Determination of proper peaking time for Ultra-LEGe detector

MakaleYalnız künye

Özet

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the proper peaking time for particular detector systems is important. The characteristic X-rays emitted from pure some elements were detected by using an Ultra-LEGe detector connecting a Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by an HM 203-7 oscilloscope connecting amplifier. The proper peaking time for Ultra-LEGe is determined as 3.84 mu s. (C) 2011 Elsevier Ltd. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15876Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKarabidak, S. M.
dc.contributor.authorKaya, S.
dc.contributor.authorÇevik, U.
dc.contributor.authorÇelik, A.
dc.date.accessioned2026-10-22T10:26:10.536829374Z
dc.date.available2026-10-22T10:26:10.536829374Z
dc.date.issued2011-04
dc.description.abstractReducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the proper peaking time for particular detector systems is important. The characteristic X-rays emitted from pure some elements were detected by using an Ultra-LEGe detector connecting a Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by an HM 203-7 oscilloscope connecting amplifier. The proper peaking time for Ultra-LEGe is determined as 3.84 mu s. (C) 2011 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.radmeas.2011.01.023
dc.identifier.endpage450
dc.identifier.issn1350-4487
dc.identifier.issue4
dc.identifier.startpage446
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15876
dc.identifier.volume46
dc.identifier.wosWOS:000290357500013
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofRADIATION MEASUREMENTS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectPile-up
dc.subjectPeaking time
dc.subjectResolving time
dc.subjectDead time
dc.subjectUltra-LEGe detector
dc.subject.classificationNuclear Science & Technology
dc.titleDetermination of proper peaking time for Ultra-LEGe detector
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex9
rdl.citation.wos6
rdl.oa.statusclosed
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)