In situ monitoring of sugar content in breakfast cereals using a novel ft-nir spectrometer
Özet
This research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Aykas, Didem Peren | |
| dc.contributor.author | Ball, Christopher | |
| dc.contributor.author | Menevseoglu, Ahmed | |
| dc.contributor.author | Rodriguez-Saona, Luis E. | |
| dc.date.accessioned | 2026-10-22T10:23:13.060691721Z | |
| dc.date.available | 2026-10-22T10:23:13.060691721Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | This research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis. | |
| dc.description.sponsorship | CDME | |
| dc.description.sponsorship | Doug Mooney | |
| dc.description.sponsorship | Ohio State University Center for Design and Manufacturing Excellence | |
| dc.description.sponsorship | Wyandot Inc. | |
| dc.identifier.articlenumber | 8774 | |
| dc.identifier.doi | 10.3390/app10248774 | |
| dc.identifier.eissn | 2076-3417 | |
| dc.identifier.issn | 2076-3417 | |
| dc.identifier.issue | 24 | |
| dc.identifier.scopus | 2-s2.0-85104481366 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/14841 | |
| dc.identifier.volume | 10 | |
| dc.identifier.wos | WOS:000602960800001 | |
| dc.language.iso | en | |
| dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | |
| dc.relation.ispartof | Applied Sciences (Switzerland) | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Breakfast cereal | |
| dc.subject | FT-NIR | |
| dc.subject | Handheld sensor | |
| dc.subject | Nutrition facts label | |
| dc.subject | PLSR | |
| dc.subject | Sugar content | |
| dc.subject.classification | Chemistry, Multidisciplinary | |
| dc.subject.classification | Engineering, Multidisciplinary | |
| dc.subject.classification | Materials Science, Multidisciplinary | |
| dc.subject.classification | Physics, Applied | |
| dc.subject.classification | Chemistry | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Materials Science | |
| dc.subject.classification | Physics | |
| dc.subject.other | SOLUBLE SOLIDS CONTENT | |
| dc.subject.other | RAPID-DETERMINATION | |
| dc.subject.other | NUTRITIONAL QUALITY | |
| dc.subject.other | DIETARY FIBER | |
| dc.subject.other | SUCROSE | |
| dc.subject.other | SPECTROSCOPY | |
| dc.subject.other | PRODUCTS | |
| dc.subject.other | FORMULAS | |
| dc.title | In situ monitoring of sugar content in breakfast cereals using a novel ft-nir spectrometer | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 14 | |
| rdl.citation.scopus | 15 | |
| rdl.citation.wos | 14 | |
| rdl.oa.status | gold | |
| rdl.oa.url | https://www.mdpi.com/2076-3417/10/24/8774/pdf?version=1607421824 | |
| rdl.sdg | SDG02 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |

