A rapid and sensitive spectrofluorometric method for the determination of au(III) based on fluorescence quenching of a 1,3,5-triphenyl-2-pyrazoline

MakaleAçık Erişim
  • SDG 6 · Temiz Su ve Sanitasyon

Özet

A simple, rapid, sensitive, and low-cost spectrofluorometric method was developed for the determination of Au(III) using 5-(2,3-dimethoxyphenyl)-3-(4-methoxyphenyl)-1-phenyl-4,5-dihydro-1H-pyrazole (L) in ethanol/water. The method is based on the change in the fluorescence intensity at 464 nm after excitation at 355 nm as a result of the reaction between the ligand and Au(III). The fluorescent emission of ligand at 464 nm decreased with the increasing of Au(III) concentration. The ligand concentration, pH effect, response time, and effect of foreign ions were determined. From the results of fluorescence titration experiments, it was found that the ligand (1 × 10−7 M) was selective and sensitive to Au(III) in EtOH-H2 O (1:1, v/v, phthalate buffer, pH 4.0). The calibration curve showed good linearity in the concentration range of 17.4–237.6 µg L−1 Au(III). The limits of detection and quantification were 5.2 and 17.4 µg L−1 Au(III) with a response time of 1 min, respectively. Satisfactory accuracy was obtained for standard reference material (CRM-SA-C Sandy Soil C). The proposed method was successfully applied to the determination of Au(III) in tap water, sea water, and stream water samples, and high levels of recovery were obtained.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15234Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3906/kim-1712-40Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBaşoğlu, Aysel
dc.contributor.authorOcak, Ümmühan
dc.contributor.authorFandakli, Seda
dc.contributor.authorYayli, Nurettin
dc.date.accessioned2026-10-22T10:23:45.586398521Z
dc.date.available2026-10-22T10:23:45.586398521Z
dc.date.issued2018
dc.description.abstractA simple, rapid, sensitive, and low-cost spectrofluorometric method was developed for the determination of Au(III) using 5-(2,3-dimethoxyphenyl)-3-(4-methoxyphenyl)-1-phenyl-4,5-dihydro-1H-pyrazole (L) in ethanol/water. The method is based on the change in the fluorescence intensity at 464 nm after excitation at 355 nm as a result of the reaction between the ligand and Au(III). The fluorescent emission of ligand at 464 nm decreased with the increasing of Au(III) concentration. The ligand concentration, pH effect, response time, and effect of foreign ions were determined. From the results of fluorescence titration experiments, it was found that the ligand (1 × 10−7 M) was selective and sensitive to Au(III) in EtOH-H2 O (1:1, v/v, phthalate buffer, pH 4.0). The calibration curve showed good linearity in the concentration range of 17.4–237.6 µg L−1 Au(III). The limits of detection and quantification were 5.2 and 17.4 µg L−1 Au(III) with a response time of 1 min, respectively. Satisfactory accuracy was obtained for standard reference material (CRM-SA-C Sandy Soil C). The proposed method was successfully applied to the determination of Au(III) in tap water, sea water, and stream water samples, and high levels of recovery were obtained.
dc.description.sponsorshipGümüşhane University Scientific Research Foundation
dc.description.sponsorshipFoundation for Dietary Scientific Research, (15.A0118.02.01)
dc.identifier.doi10.3906/kim-1712-40
dc.identifier.eissn1303-6130
dc.identifier.endpage1055
dc.identifier.issn1300-0527
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85073579050
dc.identifier.startpage1045
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15234
dc.identifier.volume42
dc.identifier.wosWOS:000440654100009
dc.language.isoen
dc.publisherTUBITAK
dc.relation.ispartofTurkish Journal of Chemistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject1
dc.subject3
dc.subject5-triphenyl-2-pyrazoline
dc.subjectFluorescence quenching
dc.subjectGold determination
dc.subjectSpectrofluorometric analysis
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationEngineering, Chemical
dc.subject.classificationChemistry
dc.subject.classificationEngineering
dc.subject.otherATOMIC-ABSORPTION-SPECTROMETRY
dc.subject.otherSPECTROPHOTOMETRIC METHOD
dc.subject.otherGOLD NANOPARTICLES
dc.subject.otherAQUEOUS-SOLUTION
dc.subject.otherCHARGE-TRANSFER
dc.subject.otherZN2+ ION
dc.subject.otherPYRAZOLINE
dc.subject.otherSAMPLES
dc.subject.otherSENSOR
dc.subject.otherCELLS
dc.titleA rapid and sensitive spectrofluorometric method for the determination of au(III) based on fluorescence quenching of a 1,3,5-triphenyl-2-pyrazoline
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex5
rdl.citation.scopus4
rdl.citation.trdizin1
rdl.citation.wos4
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.3906/kim-1712-40
rdl.sdgSDG06
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)