Selective separation, preconcentration and determination of Pd(II) ions in environmental samples by coprecipitation with a 1,2,4-triazole derivative

MakaleAçık ErişimScopus SJRQ3

Özet

A simple, sensitive, facile and low cost methodology, combined with flame atomic absorption spectrometry (FAAS), was employed to evaluate the selective separation and preconcentration of Pd(II) ions in environmental samples by using a triazole derivative as an organic coprecipitating agent without a carrier element. The developed method was systematically investigated in different set of experimental parameters that influence the quantitative recovery of Pd(II) ions. The accuracy of the method was tested by analyzing certified reference material and spike tests. The developed coprecipitation procedure has been applied to road dust, anodic slime, industrial electronic waste materials and water samples to determine their Pd(II) levels.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15698Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4314/bcse.v29i1.1Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
12
WoS
12
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzdes, Duygu
dc.contributor.authorDuran, Celal
dc.contributor.authorSerencam, Huseyin
dc.contributor.authorSahin, Deniz
dc.contributor.authorGundogdu, Ali
dc.contributor.authorSoylak, Mustafa
dc.date.accessioned2026-10-22T10:24:24.033408427Z
dc.date.available2026-10-22T10:24:24.033408427Z
dc.date.issued2015
dc.description.abstractA simple, sensitive, facile and low cost methodology, combined with flame atomic absorption spectrometry (FAAS), was employed to evaluate the selective separation and preconcentration of Pd(II) ions in environmental samples by using a triazole derivative as an organic coprecipitating agent without a carrier element. The developed method was systematically investigated in different set of experimental parameters that influence the quantitative recovery of Pd(II) ions. The accuracy of the method was tested by analyzing certified reference material and spike tests. The developed coprecipitation procedure has been applied to road dust, anodic slime, industrial electronic waste materials and water samples to determine their Pd(II) levels.
dc.identifier.doi10.4314/bcse.v29i1.1
dc.identifier.eissn1726-801X
dc.identifier.endpage10
dc.identifier.issn1011-3924
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84921295024
dc.identifier.startpage1
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15698
dc.identifier.volume29
dc.identifier.wosWOS:000357403500001
dc.language.isoen
dc.publisherChemical Society of Ethiopia
dc.relation.ispartofBulletin of the Chemical Society of Ethiopia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCarrier element free coprecipitation
dc.subjectPalladium
dc.subjectPreconcentration
dc.subjectSeparation
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationChemistry
dc.subject.otherATOMIC-ABSORPTION-SPECTROMETRY
dc.subject.otherPLASMA-MASS-SPECTROMETRY
dc.subject.otherPLATINUM-GROUP ELEMENTS
dc.subject.otherCLOUD POINT EXTRACTION
dc.subject.otherCARRIER ELEMENT
dc.subject.otherWATER SAMPLES
dc.subject.otherHYDRIDE GENERATION
dc.subject.otherBIOLOGICAL SAMPLES
dc.subject.otherCU(II) IONS
dc.subject.otherSOLID-PHASE
dc.titleSelective separation, preconcentration and determination of Pd(II) ions in environmental samples by coprecipitation with a 1,2,4-triazole derivative
dc.typeArticle
rdl.citation.scopus12
rdl.citation.wos12
rdl.oa.statusgold
rdl.oa.urlhttps://www.ajol.info/index.php/bcse/article/download/111459/101235
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)