Immunosuppressant adherence levels in kidney transplant recipients measured by electronic monitoring devices: A systematic review and meta-analysis

Derleme MakaleYalnız künye
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Background: Kidney transplantation improves survival and quality of life in patients with end-stage renal disease; however, long-term graft success depends on adherence to immunosuppressive therapy. Objective: To quantify adherence levels among kidney transplant recipients using electronic monitoring devices. Methods: PubMed, Web of Science, Scopus, and the Cochrane Library were systematically searched for studies published between 2000 and 2025. A random-effects meta-analysis was conducted including studies that assessed adherence using electronic monitoring devices. Results: Seven studies with a total of 1025 kidney transplant recipients were included. The pooled mean adherence measured using electronic monitoring devices was 94.39%. In studies with monitoring durations of three months or longer, adherence decreased to 90.50%. Substantial heterogeneity was observed across studies. Conclusion: Although electronically measured adherence appears generally high, its decline over longer monitoring periods indicates that adherence is dynamic and may decrease over time. However, these estimates should be interpreted cautiously because electronic monitoring devices cannot confirm actual medication ingestion. Furthermore, intentionally non-adherent patients may be less likely to participate in or remain engaged with electronic monitoring studies and may therefore be underrepresented, potentially leading to an overestimation of true adherence. Even modest reductions in adherence may carry important clinical consequences, underscoring the need for sustained monitoring.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13413Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.trre.2026.101044Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTuncer, Metin
dc.contributor.authorYalcinkaya, Turgay
dc.contributor.authorErol, Ahmet
dc.contributor.authorÖzalp, Cemal
dc.date.accessioned2026-10-22T10:21:19.523890107Z
dc.date.available2026-10-22T10:21:19.523890107Z
dc.date.issued2026
dc.description.abstractBackground: Kidney transplantation improves survival and quality of life in patients with end-stage renal disease; however, long-term graft success depends on adherence to immunosuppressive therapy. Objective: To quantify adherence levels among kidney transplant recipients using electronic monitoring devices. Methods: PubMed, Web of Science, Scopus, and the Cochrane Library were systematically searched for studies published between 2000 and 2025. A random-effects meta-analysis was conducted including studies that assessed adherence using electronic monitoring devices. Results: Seven studies with a total of 1025 kidney transplant recipients were included. The pooled mean adherence measured using electronic monitoring devices was 94.39%. In studies with monitoring durations of three months or longer, adherence decreased to 90.50%. Substantial heterogeneity was observed across studies. Conclusion: Although electronically measured adherence appears generally high, its decline over longer monitoring periods indicates that adherence is dynamic and may decrease over time. However, these estimates should be interpreted cautiously because electronic monitoring devices cannot confirm actual medication ingestion. Furthermore, intentionally non-adherent patients may be less likely to participate in or remain engaged with electronic monitoring studies and may therefore be underrepresented, potentially leading to an overestimation of true adherence. Even modest reductions in adherence may carry important clinical consequences, underscoring the need for sustained monitoring.
dc.identifier.articlenumber101044
dc.identifier.doi10.1016/j.trre.2026.101044
dc.identifier.issn0955-470X
dc.identifier.issue4
dc.identifier.pmid42508234
dc.identifier.scopus2-s2.0-105045477251
dc.identifier.startpage101044
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13413
dc.identifier.volume40
dc.identifier.wosWOS:001835741200001
dc.language.isoen
dc.publisherElsevier Inc.
dc.relation.ispartofTransplantation Reviews
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectElectronic monitoring
dc.subjectKidney transplantation
dc.subjectMedication adherence
dc.subjectMeta-analysis
dc.subject.classificationImmunology
dc.subject.classificationTransplantation
dc.subject.otherimmunosuppressive agent
dc.subject.otherCochrane Library
dc.subject.otherend stage renal disease
dc.subject.othergraft recipient
dc.subject.otherhuman
dc.subject.otherimmunosuppressive treatment
dc.subject.otherkidney graft
dc.subject.otherkidney graft rejection
dc.subject.othermedication compliance
dc.subject.otherMedline
dc.subject.othermeta analysis
dc.subject.otherpatient compliance
dc.subject.otherpatient monitoring
dc.subject.otherquality control
dc.subject.otherquality of life
dc.subject.otherReview
dc.subject.otherScopus
dc.subject.othersystematic review
dc.subject.othertrend study
dc.subject.otherWeb of Science
dc.titleImmunosuppressant adherence levels in kidney transplant recipients measured by electronic monitoring devices: A systematic review and meta-analysis
dc.typeReview Article
dspace.entity.typePublication
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.departmentAssistant Professor, Department of Fundamentals of Nursing, Faculty of Health Sciences, Gümüşhane University, Gümüşhane, Türkiye
rdl.oa.statusclosed
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)