Enhancing precision of low-cost detectors via machine learning for accurate mass attenuation coefficient estimation

MakaleAçık Erişim

Özet

Low-cost NaI(Tl) detectors are practical for gamma-ray spectrometry but their limited energy resolution can introduce systematic errors in mass attenuation coefficient measurements when scattered photons are included in the peak region. This study proposes a machine-learning correction framework that maps NaI(Tl)-derived attenuation coefficients to XCOM-based HPGe-equivalent reference values through a dimensionless correction factor. An EGS4/XCOM dataset of 756 model-development configurations, covering 18 atomic numbers, six monoenergetic photon energies, and seven collimator radii, was used to train twelve regression models and evaluate them over 60 randomized train–validation–test cycles. Sodium and Bismuth were withheld for external material-wise validation. Gaussian Process Regression with a Matérn 5/2 kernel provided the best overall testing performance. For the withheld materials, the correction reduced the mean deviation from XCOM references from 3.07% to 0.83%, supporting its use as a practical correction layer for low-cost attenuation measurements.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13588Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.nimb.2026.166338Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDüzgün, İ.
dc.contributor.authorKüçük, M.A.
dc.contributor.authorKaya, S.
dc.contributor.authorÇelik, N.
dc.date.accessioned2026-10-22T10:21:32.660677464Z
dc.date.available2026-10-22T10:21:32.660677464Z
dc.date.issued2026
dc.description.abstractLow-cost NaI(Tl) detectors are practical for gamma-ray spectrometry but their limited energy resolution can introduce systematic errors in mass attenuation coefficient measurements when scattered photons are included in the peak region. This study proposes a machine-learning correction framework that maps NaI(Tl)-derived attenuation coefficients to XCOM-based HPGe-equivalent reference values through a dimensionless correction factor. An EGS4/XCOM dataset of 756 model-development configurations, covering 18 atomic numbers, six monoenergetic photon energies, and seven collimator radii, was used to train twelve regression models and evaluate them over 60 randomized train–validation–test cycles. Sodium and Bismuth were withheld for external material-wise validation. Gaussian Process Regression with a Matérn 5/2 kernel provided the best overall testing performance. For the withheld materials, the correction reduced the mean deviation from XCOM references from 3.07% to 0.83%, supporting its use as a practical correction layer for low-cost attenuation measurements.
dc.identifier.articlenumber166338
dc.identifier.doi10.1016/j.nimb.2026.166338
dc.identifier.eissn1872-9584
dc.identifier.issn0168-583X
dc.identifier.scopus2-s2.0-105052748078
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13588
dc.identifier.volume581
dc.identifier.wosWOS:001901960600001
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEGS4
dc.subjectGaussian process regression
dc.subjectHPGe detector
dc.subjectMachine learning
dc.subjectMass attenuation coefficient
dc.subjectMonte Carlo simulation
dc.subjectNaI(Tl) detector
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationPhysics, Atomic, Molecular & Chemical
dc.subject.classificationPhysics, Nuclear
dc.subject.classificationPhysics
dc.subject.otherCosts
dc.subject.otherGamma ray spectrometers
dc.subject.otherGaussian distribution
dc.subject.otherGaussian noise (electronic)
dc.subject.otherGermanium compounds
dc.subject.otherIodine compounds
dc.subject.otherLearning systems
dc.subject.otherMachine learning
dc.subject.otherPhosphorus compounds
dc.subject.otherPhotons
dc.subject.otherRegression analysis
dc.subject.otherSodium Iodide
dc.subject.otherStatistical tests
dc.subject.otherSystematic errors
dc.subject.otherAccurate mass
dc.subject.otherEGS4
dc.subject.otherGamma rays spectrometries
dc.subject.otherGaussian process regression
dc.subject.otherHPGe detectors
dc.subject.otherLow-costs
dc.subject.otherMachine-learning
dc.subject.otherMass attenuation coefficients
dc.subject.otherMonte Carlo's simulation
dc.subject.otherNaI(tl) detector
dc.subject.otherMonte Carlo methods
dc.titleEnhancing precision of low-cost detectors via machine learning for accurate mass attenuation coefficient estimation
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.1016/j.nimb.2026.166338
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)