A combined Monte Carlo, analytical, and experimental study of true coincidence summing correction factors for 152Eu

MakaleAçık Erişim

Özet

The radionuclide 152Eu presents a significant challenge in gamma-ray spectrometry due to its complex decay scheme and significant true coincidence summing (TCS) effects, especially in close-measurement geometries. This study presents a comprehensive investigation into TCS correction factors for the principal gamma-ray lines of 152Eu using tripartite methodology: a custom Monte Carlo (MC) simulation based on the EGS4 system, an established analytical method, and direct experimental measurements. The MC simulation explicitly models the complete decay process, including branching ratios, gamma emissions, internal conversion, and subsequent X-ray emissions for both decay branches (beta-minus to 152Gd and EC to 152Sm). Experimentally, correction factors were derived using a well-characterized point source measured at multiple distances with a coaxial HPGe detector. The analytical, method based on probabilistic analysis of the decay scheme, served as an examination. Results demonstrate that the analytical method underestimated the TCS correction factors, particularly for low-energy lines such as 121.78 keV, where it predicted a mere 0.78 % correction compared to 25.5 and 23.5 % from MC and experiment, respectively. This discrepancy is attributed to the analytical method's neglect of gamma-X ray coincidences and the internal conversion effects. In contrast, the MC simulation showed remarkable agreement with experimental results across all energies, validating its capability to accurately model the full complexity of TCS effects. The study concludes that while analytical methods offer rapid estimates, MC simulations, especially when experimentally validated, are essential for achieving metrological accuracy in the gamma-ray spectrometric analysis of complex radionuclides like 152Eu.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/10543Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇelik, Necati
dc.contributor.authorAli, Ahmed H.
dc.contributor.authorApaydin, Gokhan
dc.contributor.authorÇevik, Ugur
dc.contributor.authorAçikel, Selami
dc.date.accessioned2026-10-22T09:23:04.487060012Z
dc.date.available2026-10-22T09:23:04.487060012Z
dc.date.issued2026-03
dc.description.abstractThe radionuclide 152Eu presents a significant challenge in gamma-ray spectrometry due to its complex decay scheme and significant true coincidence summing (TCS) effects, especially in close-measurement geometries. This study presents a comprehensive investigation into TCS correction factors for the principal gamma-ray lines of 152Eu using tripartite methodology: a custom Monte Carlo (MC) simulation based on the EGS4 system, an established analytical method, and direct experimental measurements. The MC simulation explicitly models the complete decay process, including branching ratios, gamma emissions, internal conversion, and subsequent X-ray emissions for both decay branches (beta-minus to 152Gd and EC to 152Sm). Experimentally, correction factors were derived using a well-characterized point source measured at multiple distances with a coaxial HPGe detector. The analytical, method based on probabilistic analysis of the decay scheme, served as an examination. Results demonstrate that the analytical method underestimated the TCS correction factors, particularly for low-energy lines such as 121.78 keV, where it predicted a mere 0.78 % correction compared to 25.5 and 23.5 % from MC and experiment, respectively. This discrepancy is attributed to the analytical method's neglect of gamma-X ray coincidences and the internal conversion effects. In contrast, the MC simulation showed remarkable agreement with experimental results across all energies, validating its capability to accurately model the full complexity of TCS effects. The study concludes that while analytical methods offer rapid estimates, MC simulations, especially when experimentally validated, are essential for achieving metrological accuracy in the gamma-ray spectrometric analysis of complex radionuclides like 152Eu.
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [124F477]
dc.identifier.articlenumber113459
dc.identifier.doi10.1016/j.radphyschem.2025.113459
dc.identifier.eissn1879-0895
dc.identifier.issn0969-806X
dc.identifier.scopus2-s2.0-105021821118
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/10543
dc.identifier.volume240
dc.identifier.wosWOS:001621106300001
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofRADIATION PHYSICS AND CHEMISTRY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject152Eu decay
dc.subjectCoincidence summing correction
dc.subjectGamma-ray spectrometry
dc.subjectHPGe detector
dc.subjectMonte Carlo simulation
dc.subjectEGS4
dc.subject.classificationChemistry, Physical
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationPhysics, Atomic, Molecular & Chemical
dc.subject.classificationChemistry
dc.subject.classificationPhysics
dc.subject.otherGAMMA-RAY SPECTROMETRY
dc.titleA combined Monte Carlo, analytical, and experimental study of true coincidence summing correction factors for 152Eu
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex0
rdl.citation.scopus1
rdl.citation.wos1
rdl.oa.statusgreen
rdl.oa.statusclosed
rdl.oa.urlhttps://doi.org/10.2139/ssrn.5536915