Building-up a code for the purpose of TRUE coincidence summing correction in gamma-ray spectrometry with EGS4
MakaleYalnız künye
Özet
In the presented study, a code was created for the purpose of true coincidence summing (TCS) correction factors for 134Cs. The created code was implemented in EGS4 Monte Carlo simulation package. TCS factors were determined for nine different energies for different detector-source geometries. The calculated results were successfully validated by an empirical method using a point 134Cs radioactive source and a p-type HPGe detector having 55% relative efficiency. Although the code created gives TCS factors only for 134Cs, the technique presented can be used to obtain the factors for any radionuclide used in gamma-ray spectrometry.
Anahtar Kelimeler
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15608Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Celik, Necati | |
| dc.contributor.author | Altin, Duygu | |
| dc.contributor.author | Cevik, Ugur | |
| dc.date.accessioned | 2026-10-22T10:24:15.275749439Z | |
| dc.date.available | 2026-10-22T10:24:15.275749439Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | In the presented study, a code was created for the purpose of true coincidence summing (TCS) correction factors for 134Cs. The created code was implemented in EGS4 Monte Carlo simulation package. TCS factors were determined for nine different energies for different detector-source geometries. The calculated results were successfully validated by an empirical method using a point 134Cs radioactive source and a p-type HPGe detector having 55% relative efficiency. Although the code created gives TCS factors only for 134Cs, the technique presented can be used to obtain the factors for any radionuclide used in gamma-ray spectrometry. | |
| dc.description.sponsorship | TUBİTAK | |
| dc.description.sponsorship | Türkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK | |
| dc.identifier.doi | 10.1016/j.radphyschem.2015.07.002 | |
| dc.identifier.endpage | 163 | |
| dc.identifier.issn | 0969-806X | |
| dc.identifier.scopus | 2-s2.0-84936949469 | |
| dc.identifier.startpage | 158 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/15608 | |
| dc.identifier.volume | 115 | |
| dc.identifier.wos | WOS:000359885700025 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Ltd | |
| dc.relation.ispartof | Radiation Physics and Chemistry | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | <sup>134</sup>Cs | |
| dc.subject | EGS4 | |
| dc.subject | Monte Carlo | |
| dc.subject | True coincidence summing correction | |
| dc.subject.classification | Chemistry, Physical | |
| dc.subject.classification | Nuclear Science & Technology | |
| dc.subject.classification | Physics, Atomic, Molecular & Chemical | |
| dc.subject.classification | Chemistry | |
| dc.subject.classification | Physics | |
| dc.subject.other | Cesium | |
| dc.subject.other | Codes (symbols) | |
| dc.subject.other | Gamma ray spectrometers | |
| dc.subject.other | Intelligent systems | |
| dc.subject.other | Monte Carlo methods | |
| dc.subject.other | Radioactivity | |
| dc.subject.other | Spectroscopy | |
| dc.subject.other | cesium 134 | |
| dc.subject.other | radioisotope | |
| dc.subject.other | Coincidence-summing | |
| dc.subject.other | Correction factors | |
| dc.subject.other | EGS4 | |
| dc.subject.other | EGS4 Monte Carlo Simulation | |
| dc.subject.other | Empirical method | |
| dc.subject.other | Gamma ray spectrometry | |
| dc.subject.other | Radioactive sources | |
| dc.subject.other | Relative efficiency | |
| dc.subject.other | Article | |
| dc.subject.other | gamma spectrometry | |
| dc.subject.other | mathematical analysis | |
| dc.subject.other | Monte Carlo method | |
| dc.subject.other | probability | |
| dc.subject.other | radiation detection | |
| dc.subject.other | radiation energy | |
| dc.subject.other | radioisotope decay | |
| dc.subject.other | Gamma rays | |
| dc.title | Building-up a code for the purpose of TRUE coincidence summing correction in gamma-ray spectrometry with EGS4 | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 4 | |
| rdl.citation.scopus | 5 | |
| rdl.citation.wos | 4 | |
| rdl.oa.status | closed | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |