Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Aim: This study analyzed the concurrent validity of the Optojump infrared photocell system for estimating lower limb peak power by comparing it with the 15 s Wingate anaerobic test (WAnT) and examining relationships with sprint performance indicators. Methods: Twelve physically active university students (ten males, two females; age: 23.39 ± 1.47 years; body mass: 73.08 ± 9.19 kg; height: 173.67 ± 6.97 cm; BMI: 24.17 ± 1.48 kg·m−2) completed a cross-sectional validation protocol. Participants performed WAnT on a calibrated Monark ergometer (7.5% body weight for males, 5.5% for females), 30 s continuous jump tests using the Optojump system (Microgate, Italy), and 30 m sprint assessments with 10 m and 20 m split times. Peak power was expressed in absolute (W), relative (W·kg−1), and allometric (W·kg−0.67) terms. Results: Thirty-second continuous jump testing produced systematically higher peak power values across all metrics (p < 0.001). Mean differences indicated large effect sizes: relative power (Cohen’s d = 0.99; 18.263 ± 4.243 vs. 10.99 ± 1.58 W·kg−1), absolute power (d = 0.86; 1381.71 ± 393.44 vs. 807.28 ± 175.45 W), and allometric power (d = 0.79). Strong correlations emerged between protocols, with absolute power showing the strongest association (r = 0.842, p < 0.001). Linear regression analysis revealed that 30 s continuous jump-derived measurements explained 71% of the variance in Wingate outcomes (R2 = 0.710, p < 0.001). Sprint performance showed equivalent predictive capacity for both tests (Wingate: R2 = 0.66; 30 s continuous jump: R2 = 0.67). Conclusions: The Optojump infrared photocell system provides a valid and practical alternative to laboratory-based ergometry for assessing lower limb anaerobic power. While it systematically overestimates absolute values compared with the Wingate anaerobic test, its strong concurrent validity (r > 0.80), large effect sizes, and equivalent predictive ability for sprint performance (R2 = 0.66–0.71) confirm its reliability as a field-based assessment tool. These findings underscore the importance of sport-specific, weight-bearing assessment technologies in modern sports biomechanics, providing coaches, practitioners, and clinicians with a feasible method for monitoring performance, talent identification, and training optimization. The results further suggest that Optojump-based protocols can bridge the gap between laboratory precision and ecological validity, supporting both athletic performance enhancement and injury prevention strategies.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14096Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/app151910741Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
3
WoS
2
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKhemiri, Aymen
dc.contributor.authorNegra, Yassine
dc.contributor.authorCeylan, Halil İbrahim
dc.contributor.authorHajri, Manel
dc.contributor.authorNjah, Abdelmonom
dc.contributor.authorHachana, Younes
dc.contributor.authorYıldız, Mevlüt
dc.contributor.authorBayrakdaroğlu, Serdar
dc.contributor.authorMuntean, Raul Ioan
dc.contributor.authorAttia, Ahmed
dc.date.accessioned2026-10-22T10:22:14.412077795Z
dc.date.available2026-10-22T10:22:14.412077795Z
dc.date.issued2025
dc.description.abstractAim: This study analyzed the concurrent validity of the Optojump infrared photocell system for estimating lower limb peak power by comparing it with the 15 s Wingate anaerobic test (WAnT) and examining relationships with sprint performance indicators. Methods: Twelve physically active university students (ten males, two females; age: 23.39 ± 1.47 years; body mass: 73.08 ± 9.19 kg; height: 173.67 ± 6.97 cm; BMI: 24.17 ± 1.48 kg·m−2) completed a cross-sectional validation protocol. Participants performed WAnT on a calibrated Monark ergometer (7.5% body weight for males, 5.5% for females), 30 s continuous jump tests using the Optojump system (Microgate, Italy), and 30 m sprint assessments with 10 m and 20 m split times. Peak power was expressed in absolute (W), relative (W·kg−1), and allometric (W·kg−0.67) terms. Results: Thirty-second continuous jump testing produced systematically higher peak power values across all metrics (p < 0.001). Mean differences indicated large effect sizes: relative power (Cohen’s d = 0.99; 18.263 ± 4.243 vs. 10.99 ± 1.58 W·kg−1), absolute power (d = 0.86; 1381.71 ± 393.44 vs. 807.28 ± 175.45 W), and allometric power (d = 0.79). Strong correlations emerged between protocols, with absolute power showing the strongest association (r = 0.842, p < 0.001). Linear regression analysis revealed that 30 s continuous jump-derived measurements explained 71% of the variance in Wingate outcomes (R2 = 0.710, p < 0.001). Sprint performance showed equivalent predictive capacity for both tests (Wingate: R2 = 0.66; 30 s continuous jump: R2 = 0.67). Conclusions: The Optojump infrared photocell system provides a valid and practical alternative to laboratory-based ergometry for assessing lower limb anaerobic power. While it systematically overestimates absolute values compared with the Wingate anaerobic test, its strong concurrent validity (r > 0.80), large effect sizes, and equivalent predictive ability for sprint performance (R2 = 0.66–0.71) confirm its reliability as a field-based assessment tool. These findings underscore the importance of sport-specific, weight-bearing assessment technologies in modern sports biomechanics, providing coaches, practitioners, and clinicians with a feasible method for monitoring performance, talent identification, and training optimization. The results further suggest that Optojump-based protocols can bridge the gap between laboratory precision and ecological validity, supporting both athletic performance enhancement and injury prevention strategies.
dc.identifier.articlenumber10741
dc.identifier.doi10.3390/app151910741
dc.identifier.eissn2076-3417
dc.identifier.issn2076-3417
dc.identifier.issue19
dc.identifier.scopus2-s2.0-105032648848
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14096
dc.identifier.volume15
dc.identifier.wosWOS:001594665300001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofApplied Sciences (Switzerland)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectanaerobic power
dc.subjectathletic performance
dc.subjectfield-based assessment
dc.subjectoptojump
dc.subjectsports biomechanics
dc.subjectsprint performance
dc.subjectwingate anaerobic test
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationPhysics, Applied
dc.subject.classificationChemistry
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.classificationPhysics
dc.subject.otherBiomechanics
dc.subject.otherExercise equipment
dc.subject.otherLinear regression
dc.subject.otherAnaerobic power
dc.subject.otherAnaerobics
dc.subject.otherAthletic performance
dc.subject.otherField-based assessment
dc.subject.otherLower limb
dc.subject.otherOptojump
dc.subject.otherPerformance
dc.subject.otherSport biomechanics
dc.subject.otherSprint performance
dc.subject.otherWingate anerobic test
dc.subject.otherSports
dc.titleConcurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance
dc.typeArticle
rdl.citation.openalex2
rdl.citation.scopus3
rdl.citation.wos2
rdl.oa.statusgold
rdl.oa.urlhttps://www.mdpi.com/2076-3417/15/19/10741/pdf?version=1759724915
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)