A proficiency test scheme for the quality control of black tea and development of quality control material for internal quality control

MakaleYalnız künye

Özet

A proficiency test (PT) was organized for quality control analysis of black tea. Test materials for the analyses of total content of powder tea, moisture, total ash, acid-insoluble ash, water-soluble ash, alkalinity of water-soluble ash, water extract, crude fiber and caffeine were sent to the participant laboratories (n:43) in 2009. The assigned value, standard deviation of the parameters and z-scores of the participant laboratories were calculated using the data reported by the participants. The percentage of the reported results for analytes was found to be ranged from 67.5 to 100%. Acceptable z-scores were achieved by 80.5-97.5% of the participant laboratories. More than 15% of unacceptable results were obtained for acid-insoluble ash and caffeine analyses. The quality control material for quality control analysis of black tea was developed from the remaining material.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15643Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s00769-011-0799-5Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBaltaci, Cemalettin
dc.contributor.authorIlyasoǧlu, Huri
dc.contributor.authorSarikaya, Sevim Beyza Öztürk
dc.contributor.authorCavrar, Sevda
dc.contributor.authorYayli, Nurettin
dc.date.accessioned2026-10-22T10:24:19.266753374Z
dc.date.available2026-10-22T10:24:19.266753374Z
dc.date.issued2011
dc.description.abstractA proficiency test (PT) was organized for quality control analysis of black tea. Test materials for the analyses of total content of powder tea, moisture, total ash, acid-insoluble ash, water-soluble ash, alkalinity of water-soluble ash, water extract, crude fiber and caffeine were sent to the participant laboratories (n:43) in 2009. The assigned value, standard deviation of the parameters and z-scores of the participant laboratories were calculated using the data reported by the participants. The percentage of the reported results for analytes was found to be ranged from 67.5 to 100%. Acceptable z-scores were achieved by 80.5-97.5% of the participant laboratories. More than 15% of unacceptable results were obtained for acid-insoluble ash and caffeine analyses. The quality control material for quality control analysis of black tea was developed from the remaining material.
dc.identifier.doi10.1007/s00769-011-0799-5
dc.identifier.eissn1432-0517
dc.identifier.endpage513
dc.identifier.issn0949-1775
dc.identifier.issue10
dc.identifier.scopus2-s2.0-80053094595
dc.identifier.startpage507
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15643
dc.identifier.volume16
dc.identifier.wosWOS:000295163600006
dc.language.isoen
dc.publisherSPRINGER
dc.relation.ispartofAccreditation and Quality Assurance
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBlack tea
dc.subjectProficiency test
dc.subjectQuality control material
dc.subjectz-score
dc.subject.classificationChemistry, Analytical
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationChemistry
dc.subject.otherHEALTH
dc.titleA proficiency test scheme for the quality control of black tea and development of quality control material for internal quality control
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex3
rdl.citation.scopus4
rdl.citation.wos3
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)