- MakaleYalnız künye2020Scopus SJRQ3PUC program: The pulse pile up correction for x-ray and gamma ray spectrometry
Karabıdak, S.M.; Kaya, S.
Pile up and dead time are two important corrections in the analysis of X-ray and gamma ray spectra. The most important of these is pile up correction because these peaks do not really exist in the spectra; they only seem to exist. For this reason, these peaks affect both the qualitative and quantitative accuracy of the analysis. In addition, the pile up pulses forming the pile up peaks increase the background count in the spectrum. Companies that produce X-ray or gamma ray detector systems design pile up reject circuits and integrate them into detector systems to prevent these pulses. These circuits have time limitations because they are made up of electronic devices. For this reason, the pile up problem cannot be solved completely in these circuits. Therefore, mathematical models based on a statistical approach are needed. Such a model was developed in this study. A computer program based on this model was developed. This developed program has been applied to X-ray and gamma ray spectra. It has been shown that this model provides about 2% correction in the main peak regions and significantly reduces background counts.
AtıfScopus3WoS2OpenAlex3İncele
- MakaleYalnız künye2013Scopus SJRQ2Decaying source model: Alternative approach to determination of true counting rates at X and gamma ray counting systems
Karabidak, S.M.; Cevik, U.
The counting systems consisting of electronic devices are used for detection of radiation due to X or gamma rays. The dead time of the counting system is based on time limitations of these electronic devices. The dead time causes counting losses. Determination of counting rate losses in quantitative and qualitative analysis become a vital step for correction of analysis. Therefore, compensating for counting rate losses is of great importance. These counting rate losses are due to piled up reject time, paralyzable or non-paralyzable system dead time or a combination of these mechanisms. Paralyzable and non-paralyzable models are well-known and frequently used for correction of counting rate losses dependent on the system dead time. However, these two models do not provide enough correction at medium and high counting rates. Therefore, the new models for corrections of counting rate losses are needed. For this reason, both an alternative approach is proposed and a simulation program is coded for counting rate losses in this study. A good agreement is obtained between theoretical model and simulation program.
AtıfScopus7WoS6OpenAlex9İncele
- MakaleYalnız künye2011Scopus SJRQ1Determination of proper peaking time for Ultra-LEGe detector
Karabidak, S. M.; Kaya, S.; Çevik, U.; Çelik, A.
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the proper peaking time for particular detector systems is important. The characteristic X-rays emitted from pure some elements were detected by using an Ultra-LEGe detector connecting a Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by an HM 203-7 oscilloscope connecting amplifier. The proper peaking time for Ultra-LEGe is determined as 3.84 mu s. (C) 2011 Elsevier Ltd. All rights reserved.
AtıfWoS6OpenAlex9İncele