Safety and effectiveness of 5-mm and 10-mm electrothermal bipolar vessel sealers (LigaSure) in laparoscopic resections for sigmoid colon and rectal cancers

MakaleYalnız künye
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Background: LigaSure™ (Covidien, Mansfield, MA) has been used in cases undergoing laparoscopic colon and rectal resections. This study aims to analyze the efficacy and safety of the 5-mm and 10-mm devices. Subjects and Methods: Patients who received a laparoscopic or hand-assisted laparoscopic operation for a tumor located in the sigmoid colon or rectum since 2006 were abstracted from a prospectively designed database, and findings were analyzed in two groups based on size of the device used during the procedure. The videotapes of the procedures were watched, and operation reports were read to obtain further information on specific intra- and postoperative complications. Demographics, tumor and operation-related information, and postoperative data were compared. Results: Among 215 (128 [59.5%] males; median age, 59.5±13.8 years) patients, data obtained from the 5-mm (n=32) and 10-mm (n=183) groups were identical regarding demographics and data related to tumor (localization and stage) and operation (number of harvested lymph nodes, conversion rates, operation time, intraoperative bleeding, transfusion requirement, reoperation rates, complications, 30-day mortality, and length of hospital stay). However, more patients underwent an anterior resection in the 10-mm group than in the 5-mm group (31.7% versus 15.6%, P<.05). Further analyses found device-related bleeding in 8 (3.7%) cases (2 [6.3%] versus 6 [3.3%] in the 5-mm versus 10-mm group, respectively, P>.05), requiring further attempts for hemorrhage control (n=6), conversion to open surgery (n=1), or relaparotomy (n=1). Conclusions: The 5-mm and 10-mm LigaSure devices are similarly effective and safe during laparoscopic sigmoid colon and rectal resections. Severe bleeding from larger vessels may be observed, requiring conversion to open surgery or relaparotomy.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15785Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1089/lap.2012.0083Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGezen, Cem
dc.contributor.authorKement, Metin
dc.contributor.authorAltuntas, Yunus E.
dc.contributor.authorAksakal, Nihat
dc.contributor.authorOkkabaz, Nuri
dc.contributor.authorCivil, Osman
dc.contributor.authorVural, Selahattin
dc.contributor.authorOncel, Mustafa
dc.date.accessioned2026-10-22T10:24:32.191533067Z
dc.date.available2026-10-22T10:24:32.191533067Z
dc.date.issued2012
dc.description.abstractBackground: LigaSure™ (Covidien, Mansfield, MA) has been used in cases undergoing laparoscopic colon and rectal resections. This study aims to analyze the efficacy and safety of the 5-mm and 10-mm devices. Subjects and Methods: Patients who received a laparoscopic or hand-assisted laparoscopic operation for a tumor located in the sigmoid colon or rectum since 2006 were abstracted from a prospectively designed database, and findings were analyzed in two groups based on size of the device used during the procedure. The videotapes of the procedures were watched, and operation reports were read to obtain further information on specific intra- and postoperative complications. Demographics, tumor and operation-related information, and postoperative data were compared. Results: Among 215 (128 [59.5%] males; median age, 59.5±13.8 years) patients, data obtained from the 5-mm (n=32) and 10-mm (n=183) groups were identical regarding demographics and data related to tumor (localization and stage) and operation (number of harvested lymph nodes, conversion rates, operation time, intraoperative bleeding, transfusion requirement, reoperation rates, complications, 30-day mortality, and length of hospital stay). However, more patients underwent an anterior resection in the 10-mm group than in the 5-mm group (31.7% versus 15.6%, P<.05). Further analyses found device-related bleeding in 8 (3.7%) cases (2 [6.3%] versus 6 [3.3%] in the 5-mm versus 10-mm group, respectively, P>.05), requiring further attempts for hemorrhage control (n=6), conversion to open surgery (n=1), or relaparotomy (n=1). Conclusions: The 5-mm and 10-mm LigaSure devices are similarly effective and safe during laparoscopic sigmoid colon and rectal resections. Severe bleeding from larger vessels may be observed, requiring conversion to open surgery or relaparotomy.
dc.identifier.doi10.1089/lap.2012.0083
dc.identifier.eissn1557-9034
dc.identifier.endpage577
dc.identifier.issn1557-9034
dc.identifier.issue6
dc.identifier.pmid22458835
dc.identifier.scopus2-s2.0-84864196743
dc.identifier.startpage572
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15785
dc.identifier.volume22
dc.identifier.wosWOS:000306594400010
dc.language.isoen
dc.publisherMARY ANN LIEBERT, INC
dc.relation.ispartofJournal of Laparoendoscopic and Advanced Surgical Techniques
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.classificationSurgery
dc.subject.otherChi-Square Distribution
dc.subject.otherColon, Sigmoid
dc.subject.otherColonic Neoplasms
dc.subject.otherConversion to Open Surgery
dc.subject.otherElectrosurgery
dc.subject.otherFemale
dc.subject.otherHemostatic Techniques
dc.subject.otherHumans
dc.subject.otherIntraoperative Complications
dc.subject.otherLaparoscopy
dc.subject.otherLength of Stay
dc.subject.otherLymph Node Excision
dc.subject.otherMale
dc.subject.otherMiddle Aged
dc.subject.otherNeoadjuvant Therapy
dc.subject.otherNeoplasm Staging
dc.subject.otherOperative Time
dc.subject.otherPostoperative Complications
dc.subject.otherRectal Neoplasms
dc.subject.otherReoperation
dc.subject.otherTreatment Outcome
dc.subject.othersealant
dc.subject.otheradult
dc.subject.otheraged
dc.subject.otheranastomosis leakage
dc.subject.otherarticle
dc.subject.otherbile duct fistula
dc.subject.othercancer staging
dc.subject.otherclinical effectiveness
dc.subject.othercolon adenocarcinoma
dc.subject.othercolon polyp
dc.subject.othercomparative effectiveness
dc.subject.othercontrolled study
dc.subject.otherdevice safety
dc.subject.otherempyema
dc.subject.otherequipment design
dc.subject.otherhand assisted laparoscopy
dc.subject.otherhemostasis
dc.subject.otherhuman
dc.subject.otherileus
dc.subject.otherintestine injury
dc.subject.otherlymph node
dc.subject.othermajor clinical study
dc.subject.otheroperation duration
dc.subject.otherperoperative complication
dc.subject.otherpostoperative complication
dc.subject.otherpostoperative hemorrhage
dc.subject.otherpriority journal
dc.subject.otherrectum carcinoma
dc.subject.otherrectum polyp
dc.subject.otherrisk assessment
dc.subject.othersurgical infection
dc.subject.othersurgical mortality
dc.subject.othersurgical risk
dc.subject.othertransfusion
dc.subject.othertumor localization
dc.titleSafety and effectiveness of 5-mm and 10-mm electrothermal bipolar vessel sealers (LigaSure) in laparoscopic resections for sigmoid colon and rectal cancers
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex3
rdl.citation.scopus3
rdl.citation.wos3
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)