The effect of energy resolution of detection instrument on mass attenuation coefficient
Özet
The effect of energy resolution of two detection systems, HPGe and NaI(Tl), was determined by Monte Carlo (MC) calculation on mass attenuation coefficients of magnesium (Mg) and tungsten (W). In order to reveal the energy resolution effect, the detectors' collimator diameters were changed from 2 mm to 20 mm while sending collimated photon beams to the absorber material. It was observed that mass attenuation coefficients were increased with increasing collimator diameters. The performances of HPGe and NaI(Tl) detectors were quantified. The calculated results were compared with experimental results for Mg at energy of gamma rays 662 keV for different collimator diameters using both HPGe and NaI(Tl). It was observed that the MC calculation results were in a good agreement with the experimental data within the relative error from around 4% to 8%.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Çelik, N. | |
| dc.contributor.author | Özen, S.A. | |
| dc.contributor.author | Demirtaş, Ö.F. | |
| dc.contributor.author | Çevik, U. | |
| dc.date.accessioned | 2026-10-22T10:20:46.666077315Z | |
| dc.date.available | 2026-10-22T10:20:46.666077315Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | The effect of energy resolution of two detection systems, HPGe and NaI(Tl), was determined by Monte Carlo (MC) calculation on mass attenuation coefficients of magnesium (Mg) and tungsten (W). In order to reveal the energy resolution effect, the detectors' collimator diameters were changed from 2 mm to 20 mm while sending collimated photon beams to the absorber material. It was observed that mass attenuation coefficients were increased with increasing collimator diameters. The performances of HPGe and NaI(Tl) detectors were quantified. The calculated results were compared with experimental results for Mg at energy of gamma rays 662 keV for different collimator diameters using both HPGe and NaI(Tl). It was observed that the MC calculation results were in a good agreement with the experimental data within the relative error from around 4% to 8%. | |
| dc.identifier.articlenumber | P10012 | |
| dc.identifier.doi | 10.1088/1748-0221/13/10/p10012 | |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.issue | 10 | |
| dc.identifier.scopus | 2-s2.0-85056112438 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/12976 | |
| dc.identifier.volume | 13 | |
| dc.identifier.wos | WOS:000446671600003 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Physics Publishing | |
| dc.relation.ispartof | Journal of Instrumentation | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Data analysis | |
| dc.subject | Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators) | |
| dc.subject | Simulation methods and programs | |
| dc.subject | Solid state detectors | |
| dc.subject.classification | Instruments & Instrumentation | |
| dc.subject.other | Data reduction | |
| dc.subject.other | Gamma rays | |
| dc.subject.other | Germanium compounds | |
| dc.subject.other | Iodine compounds | |
| dc.subject.other | Ionization | |
| dc.subject.other | Scintillation counters | |
| dc.subject.other | Semiconductor detectors | |
| dc.subject.other | Sodium Iodide | |
| dc.subject.other | Absorber material | |
| dc.subject.other | Calculation results | |
| dc.subject.other | Detection instruments | |
| dc.subject.other | Detection system | |
| dc.subject.other | Emission process | |
| dc.subject.other | Energy resolutions | |
| dc.subject.other | Mass attenuation coefficients | |
| dc.subject.other | Solid state detectors | |
| dc.subject.other | Phosphorus compounds | |
| dc.title | The effect of energy resolution of detection instrument on mass attenuation coefficient | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 7 | |
| rdl.citation.scopus | 8 | |
| rdl.citation.wos | 7 | |
| rdl.oa.status | bronze | |
| rdl.oa.url | https://iopscience.iop.org/article/10.1088/1748-0221/13/10/P10012/pdf | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |