Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleAçık Erişim2026Scopus SJRQ1
    A novel SSI-based optimization framework for non-traditional TMDI system under near- and far-fault ground motions

    Araz, Onur; Forcellini, Davide

    Previous studies on the optimal parameter selection of non-traditional tuned mass damper inerter (N-TMDI) system have predominantly adopted a fixed-base assumption. However, neglecting soil–structure interaction (SSI) in practical applications may lead to significant design inaccuracies and reduced control performance of the N-TMDI system. To overcome this limitation, a new design framework is proposed for the tuning of N-TMDI systems installed in primary structures subjected to ground motion by explicitly considering SSI effects. The novelty of the proposed approach consists of performing a hybrid GA-PSO optimization algorithm to study the efficiency of N-TMDI system under near- and far-field ground motions. This study investigates the influence of varying mass and inerter ratios on the system's dynamic response through frequency-domain analyses. The performance of the N-TMDI system is subsequently validated using real earthquake records, with a specific focus on the comparative effects of near-fault and far-fault ground motions under diverse soil conditions. The results demonstrate that the inerter mass ratio is the most dominant factor in enhancing seismic protection, significantly reducing structural displacement and acceleration compared to conventional TMD. Furthermore, the findings reveal that SSI and the distinct characteristics of ground motions significantly modify the system's control efficiency. This research confirms the robustness of the optimized N-TMDI design, providing a reliable and efficient strategy for seismic structural control under varied seismic scenarios.

    AtıfScopus1WoS1
    İncele
  • MakaleYalnız künye2026Scopus SJRQ1
    Effects of earthquake frequency content and isolation thickness on seismic behavior of a structure system resting on geotechnical seismic isolation layer

    Ozturk, Kasif Furkan; Cakir, Tufan; Araz, Onur

    Geotechnical seismic isolation (GSI) systems aim to partially dissipate the energy before it reaches the foundation of the structure system and are therefore regarded as an important alternative to structural seismic isolation systems. In addition, the use of petroleum-derived waste materials in the GSI systems fills a significant gap in the field of waste recovery. The present study investigates the changes in the dynamic responses of a 5-story building system with and without GSI, using a set of earthquakes classified according to their frequency content. For this purpose, parametric analyses were performed using analytical methods, considering three different earthquake frequency contents and six different GSI thicknesses. Furthermore, an approach for selecting the GSI thickness was suggested. The results generally show that, for structures founded on both natural soil (NS) and GSI systems, the earthquakes with low frequency content produce responses greater than the average responses calculated for all the investigated earthquakes. Although increasing the GSI thickness has a significant effect on attenuating structural responses, increasing this thickness beyond 3 m does not lead to a relatively significant reduction in the dynamic responses of the investigated structural system. Therefore, considering the structural system, NS, rubber-soil mixtures and earthquakes examined in this study, selecting a GSI thickness in the range of 2–3 m (inclusive) may be regarded as a practical approach for mitigating the dynamic responses of the structure since further increments in thickness beyond this range provide only progressively limited improvements in structural responses. Consequently, this research may provide meaningful data for the development of vibration control strategies to improve seismic resilience of structures, and the results are expected to be useful for better understanding of the GSI applications.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
  • MakaleYalnız künye2025Scopus SJRQ1
    Performance evaluation and optimization of nontraditional inerter-based tuned mass damper for seismic control of multi-story buildings considering SSI effects

