Effect of micro-arc oxidation coatings with graphene oxide and graphite on osseointegration of titanium implants-an in vivo study

MakaleAçık Erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Background: This in vivo study evaluated the effect of graphene oxide and graphite coatings, coupled with the micro-arc oxidation (MAO) surface roughening technique, known for their mechanical strength, chemical stability, and antibacterial properties. The main objective was to assess the degree of improvement in osseointegration of titanium implants resulting from these interventions. Materials and methods: In this study, 32 female rats were utilized and randomly allocated into four groups (n = 8 each): machined surface titanium implants (control), those roughened by the MAO method, those coated with graphene oxide-doped MAO, and those with a graphite-doped MAO coating. Titanium implants were surgically placed in the right tibia of the rats. Rats undergoing no additional procedures during the 4-week experimental period were sacrificed at the end. Then, the implants and surrounding bone tissues were separated and embedded in acrylic blocks for reverse torque analysis. Using a digital torque device, the rotational force was applied to all samples using a hex driver and racquet until implant separation from the bone occurred, with the corresponding values recorded on the digital display. Then, statistical analysis was performed to analyze the data. Results: No statistically significant difference between the groups was observed in the biomechanical bone–implant connection levels (N/cm) (P = 0.268). Post-hoc tests were not required because no discernible differences were identified between the groups. Conclusion: Within the scope of this study, implants treated with the MAO method, along with those coated with graphene oxide- and graphite-doped MAO method, did not exhibit significant superiority in terms of osseointegration compared to machined surface titanium implants.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12000Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTekin, Bahar
dc.contributor.authorDundar, Serkan
dc.contributor.authorTekin, Samet
dc.contributor.authorEmine Sukuroglu, Ebru
dc.contributor.authorKhurshid, Zohaib
dc.contributor.authorEzgi, Yusuf
dc.contributor.authorDemirci, Fatih
dc.contributor.authorFaheemuddin, Muhammad
dc.date.accessioned2026-10-22T10:19:34.791546774Z
dc.date.available2026-10-22T10:19:34.791546774Z
dc.date.issued2024
dc.description.abstractBackground: This in vivo study evaluated the effect of graphene oxide and graphite coatings, coupled with the micro-arc oxidation (MAO) surface roughening technique, known for their mechanical strength, chemical stability, and antibacterial properties. The main objective was to assess the degree of improvement in osseointegration of titanium implants resulting from these interventions. Materials and methods: In this study, 32 female rats were utilized and randomly allocated into four groups (n = 8 each): machined surface titanium implants (control), those roughened by the MAO method, those coated with graphene oxide-doped MAO, and those with a graphite-doped MAO coating. Titanium implants were surgically placed in the right tibia of the rats. Rats undergoing no additional procedures during the 4-week experimental period were sacrificed at the end. Then, the implants and surrounding bone tissues were separated and embedded in acrylic blocks for reverse torque analysis. Using a digital torque device, the rotational force was applied to all samples using a hex driver and racquet until implant separation from the bone occurred, with the corresponding values recorded on the digital display. Then, statistical analysis was performed to analyze the data. Results: No statistically significant difference between the groups was observed in the biomechanical bone–implant connection levels (N/cm) (P = 0.268). Post-hoc tests were not required because no discernible differences were identified between the groups. Conclusion: Within the scope of this study, implants treated with the MAO method, along with those coated with graphene oxide- and graphite-doped MAO method, did not exhibit significant superiority in terms of osseointegration compared to machined surface titanium implants.
dc.description.sponsorshipFirat University Experimental Research Center, (2020/11)
dc.identifier.doi10.1016/j.sdentj.2024.01.013
dc.identifier.eissn1658-3558
dc.identifier.endpage595
dc.identifier.issn1013-9052
dc.identifier.issue4
dc.identifier.pmid38690378
dc.identifier.scopus2-s2.0-85184760369
dc.identifier.startpage591
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12000
dc.identifier.volume36
dc.identifier.wosWOS:001230812100001
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofSaudi Dental Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCoating
dc.subjectDental implants
dc.subjectGraphene oxide
dc.subjectGraphite
dc.subjectMicro-arc oxidation
dc.subjectOsseointegration
dc.subject.classificationDentistry, Oral Surgery & Medicine
dc.subject.othergraphene oxide
dc.subject.othergraphite
dc.subject.othertitanium
dc.subject.otheranimal experiment
dc.subject.otheranimal tissue
dc.subject.otherArticle
dc.subject.otherbiomechanics
dc.subject.otherbone tissue
dc.subject.othercoating (procedure)
dc.subject.otherfemale
dc.subject.otherin vivo study
dc.subject.othernonhuman
dc.subject.otherosseointegration
dc.subject.otheroxidation
dc.subject.otherpost hoc analysis
dc.subject.otherrat
dc.subject.othertibia
dc.subject.othertorque
dc.titleEffect of micro-arc oxidation coatings with graphene oxide and graphite on osseointegration of titanium implants-an in vivo study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex10
rdl.citation.scopus9
rdl.citation.wos8
rdl.departmentGumushane University, Faculty of Engineering and Natural Sciences, Department of Mechanical Engineering, Gumushane, Turkey
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.1016/j.sdentj.2024.01.013
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexEmerging Sources Citation Index (ESCI)