Daily and monthly module temperature variation for 9 different modules

BildiriAçık Erişim
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

One of the main parameter affecting the efficiency of PV modules is the module temperature. In this respect, outdoor testing of modules is very important to determine the temperature dependent performances and degradation rates. In this work, we analyzed the module temperatures of 9 different modules tested in the outdoor testing facility of METU-GUNAM, Ankara (latitude ∼40°N, in Central Anatolia and the climate is dry continental). The tested module types are two CIS (identical), one μc-Si/a-Si, one Poly-Si, three Mono-Si (two identical), one HIT and one bifacial. The module temperatures can reach up to 76°C while the ambient is around 39 °C during summer days. Monthly average module temperatures can reach up to 33.7°C (CIS) while the monthly average ambient is at 26.0°C and drops down to 1 °C while average ambient temperature is about the same as average module temperature. The results showed that the monthly averages of module temperatures differences are maximum during summer (∼3.5°C) and minimum during winter (1.1°C). It is interesting that the two CIS modules have the highest monthly average module temperature and although they are supposed to be identical their temperatures differ significantly. Bifacial and HIT module temperatures are lower than the Mono-Si modules. One of the two identical Mono-Si modules was not cleaned and its module temperature is always lower than the one that was cleaned periodically, as expected. In this work, we also present the results and discussions on the spatial variations of measured module temperatures of PV panels.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15103Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/pvcon.2018.8523878Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
WoS
0
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÖzden, Talat
dc.contributor.authorTolgay, Doga
dc.contributor.authorAkinoglu, Bulent G.
dc.contributor.otherIEEE
dc.date.accessioned2026-10-22T10:23:35.511917836Z
dc.date.available2026-10-22T10:23:35.511917836Z
dc.date.issued2018
dc.description.abstractOne of the main parameter affecting the efficiency of PV modules is the module temperature. In this respect, outdoor testing of modules is very important to determine the temperature dependent performances and degradation rates. In this work, we analyzed the module temperatures of 9 different modules tested in the outdoor testing facility of METU-GUNAM, Ankara (latitude ∼40°N, in Central Anatolia and the climate is dry continental). The tested module types are two CIS (identical), one μc-Si/a-Si, one Poly-Si, three Mono-Si (two identical), one HIT and one bifacial. The module temperatures can reach up to 76°C while the ambient is around 39 °C during summer days. Monthly average module temperatures can reach up to 33.7°C (CIS) while the monthly average ambient is at 26.0°C and drops down to 1 °C while average ambient temperature is about the same as average module temperature. The results showed that the monthly averages of module temperatures differences are maximum during summer (∼3.5°C) and minimum during winter (1.1°C). It is interesting that the two CIS modules have the highest monthly average module temperature and although they are supposed to be identical their temperatures differ significantly. Bifacial and HIT module temperatures are lower than the Mono-Si modules. One of the two identical Mono-Si modules was not cleaned and its module temperature is always lower than the one that was cleaned periodically, as expected. In this work, we also present the results and discussions on the spatial variations of measured module temperatures of PV panels.
dc.identifier.articlenumber8523878
dc.identifier.doi10.1109/pvcon.2018.8523878
dc.identifier.isbn978-153867538-0
dc.identifier.scopus2-s2.0-85058242881
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15103
dc.identifier.wosWOS:000519584300002
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.conference2018 International Conference on Photovoltaic Science and Technologies, PVCon 2018
dc.relation.ispartofPVCon 2018 - International Conference on Photovoltaic Science and Technologies
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectModule temperature
dc.subjectPhotovoltaic performance analyses
dc.subjectPV modules
dc.subject.classificationGreen & Sustainable Science & Technology
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationScience & Technology - Other Topics
dc.subject.classificationEngineering
dc.subject.otherDegradation
dc.subject.otherMonocrystalline silicon
dc.subject.otherPhotovoltaic cells
dc.subject.otherTemperature
dc.subject.otherCentral anatolia
dc.subject.otherDegradation rate
dc.subject.otherMain parameters
dc.subject.otherModule temperature
dc.subject.otherPhotovoltaic performance
dc.subject.otherPV modules
dc.subject.otherSpatial variations
dc.subject.otherTemperature dependent
dc.subject.otherSilicon compounds
dc.titleDaily and monthly module temperature variation for 9 different modules
dc.typeConference Object
rdl.citation.openalex6
rdl.citation.scopus6
rdl.citation.wos0
rdl.conference.date4 July 2018 through 6 July 2018
rdl.conference.placeAnkara
rdl.oa.statusgreen
rdl.oa.statusclosed
rdl.oa.urlhttps://hdl.handle.net/11511/47573
rdl.sdgSDG07
rdl.sdgSDG13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexConference Proceedings Citation Index - Science (CPCI-S)