Performance evaluation and optimization of nontraditional inerter-based tuned mass damper for seismic control of multi-story buildings considering SSI effects

MakaleYalnız künye
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

This article presents the optimum design and performance evaluation of a control system that can be an alternative to traditional inerter-based tuned mass damper (TMDI) used in reducing vibrations in a multi-story building under earthquake effects considering soil-structure interaction (SSI). The optimum design of this system, known as NIDVA-C4 in the literature, has been carried out previously considering the randomly excited undamped main system. The key novelty of this work is to demonstrate the applicability of this system to suppress earthquake-induced vibrations in a multi-story building and to deliver more accurate and reliable results by integrating SSI effects into the optimization framework. Due to the difference in location and connection, this system is called N-TMDI in this paper. A case study from the literature featuring a ten-story building is used to implement the design process, assess performance, and conduct comparisons. The optimum parameters of the N-TMDI are obtained using the hybrid PSO-SA algorithm in the frequency domain. Validation using real earthquake records under varying soil conditions confirms the reliability of the proposed optimization framework. The coupled dynamic equations of motion for the structure - N-TMDI, accounting for SSI effects, are formulated and solved in the time domain using the Newmark-β method. An extensive parametric analysis is conducted to evaluate the effectiveness of the N-TMDI in improving the seismic response of the buildings. The results consistently demonstrate the effectiveness of the proposed protection strategy across a wide range of parametric configurations, highlighting its potential as a viable seismic mitigation strategy for a multi-story building.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14264Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAraz, Onur
dc.date.accessioned2026-10-22T10:22:28.648460029Z
dc.date.available2026-10-22T10:22:28.648460029Z
dc.date.issued2025
dc.description.abstractThis article presents the optimum design and performance evaluation of a control system that can be an alternative to traditional inerter-based tuned mass damper (TMDI) used in reducing vibrations in a multi-story building under earthquake effects considering soil-structure interaction (SSI). The optimum design of this system, known as NIDVA-C4 in the literature, has been carried out previously considering the randomly excited undamped main system. The key novelty of this work is to demonstrate the applicability of this system to suppress earthquake-induced vibrations in a multi-story building and to deliver more accurate and reliable results by integrating SSI effects into the optimization framework. Due to the difference in location and connection, this system is called N-TMDI in this paper. A case study from the literature featuring a ten-story building is used to implement the design process, assess performance, and conduct comparisons. The optimum parameters of the N-TMDI are obtained using the hybrid PSO-SA algorithm in the frequency domain. Validation using real earthquake records under varying soil conditions confirms the reliability of the proposed optimization framework. The coupled dynamic equations of motion for the structure - N-TMDI, accounting for SSI effects, are formulated and solved in the time domain using the Newmark-β method. An extensive parametric analysis is conducted to evaluate the effectiveness of the N-TMDI in improving the seismic response of the buildings. The results consistently demonstrate the effectiveness of the proposed protection strategy across a wide range of parametric configurations, highlighting its potential as a viable seismic mitigation strategy for a multi-story building.
dc.identifier.articlenumber110350
dc.identifier.doi10.1016/j.istruc.2025.110350
dc.identifier.issn2352-0124
dc.identifier.scopus2-s2.0-105018100882
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14264
dc.identifier.volume81
dc.identifier.wosWOS:001590004000003
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofStructures
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectInerter
dc.subjectOptimal design
dc.subjectSeismic control
dc.subjectSoil-structure interaction
dc.subjectTuned mass damper
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherArchitectural design
dc.subject.otherEarthquake effects
dc.subject.otherFrequency domain analysis
dc.subject.otherSeismic design
dc.subject.otherSeismic response
dc.subject.otherSoils
dc.subject.otherStructural optimization
dc.subject.otherTime domain analysis
dc.subject.otherVibration control
dc.subject.otherVibrations (mechanical)
dc.subject.otherInerter
dc.subject.otherMultistory building
dc.subject.otherOptimal design
dc.subject.otherOptimization framework
dc.subject.otherOptimum designs
dc.subject.otherPerformances evaluation
dc.subject.otherSeismic control
dc.subject.otherSoil-structure interaction
dc.subject.otherSoil-Structure Interaction effects
dc.subject.otherTuned mass dampers
dc.subject.otherSoil structure interactions
dc.titlePerformance evaluation and optimization of nontraditional inerter-based tuned mass damper for seismic control of multi-story buildings considering SSI effects
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex19
rdl.citation.scopus26
rdl.citation.wos23
rdl.oa.statusclosed
rdl.sdgSDG11
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)