    Araz, Onur

    This article presents the optimum design and performance evaluation of a control system that can be an alternative to traditional inerter-based tuned mass damper (TMDI) used in reducing vibrations in a multi-story building under earthquake effects considering soil-structure interaction (SSI). The optimum design of this system, known as NIDVA-C4 in the literature, has been carried out previously considering the randomly excited undamped main system. The key novelty of this work is to demonstrate the applicability of this system to suppress earthquake-induced vibrations in a multi-story building and to deliver more accurate and reliable results by integrating SSI effects into the optimization framework. Due to the difference in location and connection, this system is called N-TMDI in this paper. A case study from the literature featuring a ten-story building is used to implement the design process, assess performance, and conduct comparisons. The optimum parameters of the N-TMDI are obtained using the hybrid PSO-SA algorithm in the frequency domain. Validation using real earthquake records under varying soil conditions confirms the reliability of the proposed optimization framework. The coupled dynamic equations of motion for the structure - N-TMDI, accounting for SSI effects, are formulated and solved in the time domain using the Newmark-β method. An extensive parametric analysis is conducted to evaluate the effectiveness of the N-TMDI in improving the seismic response of the buildings. The results consistently demonstrate the effectiveness of the proposed protection strategy across a wide range of parametric configurations, highlighting its potential as a viable seismic mitigation strategy for a multi-story building.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    AtıfScopus26WoS23OpenAlex19
    İncele
  • MakaleAçık Erişim2025Scopus SJRQ1
    Effect of basic parameters defining principal soil-structure interaction on seismic control of structures equipped with optimum tuned mass damper

    Araz, Onur

    One of the most effective systems for reducing dynamic responses of the structures subjected to earthquake excitations is tuned mass dampers (TMDs). In the traditional design theory of TMDs, the structures are assumed to be rigidly connected to the ground. Using this approach, known as the fixed foundation approach, may lead to deterioration of the performance of the TMD in cases where soil-structure interaction (SSI) is significant. Therefore, it is crucial to consider the SSI effects to obtain the optimum parameters of the TMDs. Unlike previous studies, two key parameters (i.e., structure-to-soil stiffness ratio and aspect ratio of the structure) are considered, which define the principal SSI effects on the effectiveness of TMD. For the aspect ratio of the structure, three different values (i.e., λ = 1, 2, and 4) are considered, these values correspond to the squat, ordinary, and slender structures representing traditional buildings, respectively. Four different values (i.e., a0 = 0, 0.5, 1, and 2) are also considered for the structure-soil stiffness ratio. This ratio being equal to 0 corresponds to the fixed foundation approach. This also demonstrates that the structure is constructed on hard rock. The optimum parameters of the TMD are obtained using the Jaya algorithm (JA). The proposed methodology is applied to three different buildings (i.e., 3-story, 6-story, and 12-story), and the optimum parameters of the TMD are verified using a total of 72 ground motions corresponding to NEHRP site classes C, D, and E. Numerical results show that the effectiveness of TMD is significantly affected by the basic parameters that define the principal SSI. In addition, the efficiency of the TMD is significantly related to the characteristics of the ground motions. It has been observed that TMD does not perform adequately in reducing vibrations in low-rise buildings (i.e., λ = 1) constructed on low-stiffness soils (i.e., a0 = 2).

    AtıfScopus42WoS38OpenAlex34
    İncele
  • MakaleAçık Erişim2024Scopus SJRQ1
    Performance of differently arranged double-tuned mass dampers for structural seismic response control including soil-structure interaction

    Araz, Onur; Elias, Said

    Reducing vibrations occurring in structures under environmental loads makes a significant contribution to the development of structural safety. Tuned mass dampers (TMD) are one of the systems commonly used to control structural vibrations. Since TMD is adjusted according to the dominant frequency of the structure, factors that may cause changes in the frequency of the structure can significantly reduce the effectiveness of TMD. One of the main factors that can cause changes in the frequency values of the structure is the interaction between the structure and the soil. To overcome this situation, it is recommended to apply control systems consisting of multiple TMDs (MTMD) to the main structure instead of a single TMD. MTMD systems are arranged in two different types, serial and parallel. In this paper, a methodology that considers the structure-soil interaction (SSI) is presented for the optimum design of control systems with different configurations placed on a main structure under the influence of ground motion. To research the SSI effects, the TMDs-structure coupled system is supported by rocking and swaying springs and the corresponding dashpots, and then the equations of motions of the structural system are derived. In the optimization process based on particle swarm optimization in the frequency domain, different soil types, configuration types, and mass ratios are considered. The efficiency of optimum TMDs arranged in series and parallel is also evaluated using near and far fault ground motions in the time domain. Numerical results show that if structures are constructed on soils with low shear wave velocities, ignoring SSI can significantly change the design parameters and effectiveness of the control system.

    AtıfScopus34WoS30OpenAlex32
    İncele