Determination of the ground-building relationships in the KTU campus area with microtremor measurements

BildiriYalnız künye
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

Microtremor measurement obtained by ground vibrations is one of the useful methods for determination of ground characteristics. Also the method has been using to specify building resonance risk during earthquakes in the last decades. In this study, single station microtremor recordings have been taken on the ground and at the 6 buildings in the KTU campus area. The measurements taken on the ground and in the buildings have been evaluated by Nakamura (H/V ratio) method. The eastern of the campus area presents Class-IV and the middle and western part of the campus present Class-II- Class-III according to Kanai and Tanaka ground classification. The predominant frequencies of the buildings are not in a harmony with the values of the ground. It can be deduce that the resonance risk is low for these buildings during the earthquakes. The H/V ratios of the ground change between 1-3 and lower than the buildings ratios which change between 5.0-8.5.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/11358Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3997/2214-4609.201601977Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
1
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBeker, Y.
dc.contributor.authorSayil, N.
dc.contributor.authorAkin, O.
dc.contributor.authorCoban, K.H.
dc.date.accessioned2026-10-22T10:18:56.380530931Z
dc.date.available2026-10-22T10:18:56.380530931Z
dc.date.issued2016
dc.description.abstractMicrotremor measurement obtained by ground vibrations is one of the useful methods for determination of ground characteristics. Also the method has been using to specify building resonance risk during earthquakes in the last decades. In this study, single station microtremor recordings have been taken on the ground and at the 6 buildings in the KTU campus area. The measurements taken on the ground and in the buildings have been evaluated by Nakamura (H/V ratio) method. The eastern of the campus area presents Class-IV and the middle and western part of the campus present Class-II- Class-III according to Kanai and Tanaka ground classification. The predominant frequencies of the buildings are not in a harmony with the values of the ground. It can be deduce that the resonance risk is low for these buildings during the earthquakes. The H/V ratios of the ground change between 1-3 and lower than the buildings ratios which change between 5.0-8.5.
dc.identifier.doi10.3997/2214-4609.201601977
dc.identifier.scopus2-s2.0-85086687210
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/11358
dc.language.isoen
dc.publisherEuropean Association of Geoscientists and Engineers, EAGE
dc.relation.conference22nd European Meeting of Environmental and Engineering Geophysics, Near Surface Geoscience 2016
dc.relation.ispartof22nd European Meeting of Environmental and Engineering Geophysics, Near Surface Geoscience 2016
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.otherEarthquakes
dc.subject.otherGeology
dc.subject.otherClass II
dc.subject.otherGround building
dc.subject.otherGround vibration
dc.subject.otherH/V ratio
dc.subject.otherMicro-tremor measurements
dc.subject.otherMicrotremors
dc.subject.otherPredominant frequency
dc.subject.otherBuildings
dc.titleDetermination of the ground-building relationships in the KTU campus area with microtremor measurements
dc.typeConference Object
rdl.citation.openalex0
rdl.citation.scopus1
rdl.conference.date4 September 2016 through 8 September 2016
rdl.conference.placeBarcelona
rdl.oa.statusclosed
rdl.sdgSDG11
rdl.source.indexSCOPUS