Effect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape

MakaleYalnız künye

Özet

Measurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, Hac, in the presence of bias magnetic field Hdc directed along Hac are reported. It is found that the peak values of the imaginary component of ac susceptibility χ″max versus Hac trace a valley for the orientation where applied field Ha perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression jc = α(T)/Bn, choice of the bias field Hdc together with selected ac field amplitudes Hac, and dimension and geometry of sample studied. Our calculations based on critical state model with jc = α(1 - T/Tcm)p/Bn using the fitting parameters of n = 0.25, p = 2.2, Tcm = 108 K gives quite good results to compare the experimental and calculated curves.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12359Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1051/epjap/2017170266Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÖztürk, Ali
dc.contributor.authorDüzgün, Ibrahim
dc.contributor.authorÇelebi, Selahattin
dc.date.accessioned2026-10-22T10:19:59.669882160Z
dc.date.available2026-10-22T10:19:59.669882160Z
dc.date.issued2017
dc.description.abstractMeasurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, Hac, in the presence of bias magnetic field Hdc directed along Hac are reported. It is found that the peak values of the imaginary component of ac susceptibility χ″max versus Hac trace a valley for the orientation where applied field Ha perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression jc = α(T)/Bn, choice of the bias field Hdc together with selected ac field amplitudes Hac, and dimension and geometry of sample studied. Our calculations based on critical state model with jc = α(1 - T/Tcm)p/Bn using the fitting parameters of n = 0.25, p = 2.2, Tcm = 108 K gives quite good results to compare the experimental and calculated curves.
dc.description.sponsorshipTUBITAK-TBAG [107T015]
dc.identifier.articlenumber30601
dc.identifier.doi10.1051/epjap/2017170266
dc.identifier.eissn1286-0050
dc.identifier.issn1286-0042
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85037541517
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12359
dc.identifier.volume80
dc.identifier.wosWOS:000416953700001
dc.language.isoen
dc.publisherEDP Sciences
dc.relation.ispartofEPJ Applied Physics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.classificationPhysics, Applied
dc.subject.classificationPhysics
dc.subject.otherCurve fitting
dc.subject.otherMagnetic fields
dc.subject.otherMagnetic susceptibility
dc.subject.otherAC magnetic fields
dc.subject.otherAc susceptibility
dc.subject.otherBias magnetic field
dc.subject.otherCritical state models
dc.subject.otherField dependence
dc.subject.otherFitting parameters
dc.subject.otherMeasurements of
dc.subject.otherPower-law expression
dc.subject.otherCritical current density (superconductivity)
dc.titleEffect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex1
rdl.citation.scopus1
rdl.citation.wos1
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)