The comparison of different mathematical methods to determine the BOD parameters, a new developed method and impacts of these parameters variations on the design of WWTPs

MakaleAçık Erişim
  • SDG 6 · Temiz Su ve Sanitasyon

Özet

One of the most common tests for the determination of strength and organic content of wastewater is the biochemical oxygen demand (BOD). This test is widely applied to define organic water pollution and to control the performance of wastewater treatment plants. Generally, BOD is standardized by the measurement of oxygen consumption in 5days (BOD5). But, determination of the ultimate biochemical oxygen demand (BODu), which is taken 28days and the reaction rate constant (k) are necessary to understand the organic strength of the wastewater. In this study, the different mathematical methods in order to determine the BOD parameters (BODu, k) and two different BOD test method (respirometer and dilution method) are investigated comparatively. Also, a new method based on cubic spline method to estimate ultimate BOD values is developed. Moreover, the impacts of BOD parameters on the design of an activated sludge and aerated lagoon systems are analyzed by using a written user-friend program, which is developed for designing WWTPs by the mean of C++ programming language.Analytical results show that there is a satisfactory linear relationship between respirometric and dilution BOD values. Also, the mathematical methods, including new developed method generally provide consistent results with high correlation coefficients. On the other hand, it is found that LOG differences method for respirometric test and the new developed method for dilution test do not give good correlation coefficients. Moreover, activated sludge and aerated lagoons systems' sizes show significant changing depending on the variations of the BOD parameters. Consequently, BOD parameters show significant changes depending on the different test and mathematical methods. Therefore, the changing of these parameters impact a lot of situation such as ultimate BOD estimation, the wastewater treatment plants design, the dimensions of the plants and cost of the plants.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12052Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.apm.2013.07.013Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSibil, Rahim
dc.contributor.authorBerkun, Mehmet
dc.contributor.authorBekiroglu, Serkan
dc.date.accessioned2026-10-22T10:19:37.892626009Z
dc.date.available2026-10-22T10:19:37.892626009Z
dc.date.issued2014
dc.description.abstractOne of the most common tests for the determination of strength and organic content of wastewater is the biochemical oxygen demand (BOD). This test is widely applied to define organic water pollution and to control the performance of wastewater treatment plants. Generally, BOD is standardized by the measurement of oxygen consumption in 5days (BOD5). But, determination of the ultimate biochemical oxygen demand (BODu), which is taken 28days and the reaction rate constant (k) are necessary to understand the organic strength of the wastewater. In this study, the different mathematical methods in order to determine the BOD parameters (BODu, k) and two different BOD test method (respirometer and dilution method) are investigated comparatively. Also, a new method based on cubic spline method to estimate ultimate BOD values is developed. Moreover, the impacts of BOD parameters on the design of an activated sludge and aerated lagoon systems are analyzed by using a written user-friend program, which is developed for designing WWTPs by the mean of C++ programming language.Analytical results show that there is a satisfactory linear relationship between respirometric and dilution BOD values. Also, the mathematical methods, including new developed method generally provide consistent results with high correlation coefficients. On the other hand, it is found that LOG differences method for respirometric test and the new developed method for dilution test do not give good correlation coefficients. Moreover, activated sludge and aerated lagoons systems' sizes show significant changing depending on the variations of the BOD parameters. Consequently, BOD parameters show significant changes depending on the different test and mathematical methods. Therefore, the changing of these parameters impact a lot of situation such as ultimate BOD estimation, the wastewater treatment plants design, the dimensions of the plants and cost of the plants.
dc.identifier.doi10.1016/j.apm.2013.07.013
dc.identifier.eissn1872-8480
dc.identifier.endpage658
dc.identifier.issn0307-904X
dc.identifier.issue2
dc.identifier.scopus2-s2.0-84890184319
dc.identifier.startpage641
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12052
dc.identifier.volume38
dc.identifier.wosWOS:000330487700017
dc.language.isoen
dc.publisherELSEVIER SCIENCE INC
dc.relation.ispartofApplied Mathematical Modelling
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectActivated sludge
dc.subjectAerated lagoon
dc.subjectBOD
dc.subjectC++ programming
dc.subjectMathematical modeling
dc.subjectWastewater
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationMathematics, Interdisciplinary Applications
dc.subject.classificationMechanics
dc.subject.classificationEngineering
dc.subject.classificationMathematics
dc.subject.otherBiochemical oxygen demand
dc.subject.otherComputer software
dc.subject.otherDesign
dc.subject.otherLakes
dc.subject.otherMathematical models
dc.subject.otherMathematical programming
dc.subject.otherRate constants
dc.subject.otherSewage pumping plants
dc.subject.otherWastewater
dc.subject.otherWater pollution
dc.subject.otherWater pollution control
dc.subject.otherWater treatment plants
dc.subject.otherActivated sludge
dc.subject.otherAerated lagoons
dc.subject.otherBiochemical oxygen demands (BOD)
dc.subject.otherC++ programming
dc.subject.otherCorrelation coefficient
dc.subject.otherLinear relationships
dc.subject.otherParameters variations
dc.subject.otherWastewater treatment plants
dc.subject.otherTesting
dc.titleThe comparison of different mathematical methods to determine the BOD parameters, a new developed method and impacts of these parameters variations on the design of WWTPs
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex24
rdl.citation.scopus20
rdl.citation.wos15
rdl.oa.statusbronze
rdl.oa.urlhttps://doi.org/10.1016/j.apm.2013.07.013
rdl.sdgSDG06
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)