Scopus
- 10
- WoS
- 11
- OpenAlex
- 11
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Sukuroglu, Ebru Emine | |
| dc.contributor.author | Sukuroglu, Suleyman | |
| dc.contributor.author | Akar, Kubra | |
| dc.contributor.author | Totik, Yasar | |
| dc.contributor.author | Efeoglu, Ihsan | |
| dc.contributor.author | Arslan, Ersin | |
| dc.date.accessioned | 2026-10-22T10:21:35.943810054Z | |
| dc.date.available | 2026-10-22T10:21:35.943810054Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | NiTi alloys exhibit good properties, such as shape memory behavior, high corrosion resistant, having the closest elasticity modulus of a human bone and superior biocompatibility properties. However, the surface problems that arise during the use of this alloy limit the usage in the industry and health sector. In recent years, micro-arc oxidation method is used to improve the surface properties and increase the usage of these alloys. In this study, the TiO2 coatings were deposited on the NiTi substrates. The surface topography, morphology, crystallographic structure, and thickness of the coatings were determined using scanning electron microscopy and X-ray diffraction. The corrosion properties were investigated using potentiostat test unit in two different media such as NaCl solution and simulated body fluid. The results show that the coated samples have higher corrosion resistance than uncoated samples in the two different media. | |
| dc.identifier.doi | 10.1177/0954411917705909 | |
| dc.identifier.eissn | 2041-3033 | |
| dc.identifier.endpage | 704 | |
| dc.identifier.issn | 0954-4119 | |
| dc.identifier.issue | 8 | |
| dc.identifier.pmid | 28452254 | |
| dc.identifier.scopus | 2-s2.0-85027140786 | |
| dc.identifier.startpage | 699 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/13635 | |
| dc.identifier.volume | 231 | |
| dc.identifier.wos | WOS:000407110500003 | |
| dc.language.iso | en | |
| dc.publisher | SAGE Publications Ltd | |
| dc.relation.ispartof | Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | corrosion resistant | |
| dc.subject | Micro-arc oxidation | |
| dc.subject | NiTi alloy | |
| dc.subject | simulated body fluid | |
| dc.subject | surface coating | |
| dc.subject.classification | Engineering, Biomedical | |
| dc.subject.classification | Engineering | |
| dc.subject.other | Alloys | |
| dc.subject.other | Biomimetic Materials | |
| dc.subject.other | Corrosion | |
| dc.subject.other | Oxidation-Reduction | |
| dc.subject.other | Sodium Chloride | |
| dc.subject.other | Titanium | |
| dc.subject.other | Binary alloys | |
| dc.subject.other | Biocompatibility | |
| dc.subject.other | Body fluids | |
| dc.subject.other | Coatings | |
| dc.subject.other | Corrosion resistance | |
| dc.subject.other | Corrosion resistant alloys | |
| dc.subject.other | Metal implants | |
| dc.subject.other | Nickel alloys | |
| dc.subject.other | Oxidation | |
| dc.subject.other | Scanning electron microscopy | |
| dc.subject.other | Surface topography | |
| dc.subject.other | Voltage regulators | |
| dc.subject.other | X ray diffraction | |
| dc.subject.other | alloy | |
| dc.subject.other | biomimetic material | |
| dc.subject.other | nitinol | |
| dc.subject.other | titanium dioxide | |
| dc.subject.other | Corrosion-resistant | |
| dc.subject.other | Microarc oxidation | |
| dc.subject.other | NiTi alloys | |
| dc.subject.other | Simulated body fluids | |
| dc.subject.other | Surface coatings | |
| dc.subject.other | chemistry | |
| dc.subject.other | oxidation reduction reaction | |
| dc.subject.other | Titanium alloys | |
| dc.title | The effect of TiO2 coating on biological NiTi alloys after micro-arc oxidation treatment for corrosion resistance | |
| dc.type | Article | |
| rdl.citation.openalex | 11 | |
| rdl.citation.scopus | 10 | |
| rdl.citation.wos | 11 | |
| rdl.department | 1 Department of Mechanical Engineering, Faculty of Engineering, Gümüşhane University, Gümüşhane, Turkey | |
| rdl.department | 2 Vocational College of Gümüşhane, Gümüşhane University, Gümüşhane, Turkey | |
| rdl.oa.status | closed | |
| rdl.scopus.quartile | Q2 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |