Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleYalnız künye2022
    Detection of 2D and 3D Video Transitions Based on EEG Power

    Manshouri, Negin; Melek, Mesut; Kaylkcloglu, Temel

    Despite the long and extensive history of 3D technology, it has recently attracted the attention of researchers. This technology has become the center of interest of young people because of the real feelings and sensations it creates. People see their environment as 3D because of their eye structure. In this study, it is hypothesized that people lose their perception of depth during sleepy moments and that there is a sudden transition from 3D vision to 2D vision. Regarding these transitions, the EEG signal analysis method was used for deep and comprehensive analysis of 2D and 3D brain signals. In this study, a single-stream anaglyph video of random 2D and 3D segments was prepared. After watching this single video, the obtained EEG recordings were considered for two different analyses: the part involving the critical transition (transition state) and the state analysis of only the 2D versus 3D or 3D versus 2D parts (steady state). The main objective of this study is to see the behavioral changes of brain signals in 2D and 3D transitions. To clarify the impacts of the human brain's power spectral density (PSD) in 2D-to-3D (2D_3D) and 3D-to-2D (3D_2D) transitions of anaglyph video, nine visual healthy individuals were prepared for testing in this pioneering study. Spectrogram graphs based on short time Fourier transform (STFT) were considered to evaluate the power spectrum analysis in each EEG channel of transition or steady state. Thus, in 2D and 3D transition scenarios, important channels representing EEG frequency bands and brain lobes will be identified. To classify the 2D and 3D transitions, the dominant bands and time intervals representing the maximum difference of PSD were selected. Afterward, effective features were selected by applying statistical methods such as standard deviation, maximum (max) and Hjorth parameters to epochs indicating transition intervals. Ultimately, k-nearest neighbors, support vector machine and linear discriminant analysis (LDA) algorithms were applied to classify 2D_3D and 3D_2D transitions. The frontal, temporal and partially parietal lobes show 2D_3D and 3D_2D transitions with a good classification success rate. Overall, it was found that Hjorth parameters and LDA algorithms have 71.11% and 77.78% classification success rates for transition and steady state, respectively.

  • BildiriAçık Erişim2021
    Automatic Sleep Scoring System Based On Autoregressive Model

    Melek, Mesut

    Electroencephalography (EEG) signals recorded during sleep are divided into 30-second segments and analyzed by experts and classified into sleep stages, and in this way, diagnosis and treatment of diseases are made. Computer-assisted sleep scoring systems can effectively reduce the burden of experts by classifying sleep stages. In this study, after preprocessing of the EEG signals, four features were obtained for each EEG band (20 features in total) with the autoregressive model and then classified with three different classifiers common in machine learning. The proposed method was tested on the data set called ISRUC sleep (Subgroup 3, ISRUC3) and the results were compared with the results of other studies. The results show that the proposed method is more successful than other existing methods, despite the use of fewer features.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
  • MakaleYayıncıda açık erişim2021
    An automatic EEG-based sleep staging system with introducing NAoSP and NAoGP as new metrics for sleep staging systems

    Melek, Mesut; Manshouri, Negin; Kayikcioglu, Temel

    Different biological signals are recorded in sleep labs during sleep for the diagnosis and treatment of human sleep problems. Classification of sleep stages with electroencephalography (EEG) is preferred to other biological signals due to its advantages such as providing clinical information, cost-effectiveness, comfort, and ease of use. The evaluation of EEG signals taken during sleep by clinicians is a tiring, time-consuming, and error-prone method. Therefore, it is clinically mandatory to determine sleep stages by using software-supported systems. Like all classification problems, the accuracy rate is used to compare the performance of studies in this domain, but this metric can be accurate when the number of observations is equal in classes. However, since there is not an equal number of observations in sleep stages, this metric is insufficient in the evaluation of such systems. For this purpose, in recent years, Cohen’s kappa coefficient and even the sensitivity of NREM1 have been used for comparing the performance of these systems. Still, none of them examine the system from all dimensions. Therefore, in this study, two new metrics based on the polygon area metric, called the normalized area of sensitivity polygon and normalized area of the general polygon, are proposed for the performance evaluation of sleep staging systems. In addition, a new sleep staging system is introduced using the applications offered by the MATLAB program. The existing systems discussed in the literature were examined with the proposed metrics, and the best systems were compared with the proposed sleep staging system. According to the results, the proposed system excels in comparison with the most advanced machine learning methods. The single-channel method introduced based on the proposed metrics can be used for robust and reliable sleep stage classification from all dimensions required for real-time applications.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
  • MakaleAçık Erişim2020
    Low-cost brain-computer interface using the emotiv epoc headset based on rotating vanes

