Dc regulation and loop gain analysis of a dc-dc switch mode power supply: a case study on a synchronous pwm controlled buck converter

MakaleAçık Erişim

Özet

This study investigates the DC regulation of a DC-DC buck converter operating with pulse width modulation (PWM), taking into account the internal resistance of the coil and the on-resistance of the switching device. The effect of these parameters on the input/output disturbances is analyzed in continuous-conduction mode under constant frequency voltage mode control. The study also explores the effect on loop gain using the IRU3037 8-pin IC synchronous PWM controlled buck converter. The transfer function of the IRU3037 IC is derived from datasheet values using state-space averaging and AC small signal methods. A Type II compensator is then designed based on the derived transfer function. In addition, the step response characteristics of the open-loop and closed-loop circuits are investigated by time domain analysis.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/19994Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltan, Aytaç
dc.contributor.authorYanarates, Cagfer
dc.date.accessioned2026-10-22T10:52:46.090510626Z
dc.date.available2026-10-22T10:52:46.090510626Z
dc.date.issued2024
dc.description.abstractThis study investigates the DC regulation of a DC-DC buck converter operating with pulse width modulation (PWM), taking into account the internal resistance of the coil and the on-resistance of the switching device. The effect of these parameters on the input/output disturbances is analyzed in continuous-conduction mode under constant frequency voltage mode control. The study also explores the effect on loop gain using the IRU3037 8-pin IC synchronous PWM controlled buck converter. The transfer function of the IRU3037 IC is derived from datasheet values using state-space averaging and AC small signal methods. A Type II compensator is then designed based on the derived transfer function. In addition, the step response characteristics of the open-loop and closed-loop circuits are investigated by time domain analysis.
dc.identifier.doi10.34248/bsengineering.1532974
dc.identifier.eissn2619-8991
dc.identifier.endpage1021
dc.identifier.issue5
dc.identifier.startpage1014
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/19994
dc.identifier.volume7
dc.language.isoen
dc.relation.ispartofBlack Sea Journal of Engineering and Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMühendislik, Elektrik ve Elektronik
dc.titleDc regulation and loop gain analysis of a dc-dc switch mode power supply: a case study on a synchronous pwm controlled buck converter
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex1
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/4143928
rdl.source.indexTRDIZIN