Long term outdoor testing of the PV systems at different climatic conditions or different systems under the same ambient conditions are extremely important in producing policies for the transition to renewables. The present research is the testing of three different PV systems under the same climatic conditions of central Anatolia, after four years of operation. The systems consist of a mono-Si, an a-Si thin film and a CdTe thin film arrays. Different calculation procedures of the input solar irradiation on tilted surface are used for comparison. Performances together with degradation rates are computed using different procedures and also using the measured solar data of 20 km away from the installed systems. The accuracy is verified using 4 months of simultaneous measurements. The results showed that the aforementioned different input calculation procedures of the performances are important and determinant. The 44-months-average efficiencies of these three systems are calculated to be 11.86%, 6.40% and 5.30%, respectively. The degradation rates of these systems are obtained as 0.40%, 1.88% and 10.60%, respectively. Although the degradation rates that are calculated for the first two systems are quite similar to those appeared in the literature, CdTe system is considerably higher than those given in the literature.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13069Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzden, Talat
dc.contributor.authorAkinoglu, Bulent G.
dc.contributor.authorTuran, Rasit
dc.date.accessioned2026-10-22T10:20:53.838000192Z
dc.date.available2026-10-22T10:20:53.838000192Z
dc.date.issued2017
dc.description.abstractLong term outdoor testing of the PV systems at different climatic conditions or different systems under the same ambient conditions are extremely important in producing policies for the transition to renewables. The present research is the testing of three different PV systems under the same climatic conditions of central Anatolia, after four years of operation. The systems consist of a mono-Si, an a-Si thin film and a CdTe thin film arrays. Different calculation procedures of the input solar irradiation on tilted surface are used for comparison. Performances together with degradation rates are computed using different procedures and also using the measured solar data of 20 km away from the installed systems. The accuracy is verified using 4 months of simultaneous measurements. The results showed that the aforementioned different input calculation procedures of the performances are important and determinant. The 44-months-average efficiencies of these three systems are calculated to be 11.86%, 6.40% and 5.30%, respectively. The degradation rates of these systems are obtained as 0.40%, 1.88% and 10.60%, respectively. Although the degradation rates that are calculated for the first two systems are quite similar to those appeared in the literature, CdTe system is considerably higher than those given in the literature.
dc.description.sponsorshipTUBITAK
dc.description.sponsorshipMinisterio de Fomento
dc.identifier.doi10.1016/j.renene.2016.08.045
dc.identifier.eissn1879-0682
dc.identifier.endpage195
dc.identifier.issn0960-1481
dc.identifier.scopus2-s2.0-84984788956
dc.identifier.startpage182
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13069
dc.identifier.volume101
dc.identifier.wosWOS:000388775700018
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofRenewable Energy
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDegradation rate
dc.subjectOutdoor testing of solar PV
dc.subjectPerformance of PV systems
dc.subject.classificationGreen & Sustainable Science & Technology
dc.subject.classificationEnergy & Fuels
dc.subject.classificationScience & Technology - Other Topics
dc.subject.otherAnatolia
dc.subject.otherTurkey
dc.subject.otherCadmium telluride
dc.subject.otherPhotovoltaic cells
dc.subject.otherThin films
dc.subject.otherAmbient conditions
dc.subject.otherCalculation procedure
dc.subject.otherClimatic conditions
dc.subject.otherDegradation rate
dc.subject.otherPV system
dc.subject.otherSimultaneous measurement
dc.subject.otherSolar irradiation
dc.subject.otherSolar PVs
dc.subject.otherdegradation
dc.subject.otherenergy efficiency
dc.subject.otherenergy policy
dc.subject.otherirradiation
dc.subject.otherlong-term change
dc.subject.otherperformance assessment
dc.subject.otherphotovoltaic system
dc.subject.otherrenewable resource
dc.subject.othersolar power
dc.subject.othertesting method
dc.titleLong term outdoor performances of three different on-grid PV arrays in central Anatolia – An extended analysis
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex76
rdl.citation.scopus77
rdl.citation.wos63
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.oa.urlhttps://hdl.handle.net/11511/45053
rdl.sdgSDG07
rdl.sdgSDG13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)