Effect of detector collimation on the measured mass attenuation coefficients of some elements for 59.5-661.6 keV gamma-rays

MakaleYalnız künye

Özet

Mass attenuation coefficients were determined experimentally for Sc, Ni and W for gamma energies of 59.5, 122, 276, 302, 356, 383 and 662 keV for different detector collimator diameters ranging from 2 to 10 mm. The aim was to investigate the quantitative analysis of detector collimator diameter effect on measured mass attenuation coefficients. It was found that measured mass attenuation coefficients decrease systematically with the increasing collimator diameter. The relative difference was found to be up to around 3% in some cases. The observed decrease in mass attenuation coefficients was attributed to the detection of elastic and inelastic scattered photons from the absorber. In elastic scattering process the photons change in direction but not in energy and get counted under the full energy peak if they reach the detector. In inelastic scattering however, both direction and energy of the scattered photons change. It was seen that most of the inelastic scattered photons also get counted by the detection system since they lose an amount of energy lower than the energy resolution of the detector. It is understood from the present results that it is essential to take into account the experimental geometry when reporting mass attenuation coefficients.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15516Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.nimb.2012.04.003Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇelik, Necati
dc.contributor.authorÇevik, Ugur
dc.contributor.authorÇelik, Ahmet
dc.date.accessioned2026-10-22T10:24:08.010452704Z
dc.date.available2026-10-22T10:24:08.010452704Z
dc.date.issued2012
dc.description.abstractMass attenuation coefficients were determined experimentally for Sc, Ni and W for gamma energies of 59.5, 122, 276, 302, 356, 383 and 662 keV for different detector collimator diameters ranging from 2 to 10 mm. The aim was to investigate the quantitative analysis of detector collimator diameter effect on measured mass attenuation coefficients. It was found that measured mass attenuation coefficients decrease systematically with the increasing collimator diameter. The relative difference was found to be up to around 3% in some cases. The observed decrease in mass attenuation coefficients was attributed to the detection of elastic and inelastic scattered photons from the absorber. In elastic scattering process the photons change in direction but not in energy and get counted under the full energy peak if they reach the detector. In inelastic scattering however, both direction and energy of the scattered photons change. It was seen that most of the inelastic scattered photons also get counted by the detection system since they lose an amount of energy lower than the energy resolution of the detector. It is understood from the present results that it is essential to take into account the experimental geometry when reporting mass attenuation coefficients.
dc.identifier.doi10.1016/j.nimb.2012.04.003
dc.identifier.eissn1872-9584
dc.identifier.endpage14
dc.identifier.issn0168-583X
dc.identifier.scopus2-s2.0-84861120226
dc.identifier.startpage8
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15516
dc.identifier.volume281
dc.identifier.wosWOS:000304895000002
dc.language.isoen
dc.publisherELSEVIER
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDetector collimation
dc.subjectMass attenuation coefficient
dc.subjectNi
dc.subjectSc
dc.subjectTransmission method
dc.subjectW
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationPhysics, Atomic, Molecular & Chemical
dc.subject.classificationPhysics, Nuclear
dc.subject.classificationPhysics
dc.subject.otherDetectors
dc.subject.otherGamma rays
dc.subject.otherLight scattering
dc.subject.otherNickel
dc.subject.otherScandium
dc.subject.otherTungsten
dc.subject.otherDetection system
dc.subject.otherDiameter effect
dc.subject.otherEnergy resolutions
dc.subject.otherFull energy peak
dc.subject.otherGamma energy
dc.subject.otherMass attenuation coefficients
dc.subject.otherScattered photons
dc.subject.otherRadiation
dc.titleEffect of detector collimation on the measured mass attenuation coefficients of some elements for 59.5-661.6 keV gamma-rays
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex13
rdl.citation.scopus10
rdl.citation.wos11
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)