Dynamic analysis and seismic performance evaluation of above-ground liquid-containing tanks

MakaleYalnız künye
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

A large number of industrial facilities were damaged during the 1999 Mw 7.4 Kocaeli, Turkey earthquake. One of those industrial facilities, Habas plant located within 10 km of the fault trace, provides liquefied gases to commercial plants and medical facilities. Two of the three tanks at the Habas facility collapsed during the earthquake. The main objectives of this paper were to evaluate the seismic performance of tanks and investigate the parameters influencing the dynamic behaviour. Simplified and finite element dynamic analyses of the tanks are carried out including the effect of liquefied gas-structure interaction using a ground motion recorded at a nearby site. The vulnerabilities of the structural system, the observed performance, and damage pattern are discussed by comparing the dynamic analysis results with the strength and deformation capacity of the support columns. The dynamic analysis results from a simplified three-mass model and a finite element model confirmed that the axial and lateral strength of the columns supporting the two nearly full tanks were not sufficient to resist the demand imposed during the earthquake. Consistent with the observed structural performance, an elastic response is predicted for the columns supporting the undamaged 25% full identical tank.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14931Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSezen, Halil
dc.contributor.authorLivaoglu, Ramazan
dc.contributor.authorDogangun, Adem
dc.date.accessioned2026-10-22T10:23:20.831968298Z
dc.date.available2026-10-22T10:23:20.831968298Z
dc.date.issued2008
dc.description.abstractA large number of industrial facilities were damaged during the 1999 Mw 7.4 Kocaeli, Turkey earthquake. One of those industrial facilities, Habas plant located within 10 km of the fault trace, provides liquefied gases to commercial plants and medical facilities. Two of the three tanks at the Habas facility collapsed during the earthquake. The main objectives of this paper were to evaluate the seismic performance of tanks and investigate the parameters influencing the dynamic behaviour. Simplified and finite element dynamic analyses of the tanks are carried out including the effect of liquefied gas-structure interaction using a ground motion recorded at a nearby site. The vulnerabilities of the structural system, the observed performance, and damage pattern are discussed by comparing the dynamic analysis results with the strength and deformation capacity of the support columns. The dynamic analysis results from a simplified three-mass model and a finite element model confirmed that the axial and lateral strength of the columns supporting the two nearly full tanks were not sufficient to resist the demand imposed during the earthquake. Consistent with the observed structural performance, an elastic response is predicted for the columns supporting the undamaged 25% full identical tank.
dc.identifier.doi10.1016/j.engstruct.2007.05.002
dc.identifier.endpage803
dc.identifier.issn0141-0296
dc.identifier.issue3
dc.identifier.scopus2-s2.0-38849179966
dc.identifier.startpage794
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14931
dc.identifier.volume30
dc.language.isoen
dc.relation.ispartofEngineering Structures
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAbove-ground tanks
dc.subjectColumn failure
dc.subjectEarthquake damage
dc.subjectLiquefied gas-structure interaction
dc.subjectSloshing effect
dc.subject.otherEurasia
dc.subject.otherTurkey
dc.subject.otherDynamic analysis
dc.subject.otherEarthquake effects
dc.subject.otherFinite element method
dc.subject.otherFluid structure interaction
dc.subject.otherLiquid sloshing
dc.subject.otherMathematical models
dc.subject.otherSeismic response
dc.subject.otherTanks (containers)
dc.subject.otherdamage mechanics
dc.subject.otherdeformation mechanism
dc.subject.otherdynamic response
dc.subject.otherearthquake damage
dc.subject.otherground motion
dc.subject.otherhydraulic structure
dc.subject.otherKocaeli earthquake 1999
dc.subject.otherperformance assessment
dc.subject.otherseismic design
dc.subject.otherstructural response
dc.subject.otherSloshing effect
dc.titleDynamic analysis and seismic performance evaluation of above-ground liquid-containing tanks
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex123
rdl.citation.scopus116
rdl.oa.statusclosed
rdl.sdgSDG09
rdl.source.indexSCOPUS