Sürdürülebilir Kalkınma Amaçları

  • MakaleAçık Erişim2023
    Assessment of photovoltaic module temperature estimation for four years with four different software; [Dört yıllık fotovoltaik modül sıcaklık tahmininin dört farklı yazılımla değerlendirilmesi]

    Tolgay, Doga; Yakut, Muhammet Samet; Ozden, Talat; Akinoglu, Bulent G.

    The software used today, on the estimation of module temperature of photovoltaic systems, seem very important to be analyzed. These estimates are crucial in future techno-economic and environmentally friendly analyses of the systems to reach better achievements for future generations. This is very important to reach lifetime analyses of long-term feasibility to find out payback time and the levelized cost of energy. The present work is based on this issue, to test the module temperature estimation formulas used by four commonly used software models, and to determine the most suitable software for temperature analyses of five different photovoltaic modules in Middle Anatolia. Outdoor truthful long-term testing is the main realistic approach to reach fundamental contemplations. After an introductory basic knowledge, the main materials and methods are discussed to enlighten the analysis. The main methodology is given and further prospects are enlightened. Four well-known software are analyzed using four years of outdoor testing of five different photovoltaic modules. Measured ambient temperature and solar irradiance are used in the categorization of the software estimation performances. PV*SOL appears to be superior at low irradiance and ambient temperature, whereas Helioscope appears to be superior overall.

  • MakaleAçık Erişim2020
    AN EXTENDED ANALYSIS OF THE MODELS TO ESTIMATE PHOTOVOLTAIC MODULE TEMPERATURE

    Ozden, Talat; Tolgay, Doga; Yakut, M. Samet; Akinoglu, Bulent G.

    To estimate the performance of the photovoltaic power systems is the key issue in their techno-economic feasibility analysis. Performances, on the other hand, strongly depends on the module temperatures of the photovoltaic systems. In this study, we evaluated the performance of ten different module temperature estimation models using the measured outdoor data of five different modules. The modules are installed at the rooftop of a building located at Central Anatolia where the climate is cold and semi-arid. The results showed that the models having smaller number of parameters perform better than the others. We concluded that such analysis should be carried out at different ambient conditions so that the best performing models for the site can be obtained. Another outcome of the study is that the seasonal evaluation of the performance of the models should be carried out.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi
  • BildiriAçık Erişim2018
    Daily and monthly module temperature variation for 9 different modules

    Özden, Talat; Tolgay, Doga; Akinoglu, Bulent G.

    One of the main parameter affecting the efficiency of PV modules is the module temperature. In this respect, outdoor testing of modules is very important to determine the temperature dependent performances and degradation rates. In this work, we analyzed the module temperatures of 9 different modules tested in the outdoor testing facility of METU-GUNAM, Ankara (latitude ∼40°N, in Central Anatolia and the climate is dry continental). The tested module types are two CIS (identical), one μc-Si/a-Si, one Poly-Si, three Mono-Si (two identical), one HIT and one bifacial. The module temperatures can reach up to 76°C while the ambient is around 39 °C during summer days. Monthly average module temperatures can reach up to 33.7°C (CIS) while the monthly average ambient is at 26.0°C and drops down to 1 °C while average ambient temperature is about the same as average module temperature. The results showed that the monthly averages of module temperatures differences are maximum during summer (∼3.5°C) and minimum during winter (1.1°C). It is interesting that the two CIS modules have the highest monthly average module temperature and although they are supposed to be identical their temperatures differ significantly. Bifacial and HIT module temperatures are lower than the Mono-Si modules. One of the two identical Mono-Si modules was not cleaned and its module temperature is always lower than the one that was cleaned periodically, as expected. In this work, we also present the results and discussions on the spatial variations of measured module temperatures of PV panels.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi