An improved 0.8 V OC model based GMPPT technique for module level photovoltaic power optimizers

MakaleYalnız künyeScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Photovoltaic modules may experience some mismatching conditions that affect their available power capacity, causing inefficient maximum power point tracking (MPPT). Furthermore, their power-voltage (P-V) characteristic curve becomes a multi-peak structure in such conditions owing to the presence of bypass diodes included since every part of the modules may receive different solar irradiance. By taking into account these facts, this paper introduces an improved global MPPT technique comprising 0.8 V OC model and the limited and adaptive scan approach. The proposed technique eliminates the requirement of some threshold value, leading to unreliable operation which the classical 0.8 V OC model based studies suffer from. Furthermore, the tracking time has been reduced substantially with the proposed technique by limiting scanning interval. Performance of the proposed technique has been verified by experimental studies and compared with classical 0.8 V OC model and a full scanning technique, which have been already presented in the literature. Experimental results show that the proposed technique is simple to be implemented and it has better performance than classical 0.8 V OC model, full scanning, and perturb and observe algorithms. Therefore, the proposed technique is feasible and it can be used technically in module level distributed MPPT (DMPPT) applications.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14987Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/tia.2018.2885216Yayıncı resmi DOI adresi
Atıflar
Scopus
65
WoS
49
OpenAlex
64
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBasoglu, Mustafa Engin
dc.date.accessioned2026-10-22T10:23:25.449810515Z
dc.date.available2026-10-22T10:23:25.449810515Z
dc.date.issued2019
dc.description.abstractPhotovoltaic modules may experience some mismatching conditions that affect their available power capacity, causing inefficient maximum power point tracking (MPPT). Furthermore, their power-voltage (P-V) characteristic curve becomes a multi-peak structure in such conditions owing to the presence of bypass diodes included since every part of the modules may receive different solar irradiance. By taking into account these facts, this paper introduces an improved global MPPT technique comprising 0.8 V OC model and the limited and adaptive scan approach. The proposed technique eliminates the requirement of some threshold value, leading to unreliable operation which the classical 0.8 V OC model based studies suffer from. Furthermore, the tracking time has been reduced substantially with the proposed technique by limiting scanning interval. Performance of the proposed technique has been verified by experimental studies and compared with classical 0.8 V OC model and a full scanning technique, which have been already presented in the literature. Experimental results show that the proposed technique is simple to be implemented and it has better performance than classical 0.8 V OC model, full scanning, and perturb and observe algorithms. Therefore, the proposed technique is feasible and it can be used technically in module level distributed MPPT (DMPPT) applications.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK, (116E283)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK
dc.identifier.articlenumber8565882
dc.identifier.doi10.1109/tia.2018.2885216
dc.identifier.eissn1939-9367
dc.identifier.endpage1921
dc.identifier.issn0093-9994
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85058136865
dc.identifier.startpage1913
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14987
dc.identifier.volume55
dc.identifier.wosWOS:000460318500081
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.conference17th IEEE International Conference on Environment and Electrical Engineering (IEEE EEEIC) / 1st IEEE Industrial and Commercial Power Systems Europe Conference (IEEE I and CPS Europe)
dc.relation.ispartofIEEE Transactions on Industry Applications
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectGlobal maximum power point tracking (GMPPT)
dc.subjectmodule level maximum power point tracking (MPPT)
dc.subjectpartial shading condition (PSC)
dc.subjectphotovoltaic (PV) module
dc.subjectPV optimizer
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationEngineering
dc.subject.otherMaximum power point trackers
dc.subject.otherPhotovoltaic cells
dc.subject.otherScanning
dc.subject.otherCharacteristic curve
dc.subject.otherGlobal maximum power point tracking
dc.subject.otherMaximum power point tracking (mppt) (MPP)
dc.subject.otherMulti-peak structure
dc.subject.otherOptimizers
dc.subject.otherPartial shading
dc.subject.otherPerturb and observe
dc.subject.otherPhotovoltaic modules
dc.subject.otherGlobal optimization
dc.titleAn improved 0.8 V OC model based GMPPT technique for module level photovoltaic power optimizers
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex64
rdl.citation.scopus65
rdl.citation.wos49
rdl.conference.dateJUN 06-09, 2017
rdl.conference.placeMilan, ITALY
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)
rdl.wos.indexConference Proceedings Citation Index - Science (CPCI-S)