Effect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiency

MakaleYalnız künye

Özet

As well known, High Purity Germanium (HPGe) detectors have a wide range of applications in every area where radiation detection and measurements are involved. One of the most important parameters in this respect is the determination of the full energy peak (FEP) efficiency. There are certain parameters affecting the so-called FEP efficiency. Perhaps the most important one is the thickness of dead layers of the crystal itself. In the current study, we investigated the effects of the thickness of front, lateral and back dead layer thicknesses of the detector crystal on the FEP efficiencies for the energy range 30 keV–5 MeV using EGS4 Monte Carlo simulation package. It was shown that the change in the thickness of the front dead layer has significant effect on the efficiency values for the energy interval 30–400 keV. The change in the thickness of the lateral and back dead layer was shown to have significant effects on the efficiencies for the energy intervals 2–3 MeV and 3–5 MeV, respectively. The results were checked using GEANT4 and a good agreement was observed.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/11968Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.nima.2022.166401Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaya, Selim
dc.contributor.authorÇeli̇k, Necati
dc.contributor.authorBayram, Tuncay
dc.date.accessioned2026-10-22T10:19:32.757060017Z
dc.date.available2026-10-22T10:19:32.757060017Z
dc.date.issued2022
dc.description.abstractAs well known, High Purity Germanium (HPGe) detectors have a wide range of applications in every area where radiation detection and measurements are involved. One of the most important parameters in this respect is the determination of the full energy peak (FEP) efficiency. There are certain parameters affecting the so-called FEP efficiency. Perhaps the most important one is the thickness of dead layers of the crystal itself. In the current study, we investigated the effects of the thickness of front, lateral and back dead layer thicknesses of the detector crystal on the FEP efficiencies for the energy range 30 keV–5 MeV using EGS4 Monte Carlo simulation package. It was shown that the change in the thickness of the front dead layer has significant effect on the efficiency values for the energy interval 30–400 keV. The change in the thickness of the lateral and back dead layer was shown to have significant effects on the efficiencies for the energy intervals 2–3 MeV and 3–5 MeV, respectively. The results were checked using GEANT4 and a good agreement was observed.
dc.identifier.articlenumber166401
dc.identifier.doi10.1016/j.nima.2022.166401
dc.identifier.eissn1872-9576
dc.identifier.issn0168-9002
dc.identifier.scopus2-s2.0-85124796327
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/11968
dc.identifier.volume1029
dc.identifier.wosWOS:000783012200017
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCrystal dead layer
dc.subjectFEP efficiency
dc.subjectHPGe detector
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationNuclear Science & Technology
dc.subject.classificationPhysics, Nuclear
dc.subject.classificationPhysics, Particles & Fields
dc.subject.classificationPhysics
dc.subject.otherGermanium compounds
dc.subject.otherIntelligent systems
dc.subject.otherMonte Carlo methods
dc.subject.other'current
dc.subject.otherCrystal dead layer
dc.subject.otherDead layers
dc.subject.otherEnergy interval
dc.subject.otherEnergy ranges
dc.subject.otherFull-energy peak efficiencies
dc.subject.otherHigh-purity germanium detector
dc.subject.otherLayer thickness
dc.subject.otherRadiation detection
dc.subject.otherRadiation measurements
dc.subject.otherCrystals
dc.titleEffect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiency
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex36
rdl.citation.scopus31
rdl.citation.wos27
rdl.oa.statusclosed
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)