Constructal Placement of Discrete Heat Sources with Different Lengths in Vertical Ducts under Natural and Mixed Convection

MakaleYalnız künye
  • SDG 7 · Erişilebilir ve Temiz Enerji

Özet

In this study, convective heat transfer in a discretely heated parallel-plate vertical channel which simulates an IC package is investigated experimentally and numerically. Both natural and mixed convection cases are considered. The primary focus of the study is on determining optimum relative lengths of the heat sources in order to reduce the hot spot temperature and to maximize heat transfer from the sources to air. Various values of the length ratio and the modified Grashof number (for the natural convection case)/the Richardson number (for the mixed convection case) are examined. Conductive and radiative heat transfer is included in the analysis while air is used as the working fluid. Surface temperatures of the heat sources and the channel walls are measured in the experimental study. The numerical studies are performed using a commercial CFD code, ANSYS FLUENT. The variations of surface temperature, hot spot temperature, Nusselt number, and global conductance of the system are obtained for varying values of the working parameters. From the experimental studies, it is showed that the use of identical heat sources reduces the overall cooling performance both in natural and mixed convection. However, relatively decreasing heat sources lengths provides better cooling performance.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/11850Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1115/1.4041187Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSarper, Bugra
dc.contributor.authorSaglam, Mehmet
dc.contributor.authorAydin, Orhan
dc.date.accessioned2026-10-22T10:19:25.593608483Z
dc.date.available2026-10-22T10:19:25.593608483Z
dc.date.issued2018
dc.description.abstractIn this study, convective heat transfer in a discretely heated parallel-plate vertical channel which simulates an IC package is investigated experimentally and numerically. Both natural and mixed convection cases are considered. The primary focus of the study is on determining optimum relative lengths of the heat sources in order to reduce the hot spot temperature and to maximize heat transfer from the sources to air. Various values of the length ratio and the modified Grashof number (for the natural convection case)/the Richardson number (for the mixed convection case) are examined. Conductive and radiative heat transfer is included in the analysis while air is used as the working fluid. Surface temperatures of the heat sources and the channel walls are measured in the experimental study. The numerical studies are performed using a commercial CFD code, ANSYS FLUENT. The variations of surface temperature, hot spot temperature, Nusselt number, and global conductance of the system are obtained for varying values of the working parameters. From the experimental studies, it is showed that the use of identical heat sources reduces the overall cooling performance both in natural and mixed convection. However, relatively decreasing heat sources lengths provides better cooling performance.
dc.description.sponsorshipScientific and Technological Research Council of Tur-key
dc.description.sponsorshipTUBITAK, (114M589)
dc.identifier.articlenumber121401
dc.identifier.doi10.1115/1.4041187
dc.identifier.eissn1528-8943
dc.identifier.issn0022-1481
dc.identifier.issue12
dc.identifier.scopus2-s2.0-85054291333
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/11850
dc.identifier.volume140
dc.identifier.wosWOS:000449984500002
dc.language.isoen
dc.publisherAmerican Society of Mechanical Engineers (ASME)
dc.relation.ispartofJournal of Heat Transfer
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.classificationThermodynamics
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationEngineering
dc.subject.otherFLUSH-MOUNTED HEATERS
dc.subject.otherSURFACE RADIATION
dc.subject.otherFORCED-CONVECTION
dc.subject.otherHORIZONTAL CHANNEL
dc.subject.otherNUMERICAL-SIMULATION
dc.subject.otherELECTRONIC BOARD
dc.subject.otherSOURCE ARRAY
dc.subject.otherPLATE
dc.subject.otherCONJUGATE
dc.subject.otherFLOW
dc.titleConstructal Placement of Discrete Heat Sources with Different Lengths in Vertical Ducts under Natural and Mixed Convection
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex12
rdl.citation.scopus11
rdl.citation.wos11
rdl.oa.statusclosed
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)