An Efficient 1D Autoencoder-Based Approach for R-Peaks Detection in Electrocardiogram Signals

BildiriYalnız künye
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Electrocardiogram (ECG) signal which is composition of multiple segments such as P-wave, QRS complex and T-wave plays a crucial role in evaluating human heart cardiac diagnosis. For an analysis of cardiac diagnosis, it is required that clinicians scan the ECG signal for R-peaks (the highest peak of the QRS complex) detection, which relies on their expertise and takes enormous time. In order to provide more realistic treatment of cardiovascular diseases in the ECG signal with noises and different characteristics, computer-based R-peaks detection approaches have been actively developed in the research article for many years and generally compose of two major operations; preprocessing and decision. Contrary to previous approaches which require high computational costs and complexity, appropriate initial parameters, a novel CNN based approach is presented for R-peaks detection in this paper. Both qualitative and quantitative analysis are performed in the real ECG signal taken from typical MIT-BIH arrhythmia database. In order to validate the success of the recommended approach, total 18 different R-peaks detection approaches reported in the literature are compared by utilizing performance evaluation metrics. Average values of sensitivity, positive predictivity, error rate, accuracy and f-score are computed as 99,96%, 99,95%, 0,09%, 99,90% and 99,95% respectively, which are the best values among well-established studies for R-peaks detection. It is demonstrated with qualitative and quantitative results that better performance is achieved by our suggested approach.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12734Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDogan, Ramazan Ozgur
dc.contributor.authorDogan, Hulya
dc.contributor.authorKayikcioglu, Temel
dc.date.accessioned2026-10-22T10:20:28.773743129Z
dc.date.available2026-10-22T10:20:28.773743129Z
dc.date.issued2023
dc.description.abstractElectrocardiogram (ECG) signal which is composition of multiple segments such as P-wave, QRS complex and T-wave plays a crucial role in evaluating human heart cardiac diagnosis. For an analysis of cardiac diagnosis, it is required that clinicians scan the ECG signal for R-peaks (the highest peak of the QRS complex) detection, which relies on their expertise and takes enormous time. In order to provide more realistic treatment of cardiovascular diseases in the ECG signal with noises and different characteristics, computer-based R-peaks detection approaches have been actively developed in the research article for many years and generally compose of two major operations; preprocessing and decision. Contrary to previous approaches which require high computational costs and complexity, appropriate initial parameters, a novel CNN based approach is presented for R-peaks detection in this paper. Both qualitative and quantitative analysis are performed in the real ECG signal taken from typical MIT-BIH arrhythmia database. In order to validate the success of the recommended approach, total 18 different R-peaks detection approaches reported in the literature are compared by utilizing performance evaluation metrics. Average values of sensitivity, positive predictivity, error rate, accuracy and f-score are computed as 99,96%, 99,95%, 0,09%, 99,90% and 99,95% respectively, which are the best values among well-established studies for R-peaks detection. It is demonstrated with qualitative and quantitative results that better performance is achieved by our suggested approach.
dc.identifier.doi10.1109/iceee59925.2023.00027
dc.identifier.endpage110
dc.identifier.isbn979-835030429-9
dc.identifier.scopus2-s2.0-85178997659
dc.identifier.startpage106
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12734
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.conference10th International Conference on Electrical and Electronics Engineering, ICEEE 2023
dc.relation.ispartofProceedings - 2023 10th International Conference on Electrical and Electronics Engineering, ICEEE 2023
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectelectrocardiogram signal
dc.subjectID autoencoder
dc.subjectID convolutional neural net-work
dc.subjectMIT-BIH arrhythmia
dc.subjectR-peaks detection
dc.subject.otherConvolutional neural networks
dc.subject.otherElectrocardiography
dc.subject.otherLearning systems
dc.subject.otherSeismic waves
dc.subject.otherAuto encoders
dc.subject.otherDetection approach
dc.subject.otherElectrocardiogram signal
dc.subject.otherID autoencoder
dc.subject.otherID convolutional neural net-work
dc.subject.otherMIT-BIH arrhythmia
dc.subject.otherNet work
dc.subject.otherP waves
dc.subject.otherQRS complex waves
dc.subject.otherR-peak detection
dc.subject.otherDiseases
dc.titleAn Efficient 1D Autoencoder-Based Approach for R-Peaks Detection in Electrocardiogram Signals
dc.typeConference Object
rdl.citation.openalex2
rdl.citation.scopus2
rdl.conference.date8 May 2023 through 10 May 2023
rdl.conference.placeIstanbul
rdl.oa.statusclosed
rdl.sdgSDG03
rdl.source.indexSCOPUS