    Melek, Mesut; Manshouri, Negin; Kayikcioglu, Temel

    In the brain-computer interface system (BCI), electroencephalography (EEG) signals are converted into digital signals and analyzed, allowing direct communication between humans and the electronic devices around them. The convenience of the user and the speed of communication with the surrounding devices are the most important challenges of BCI systems. The Emotiv Epoc headset minimizes the discomfort of the user thanks to its wet electrodes and easy handling. In the continuation of our previous works, in this paper, we developed our BCI system based on the gaze at the rotating vanes using the inexpensive Emotiv Epoc headset. In addition to user comfort, our design has an acceptable mean accuracy rate (ACC) and mean information transfer rate (ITR) compared to similar systems.

  • MakaleYalnız künye2020
    An EEG-based stereoscopic research of the PSD differences in pre and post 2D&3D movies watching

    Manshouri, Negin; Maleki, Masoud; Kayikcioglu, Temel

    Despite knowing the reality of three-dimensional (3D) technology in the form of eye fatigue, this technology continues to be retained by people (especially the young community). To check the influences of the human brain's power spectrum density (PSD) pre and post a 2D and 3D movie watching, a five-member test group was arranged. In this study, electroencephalogram (EEG) was used as a neuroimaging method. EEG recordings of five individuals were taken both before and after watching 2D and 3D movies. The main framework of this study was to analyze the effects of power spectrum density (PSD) of the human brain by testing all EEG frequency bands before and after 2D and 3D movie watching, also to determine effective brain lobes, and consequently, EEG channels. After 2D/3D EEG recording, this record was divided into three stages for analysis. These stages consisted of Relax, Watching, and Rest. This benchmarking analysis included I) before and after watching the 2D movie (R2b and R2a), II) before and after watching the 3D movie (R3b and R3a), and III) after watching the 2D/3D movie (R2a and R3a). In the Relax and Rest stages, the 2D/3D EEG power differences in all channels of brain regions for the five EEG bands, including delta (δ), theta (θ), alpha (α), beta (β), and gamma (γ), were analyzed and compared. The PSD based on short-time Fourier transform (STFT) was used to select the dominant bands in this study. Feature extraction was performed on the preprocessed EEG signals using STFT and discrete wavelet transform (DWT). In the 2D analysis, δ, θ, α, and β acted as dominant bands, in 3D, δ, θ, and α were dominant bands, and in 2D/3D, δ and α were selected as meaningful and dominant bands. Partial least-squares regression (PLSR) and support vector machine (SVM) classification algorithms were considered in order to classify the obtained R2a and R3a EEG signals. After the dominant band selection, the correct choice of effective channel combinations in these bands resulted in the percentage of high success of classifiers for Stage III. Taking into account the optimum number of channels, the best percentage of classification accuracy for the average of PLSR and SVM classification results by considering the best channels of SVM and DWT feature extraction method is 91.83% and 80.73% respectively.

  • BildiriYalnız künye2018
    Detecting Cardiac Arrhythmia by Using Time Differences of Double Wavelength PPG Peaks

    Yildirim, Omer; Kayikçioglu, Temel

    Nowadays, photopletismogram (PPG) signals are used in respiration and blood pressure measurement, monitoring of the sleep pattern and also detecting of mental disorders, mainly blood oxygen saturation and heartrate measurement. The reason of the use of PPG signals instead of signals such as electroencephalogram (EEG) or electrocardiogram (ECG) is easy to obtain and real-time monitoring of these data, as well as being easily used by people in daily life and easily integrated into wearable technologies. In this study, detecting of cardiac arrhythmia was made successfully by using double wavelength PPG signals instead of ECG signals