Finite element model calibration of berke arch dam using operational modal testing

MakaleYalnız künye

Özet

This paper presents the finite element calibration of Berke Arch Dam by using Operational Modal Testing. Achievement of this purpose involves structural vibration characteristics of Berke Arch Dam using analytical and Operational Modal Analyses. Therefore, the study has two parts-analytical and experimental. In the analytical part of the study, the authors developed a 3D finite element model of Berke Arch Dam-reservoir-foundation system using ANSYS software, and analytically determined vibration characteristics such as natural frequencies and mode shapes. In the experimental part of the study, sensitive accelerometers were placed to several points of Berke Arch Dam, and ambient vibration tests were conducted over four days to obtain dynamic characteristics. The Enhanced Frequency Domain Decomposition technique is used to estimate natural frequencies, mode shapes and damping ratios of the Berke Arch Dam experimentally. Results showed that there were some differences between analytical and experimental natural frequencies of the dam. Therefore, an analytical model of Berke Arch Dam was calibrated to minimize these differences by changing material properties. Analytical results obtained from the calibrated model mainly conform to those of the experimental model.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12047Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/1077546310377912Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSevim, Bariş
dc.contributor.authorBayraktar, Alemdar
dc.contributor.authorAltunişik, Ahmet Can
dc.date.accessioned2026-10-22T10:19:37.674573783Z
dc.date.available2026-10-22T10:19:37.674573783Z
dc.date.issued2011
dc.description.abstractThis paper presents the finite element calibration of Berke Arch Dam by using Operational Modal Testing. Achievement of this purpose involves structural vibration characteristics of Berke Arch Dam using analytical and Operational Modal Analyses. Therefore, the study has two parts-analytical and experimental. In the analytical part of the study, the authors developed a 3D finite element model of Berke Arch Dam-reservoir-foundation system using ANSYS software, and analytically determined vibration characteristics such as natural frequencies and mode shapes. In the experimental part of the study, sensitive accelerometers were placed to several points of Berke Arch Dam, and ambient vibration tests were conducted over four days to obtain dynamic characteristics. The Enhanced Frequency Domain Decomposition technique is used to estimate natural frequencies, mode shapes and damping ratios of the Berke Arch Dam experimentally. Results showed that there were some differences between analytical and experimental natural frequencies of the dam. Therefore, an analytical model of Berke Arch Dam was calibrated to minimize these differences by changing material properties. Analytical results obtained from the calibrated model mainly conform to those of the experimental model.
dc.description.sponsorshipTUBITAK [106M038, 2006.112.001.1]
dc.description.sponsorshipKaradeniz Technical University [106M038, 2006.112.001.1]
dc.identifier.doi10.1177/1077546310377912
dc.identifier.eissn1741-2986
dc.identifier.endpage1079
dc.identifier.issn1741-2986
dc.identifier.issue7
dc.identifier.scopus2-s2.0-80051971237
dc.identifier.startpage1065
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12047
dc.identifier.volume17
dc.identifier.wosWOS:000291007600010
dc.language.isoen
dc.publisherSAGE PUBLICATIONS LTD
dc.relation.ispartofJVC/Journal of Vibration and Control
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectArch dams
dc.subjectFinite element model calibration
dc.subjectOperational modal testing
dc.subject.classificationAcoustics
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationMechanics
dc.subject.classificationEngineering
dc.subject.otherAccelerometers
dc.subject.otherArch dams
dc.subject.otherArches
dc.subject.otherCalibration
dc.subject.otherConcrete dams
dc.subject.otherDomain decomposition methods
dc.subject.otherMathematical models
dc.subject.otherModal analysis
dc.subject.otherNatural frequencies
dc.subject.otherReservoirs (water)
dc.subject.otherStructural dynamics
dc.subject.otherThree dimensional
dc.subject.otherUnderwater foundations
dc.subject.otherVibration analysis
dc.subject.other3D finite element model
dc.subject.otherAmbient vibration test
dc.subject.otherAnalytical model
dc.subject.otherAnalytical results
dc.subject.otherANSYS software
dc.subject.otherCalibrated model
dc.subject.otherDam-reservoir-foundation systems
dc.subject.otherDamping ratio
dc.subject.otherDynamic characteristics
dc.subject.otherExperimental models
dc.subject.otherFinite Element
dc.subject.otherFinite element models
dc.subject.otherFrequency domain decomposition
dc.subject.otherMaterial property
dc.subject.otherMode shapes
dc.subject.otherOperational modal
dc.subject.otherOperational modal analysis
dc.subject.otherOperational modal testing
dc.subject.otherStructural vibrations
dc.subject.otherVibration characteristics
dc.subject.otherFinite element method
dc.titleFinite element model calibration of berke arch dam using operational modal testing
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex44
rdl.citation.scopus53
rdl.citation.wos43
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)