Optimization of non-traditional tuned mass damper for damped structures under harmonic excitation

MakaleAçık Erişim
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Tuned mass dampers (TMDs) are used to reduce dynamic vibrations of structures under environmental loads such as wind or seismic excitation. In this paper, the optimum design of nontraditional tuned mass dampers (NT-TMD) attached to a damped main structure under harmonic excitation was investigated. Unlike the traditional TMD, the damping element in NT-TMD is directly connected to the ground. In this study, the effectiveness of NT-TMD on the attenuation of vibrations on the damped main system under harmonic load is investigated. The optimum parameters of the NT-TMD are obtained by using the hybrid pattern search (HPS) technique. According to numerical results, it is seen that non-traditional TMD is more effective than traditional TMD in reducing vibration.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/17409Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.17482/uumfd.878114Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKahya, Volkan
dc.contributor.authorAraz, Onur
dc.date.accessioned2026-10-22T10:38:52.891851577Z
dc.date.available2026-10-22T10:38:52.891851577Z
dc.date.issued2021
dc.description.abstractTuned mass dampers (TMDs) are used to reduce dynamic vibrations of structures under environmental loads such as wind or seismic excitation. In this paper, the optimum design of nontraditional tuned mass dampers (NT-TMD) attached to a damped main structure under harmonic excitation was investigated. Unlike the traditional TMD, the damping element in NT-TMD is directly connected to the ground. In this study, the effectiveness of NT-TMD on the attenuation of vibrations on the damped main system under harmonic load is investigated. The optimum parameters of the NT-TMD are obtained by using the hybrid pattern search (HPS) technique. According to numerical results, it is seen that non-traditional TMD is more effective than traditional TMD in reducing vibration.
dc.identifier.doi10.17482/uumfd.878114
dc.identifier.eissn2148-4155
dc.identifier.endpage1034
dc.identifier.issn2148-4147
dc.identifier.issue3
dc.identifier.startpage1021
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/17409
dc.identifier.volume26
dc.language.isoen
dc.relation.ispartofUludağ Üniversitesi Mühendislik Fakültesi Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMühendislik, Makine
dc.subjectİnşaat Mühendisliği
dc.titleOptimization of non-traditional tuned mass damper for damped structures under harmonic excitation
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex22
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/1569373
rdl.sdgSDG09
rdl.source.indexTRDIZIN