The effect of TiO2 coating on biological NiTi alloys after micro-arc oxidation treatment for corrosion resistance

MakaleYalnız künyeScopus SJRQ2

Özet

NiTi alloys exhibit good properties, such as shape memory behavior, high corrosion resistant, having the closest elasticity modulus of a human bone and superior biocompatibility properties. However, the surface problems that arise during the use of this alloy limit the usage in the industry and health sector. In recent years, micro-arc oxidation method is used to improve the surface properties and increase the usage of these alloys. In this study, the TiO2 coatings were deposited on the NiTi substrates. The surface topography, morphology, crystallographic structure, and thickness of the coatings were determined using scanning electron microscopy and X-ray diffraction. The corrosion properties were investigated using potentiostat test unit in two different media such as NaCl solution and simulated body fluid. The results show that the coated samples have higher corrosion resistance than uncoated samples in the two different media.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13635Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/0954411917705909Yayıncı resmi DOI adresi
Atıflar
Scopus
10
WoS
11
OpenAlex
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSukuroglu, Ebru Emine
dc.contributor.authorSukuroglu, Suleyman
dc.contributor.authorAkar, Kubra
dc.contributor.authorTotik, Yasar
dc.contributor.authorEfeoglu, Ihsan
dc.contributor.authorArslan, Ersin
dc.date.accessioned2026-10-22T10:21:35.943810054Z
dc.date.available2026-10-22T10:21:35.943810054Z
dc.date.issued2017
dc.description.abstractNiTi alloys exhibit good properties, such as shape memory behavior, high corrosion resistant, having the closest elasticity modulus of a human bone and superior biocompatibility properties. However, the surface problems that arise during the use of this alloy limit the usage in the industry and health sector. In recent years, micro-arc oxidation method is used to improve the surface properties and increase the usage of these alloys. In this study, the TiO2 coatings were deposited on the NiTi substrates. The surface topography, morphology, crystallographic structure, and thickness of the coatings were determined using scanning electron microscopy and X-ray diffraction. The corrosion properties were investigated using potentiostat test unit in two different media such as NaCl solution and simulated body fluid. The results show that the coated samples have higher corrosion resistance than uncoated samples in the two different media.
dc.identifier.doi10.1177/0954411917705909
dc.identifier.eissn2041-3033
dc.identifier.endpage704
dc.identifier.issn0954-4119
dc.identifier.issue8
dc.identifier.pmid28452254
dc.identifier.scopus2-s2.0-85027140786
dc.identifier.startpage699
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13635
dc.identifier.volume231
dc.identifier.wosWOS:000407110500003
dc.language.isoen
dc.publisherSAGE Publications Ltd
dc.relation.ispartofProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectcorrosion resistant
dc.subjectMicro-arc oxidation
dc.subjectNiTi alloy
dc.subjectsimulated body fluid
dc.subjectsurface coating
dc.subject.classificationEngineering, Biomedical
dc.subject.classificationEngineering
dc.subject.otherAlloys
dc.subject.otherBiomimetic Materials
dc.subject.otherCorrosion
dc.subject.otherOxidation-Reduction
dc.subject.otherSodium Chloride
dc.subject.otherTitanium
dc.subject.otherBinary alloys
dc.subject.otherBiocompatibility
dc.subject.otherBody fluids
dc.subject.otherCoatings
dc.subject.otherCorrosion resistance
dc.subject.otherCorrosion resistant alloys
dc.subject.otherMetal implants
dc.subject.otherNickel alloys
dc.subject.otherOxidation
dc.subject.otherScanning electron microscopy
dc.subject.otherSurface topography
dc.subject.otherVoltage regulators
dc.subject.otherX ray diffraction
dc.subject.otheralloy
dc.subject.otherbiomimetic material
dc.subject.othernitinol
dc.subject.othertitanium dioxide
dc.subject.otherCorrosion-resistant
dc.subject.otherMicroarc oxidation
dc.subject.otherNiTi alloys
dc.subject.otherSimulated body fluids
dc.subject.otherSurface coatings
dc.subject.otherchemistry
dc.subject.otheroxidation reduction reaction
dc.subject.otherTitanium alloys
dc.titleThe effect of TiO2 coating on biological NiTi alloys after micro-arc oxidation treatment for corrosion resistance
dc.typeArticle
rdl.citation.openalex11
rdl.citation.scopus10
rdl.citation.wos11
rdl.department1 Department of Mechanical Engineering, Faculty of Engineering, Gümüşhane University, Gümüşhane, Turkey
rdl.department2 Vocational College of Gümüşhane, Gümüşhane University, Gümüşhane, Turkey
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)