    Enhancing precision of low-cost detectors via machine learning for accurate mass attenuation coefficient estimation

    Düzgün, İ.; Küçük, M.A.; Kaya, S.; Çelik, N.

    Low-cost NaI(Tl) detectors are practical for gamma-ray spectrometry but their limited energy resolution can introduce systematic errors in mass attenuation coefficient measurements when scattered photons are included in the peak region. This study proposes a machine-learning correction framework that maps NaI(Tl)-derived attenuation coefficients to XCOM-based HPGe-equivalent reference values through a dimensionless correction factor. An EGS4/XCOM dataset of 756 model-development configurations, covering 18 atomic numbers, six monoenergetic photon energies, and seven collimator radii, was used to train twelve regression models and evaluate them over 60 randomized train–validation–test cycles. Sodium and Bismuth were withheld for external material-wise validation. Gaussian Process Regression with a Matérn 5/2 kernel provided the best overall testing performance. For the withheld materials, the correction reduced the mean deviation from XCOM references from 3.07% to 0.83%, supporting its use as a practical correction layer for low-cost attenuation measurements.

  • MakaleYalnız künye2012Scopus SJRQ2
    Effect of detector collimation on the measured mass attenuation coefficients of some elements for 59.5-661.6 keV gamma-rays

    Çelik, Necati; Çevik, Ugur; Çelik, Ahmet

    Mass attenuation coefficients were determined experimentally for Sc, Ni and W for gamma energies of 59.5, 122, 276, 302, 356, 383 and 662 keV for different detector collimator diameters ranging from 2 to 10 mm. The aim was to investigate the quantitative analysis of detector collimator diameter effect on measured mass attenuation coefficients. It was found that measured mass attenuation coefficients decrease systematically with the increasing collimator diameter. The relative difference was found to be up to around 3% in some cases. The observed decrease in mass attenuation coefficients was attributed to the detection of elastic and inelastic scattered photons from the absorber. In elastic scattering process the photons change in direction but not in energy and get counted under the full energy peak if they reach the detector. In inelastic scattering however, both direction and energy of the scattered photons change. It was seen that most of the inelastic scattered photons also get counted by the detection system since they lose an amount of energy lower than the energy resolution of the detector. It is understood from the present results that it is essential to take into account the experimental geometry when reporting mass attenuation coefficients.

    AtıfScopus10WoS11OpenAlex13
    ScopusWeb of Scienceİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn0168-583X
dc.date.accessioned2026-10-22T10:21:32.733148677Z
dc.date.available2026-10-22T10:21:32.733148677Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13589
dc.publisherElsevier B.V.
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms