Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance
Özet
Aim: This study analyzed the concurrent validity of the Optojump infrared photocell system for estimating lower limb peak power by comparing it with the 15 s Wingate anaerobic test (WAnT) and examining relationships with sprint performance indicators. Methods: Twelve physically active university students (ten males, two females; age: 23.39 ± 1.47 years; body mass: 73.08 ± 9.19 kg; height: 173.67 ± 6.97 cm; BMI: 24.17 ± 1.48 kg·m−2) completed a cross-sectional validation protocol. Participants performed WAnT on a calibrated Monark ergometer (7.5% body weight for males, 5.5% for females), 30 s continuous jump tests using the Optojump system (Microgate, Italy), and 30 m sprint assessments with 10 m and 20 m split times. Peak power was expressed in absolute (W), relative (W·kg−1), and allometric (W·kg−0.67) terms. Results: Thirty-second continuous jump testing produced systematically higher peak power values across all metrics (p < 0.001). Mean differences indicated large effect sizes: relative power (Cohen’s d = 0.99; 18.263 ± 4.243 vs. 10.99 ± 1.58 W·kg−1), absolute power (d = 0.86; 1381.71 ± 393.44 vs. 807.28 ± 175.45 W), and allometric power (d = 0.79). Strong correlations emerged between protocols, with absolute power showing the strongest association (r = 0.842, p < 0.001). Linear regression analysis revealed that 30 s continuous jump-derived measurements explained 71% of the variance in Wingate outcomes (R2 = 0.710, p < 0.001). Sprint performance showed equivalent predictive capacity for both tests (Wingate: R2 = 0.66; 30 s continuous jump: R2 = 0.67). Conclusions: The Optojump infrared photocell system provides a valid and practical alternative to laboratory-based ergometry for assessing lower limb anaerobic power. While it systematically overestimates absolute values compared with the Wingate anaerobic test, its strong concurrent validity (r > 0.80), large effect sizes, and equivalent predictive ability for sprint performance (R2 = 0.66–0.71) confirm its reliability as a field-based assessment tool. These findings underscore the importance of sport-specific, weight-bearing assessment technologies in modern sports biomechanics, providing coaches, practitioners, and clinicians with a feasible method for monitoring performance, talent identification, and training optimization. The results further suggest that Optojump-based protocols can bridge the gap between laboratory precision and ecological validity, supporting both athletic performance enhancement and injury prevention strategies.
Anahtar Kelimeler
- Scopus
- 3
- WoS
- 2
- OpenAlex
- 2
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Khemiri, Aymen | |
| dc.contributor.author | Negra, Yassine | |
| dc.contributor.author | Ceylan, Halil İbrahim | |
| dc.contributor.author | Hajri, Manel | |
| dc.contributor.author | Njah, Abdelmonom | |
| dc.contributor.author | Hachana, Younes | |
| dc.contributor.author | Yıldız, Mevlüt | |
| dc.contributor.author | Bayrakdaroğlu, Serdar | |
| dc.contributor.author | Muntean, Raul Ioan | |
| dc.contributor.author | Attia, Ahmed | |
| dc.date.accessioned | 2026-10-22T10:22:14.412077795Z | |
| dc.date.available | 2026-10-22T10:22:14.412077795Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Aim: This study analyzed the concurrent validity of the Optojump infrared photocell system for estimating lower limb peak power by comparing it with the 15 s Wingate anaerobic test (WAnT) and examining relationships with sprint performance indicators. Methods: Twelve physically active university students (ten males, two females; age: 23.39 ± 1.47 years; body mass: 73.08 ± 9.19 kg; height: 173.67 ± 6.97 cm; BMI: 24.17 ± 1.48 kg·m−2) completed a cross-sectional validation protocol. Participants performed WAnT on a calibrated Monark ergometer (7.5% body weight for males, 5.5% for females), 30 s continuous jump tests using the Optojump system (Microgate, Italy), and 30 m sprint assessments with 10 m and 20 m split times. Peak power was expressed in absolute (W), relative (W·kg−1), and allometric (W·kg−0.67) terms. Results: Thirty-second continuous jump testing produced systematically higher peak power values across all metrics (p < 0.001). Mean differences indicated large effect sizes: relative power (Cohen’s d = 0.99; 18.263 ± 4.243 vs. 10.99 ± 1.58 W·kg−1), absolute power (d = 0.86; 1381.71 ± 393.44 vs. 807.28 ± 175.45 W), and allometric power (d = 0.79). Strong correlations emerged between protocols, with absolute power showing the strongest association (r = 0.842, p < 0.001). Linear regression analysis revealed that 30 s continuous jump-derived measurements explained 71% of the variance in Wingate outcomes (R2 = 0.710, p < 0.001). Sprint performance showed equivalent predictive capacity for both tests (Wingate: R2 = 0.66; 30 s continuous jump: R2 = 0.67). Conclusions: The Optojump infrared photocell system provides a valid and practical alternative to laboratory-based ergometry for assessing lower limb anaerobic power. While it systematically overestimates absolute values compared with the Wingate anaerobic test, its strong concurrent validity (r > 0.80), large effect sizes, and equivalent predictive ability for sprint performance (R2 = 0.66–0.71) confirm its reliability as a field-based assessment tool. These findings underscore the importance of sport-specific, weight-bearing assessment technologies in modern sports biomechanics, providing coaches, practitioners, and clinicians with a feasible method for monitoring performance, talent identification, and training optimization. The results further suggest that Optojump-based protocols can bridge the gap between laboratory precision and ecological validity, supporting both athletic performance enhancement and injury prevention strategies. | |
| dc.identifier.articlenumber | 10741 | |
| dc.identifier.doi | 10.3390/app151910741 | |
| dc.identifier.eissn | 2076-3417 | |
| dc.identifier.issn | 2076-3417 | |
| dc.identifier.issue | 19 | |
| dc.identifier.scopus | 2-s2.0-105032648848 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/14096 | |
| dc.identifier.volume | 15 | |
| dc.identifier.wos | WOS:001594665300001 | |
| dc.language.iso | en | |
| dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | |
| dc.relation.ispartof | Applied Sciences (Switzerland) | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | anaerobic power | |
| dc.subject | athletic performance | |
| dc.subject | field-based assessment | |
| dc.subject | optojump | |
| dc.subject | sports biomechanics | |
| dc.subject | sprint performance | |
| dc.subject | wingate anaerobic test | |
| dc.subject.classification | Chemistry, Multidisciplinary | |
| dc.subject.classification | Engineering, Multidisciplinary | |
| dc.subject.classification | Materials Science, Multidisciplinary | |
| dc.subject.classification | Physics, Applied | |
| dc.subject.classification | Chemistry | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Materials Science | |
| dc.subject.classification | Physics | |
| dc.subject.other | Biomechanics | |
| dc.subject.other | Exercise equipment | |
| dc.subject.other | Linear regression | |
| dc.subject.other | Anaerobic power | |
| dc.subject.other | Anaerobics | |
| dc.subject.other | Athletic performance | |
| dc.subject.other | Field-based assessment | |
| dc.subject.other | Lower limb | |
| dc.subject.other | Optojump | |
| dc.subject.other | Performance | |
| dc.subject.other | Sport biomechanics | |
| dc.subject.other | Sprint performance | |
| dc.subject.other | Wingate anerobic test | |
| dc.subject.other | Sports | |
| dc.title | Concurrent Validity of the Optojump Infrared Photocell System in Lower Limb Peak Power Assessment: Comparative Analysis with the Wingate Anaerobic Test and Sprint Performance | |
| dc.type | Article | |
| rdl.citation.openalex | 2 | |
| rdl.citation.scopus | 3 | |
| rdl.citation.wos | 2 | |
| rdl.oa.status | gold | |
| rdl.oa.url | https://www.mdpi.com/2076-3417/15/19/10741/pdf?version=1759724915 | |
| rdl.scopus.quartile | Q2 | |
| rdl.sdg | SDG03 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |

