A new colorimetric method for CUPRAC assay with using of TLC plate

MakaleYalnız künyeScopus SJRQ1

Özet

Cupric reducing antioxidant capacity (CUPRAC) method is one of the most widely used antioxidant methods. However, its need for a spectrophotometer, as in many other methods, is an important disadvantage. Cupric reducing antioxidant capacity was determined based on color analysis with Image J program in computer with the new method developed in this study and thus, use of spectrophotometer was eliminated. The new colorimetric CUPRAC assay was applied to various standard antioxidants and plant extracts. The reaction mixtures were dropped on TLC plate. The colors formed on TLC were transferred to the computer by using scanner images, and CTEAC value in μmol/L of each sample was determined with the image J program. The CTEAC values were compared with the TEAC values measured with the spectrometric method. A linear relationship was found between both (C)TEAC values of antioxidant standards (R2 = 0.991) and plant extracts (R2 = 0.994). Thus, the new method developed for the CUPRAC antioxidant assay can be easily performed in any environment without spectrophotometer device, and it is a low-cost method.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/11388Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.lwt.2019.05.110Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
17
WoS
15
OpenAlex
25
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkar, Zeynep
dc.contributor.authorBurnaz, Nesibe Arslan
dc.date.accessioned2026-10-22T10:18:58.085732392Z
dc.date.available2026-10-22T10:18:58.085732392Z
dc.date.issued2019
dc.description.abstractCupric reducing antioxidant capacity (CUPRAC) method is one of the most widely used antioxidant methods. However, its need for a spectrophotometer, as in many other methods, is an important disadvantage. Cupric reducing antioxidant capacity was determined based on color analysis with Image J program in computer with the new method developed in this study and thus, use of spectrophotometer was eliminated. The new colorimetric CUPRAC assay was applied to various standard antioxidants and plant extracts. The reaction mixtures were dropped on TLC plate. The colors formed on TLC were transferred to the computer by using scanner images, and CTEAC value in μmol/L of each sample was determined with the image J program. The CTEAC values were compared with the TEAC values measured with the spectrometric method. A linear relationship was found between both (C)TEAC values of antioxidant standards (R2 = 0.991) and plant extracts (R2 = 0.994). Thus, the new method developed for the CUPRAC antioxidant assay can be easily performed in any environment without spectrophotometer device, and it is a low-cost method.
dc.description.sponsorshipGümüşhane University
dc.identifier.articlenumber108212
dc.identifier.doi10.1016/j.lwt.2019.05.110
dc.identifier.eissn1096-1127
dc.identifier.issn0023-6438
dc.identifier.scopus2-s2.0-85067014476
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/11388
dc.identifier.volume112
dc.identifier.wosWOS:000476965700018
dc.language.isoen
dc.publisherAcademic Press
dc.relation.ispartofLWT
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAntioxidant
dc.subjectColorimetric
dc.subjectCUPRAC
dc.subjectImage J
dc.subjectTLC plate
dc.subject.classificationFood Science & Technology
dc.subject.otherColor
dc.subject.otherColorimetry
dc.subject.otherMeteorological instruments
dc.subject.otherPlant extracts
dc.subject.otherSpectrophotometers
dc.subject.otherAntioxidant assays
dc.subject.otherAntioxidant capacity
dc.subject.otherColorimetric
dc.subject.otherColorimetric methods
dc.subject.otherCUPRAC
dc.subject.otherImage J
dc.subject.otherLinear relationships
dc.subject.otherSpectrometric methods
dc.subject.otherAntioxidants
dc.titleA new colorimetric method for CUPRAC assay with using of TLC plate
dc.typeArticle
rdl.citation.openalex25
rdl.citation.scopus17
rdl.citation.wos15
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)