    Non-Invasive Monitoring of Ethanol and Methanol Levels in Grape-Derived Pisco Distillate by Vibrational Spectroscopy

    Menevseoglu, Ahmed; Aykas, Didem P.; Hatta-Sakoda, Beatriz; Toledo-Herrera, Victor Hugo; Rodriguez-Saona, Luis E.

    Handheld Raman and portable FT-IR spectroscopy devices were evaluated for fast and non-invasive determination of methanol and ethanol levels in Peruvian Pisco. Commercial Peruvian Pisco (n = 171) samples were kindly provided by the UNALM Alliance for Research in Alcohol and its Derivatives (Lima, Peru) and supplemented by purchases at grocery and online stores. Pisco spectra were collected on handheld Raman spectrometers equipped with either a 1064 nm or a 785 nm excitation laser and a portable infrared unit operating in transmission mode. The alcohol levels were determined by GC-MS. Calibration models used partial least-squares regression (PLSR) to develop prediction algorithms. GC-MS data revealed that 10% of Pisco samples had ethanol levels lower than 38%, indicating possible water dilution. Methanol levels ranged from 10 to 130 mg/100 mL, well below the maximum levels allowed for fruit brandies. Handheld Raman equipped with a 1064 nm excitation laser gave the best results for determining ethanol (SEP = 1.2%; RPre = 0.95) and methanol (SEP = 1.8 mg/100 mL; RPre = 0.93). Randomly selected Pisco samples were spiked with methanol (75 to 2800 mg/100 mL), and their Raman spectra were collected through their genuine commercial bottles. The prediction models gave an excellent performance (SEP = 98 mg/100 mL; RPre = 0.97), allowing for the non-destructive and non-contact determination of methanol and ethanol concentrations without opening the bottles.

    AtıfScopus19WoS17OpenAlex21
    ScopusWeb of SciencePubMedİncele
  • MakaleAçık Erişim2020Scopus SJRQ2
    In situ monitoring of sugar content in breakfast cereals using a novel ft-nir spectrometer

    Aykas, Didem Peren; Ball, Christopher; Menevseoglu, Ahmed; Rodriguez-Saona, Luis E.

    This research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis.

    • SDG 2 · Açlığa Son
    AtıfScopus15WoS14OpenAlex14
    ScopusWeb of Scienceİncele